background image

Safety

Water Pumps | Version 1.02

5

Only persons reliable working procedures can be ex-
pected from, are allowed to perform all works. Persons 
the responsiveness of which is affected by e. g. drugs, 
alcohol or medication, are not allowed to work with the 
machine.

The qualifications of the personnel for the different tasks 
are mentioned below:

Operator

The operator is instructed by the operating company 
about the assigned tasks and possible risks in case of 
improper behaviour. Any tasks which need to be per-
formed beyond the operation in the standard mode 
must only be performed by the operator if it is indicated 
in these instructions and if the operating company ex-
pressively commissioned the operator.

Electrically qualified person

Electrically qualified person is due to their professional 
training, knowledge and experience as well as knowl-
edge of the relevant standards and regulations, in a po-
sition to carry out work on the electrical systems and to 
in-dependently recognize and avoid possible dangers.

Qualified personnel

Due to their professional training, knowledge and expe-
rience as well as their knowledge of relevant regulations 
the specialist staff is able to perform the assigned tasks 
and to recognise and avoid any possible dangers them-
selves.

Manufacturer

Certain works may only be performed by specialist per-
sonnel of the manufacturer. Other personnel is not au-
thorized to perform these works. Please contact our cus-
tomer service for the execution of all arising work.

2.4 Personal protective equipment

The personal protective equipment serves to protect 
per-sons against impairments of safety and health while 
working. The staff member has to wear personal protec-
tive equipment while performing different tasks on and 
with the machine which are indicated in the individual 
paragraphs of these instructions.

The personal protective equipment is explained in the 
following paragraph:

2.5 General safety regulations

Please note the following:

-  Use the guards and secure them securely. Never 
work without guards and get them working.
-  Keep the machine and your work environment 
clean at all times. Ensure sufficient illumination.
-  The special Water pump design must not be 
changed; the machine must not be used for work 
not in-tended by the manufacturer.
-  Never work under the influence of illnesses that 

impair concentration, drugs, alcohol or medica-
tion.

- Only start the water pump as soon as the pump 

chamber has filled with water.

-  Keep children and persons unfamiliar with the 

special Water pump away from their work environ-
ment.

-  Do not use the mains cable to pull the plug out of 
the socket. Protect the cable against heat, oil and 
sharp edges.
-  Never use the power cord to move or lift the spe-

cial Water pump.

- Do not bend, crush, pull or drive over power cords 

and extension cords.

- Disruptions that affect safety are eliminated imme-

diately.

-  Before using the Water pump make sure that no 

parts are damaged. Replace damaged parts im-
mediately to avoid sources of danger!

- Never overload the Water pump! Working within 

the stated performance limits is better and safer.

- Do not expose the pump to rain.
- Do not use the pump in hazardous areas or near 

flammable liquids and gases.

- Do not touch the power plug with wet hands.

Protective goggles

The goggles protect the eyes from flying parts and 
liquid splashes.

Protective gloves

The protective gloves serve to protect the hands 
against sharp components as well as against fric-
tion, abrasions or deep injuries. 

Safety boots

Safety boots protect the feet from being crushed, 
falling parts and slipping over on slippery ground. 

Protective clothes

Protective clothes are made of a tightly fitted fabric 
without the protruding parts of low tear strength.

Summary of Contents for 7520100

Page 1: ...W ATER P UMPS Water pump SCWP 10013 Operating Instructions SCWP 7514 SCWP 10013 SDWP 7514 SDWP 10020 SDWP 7514 SDWP 10020 SCWP 7514 SPWP 1107 SPWP 1107...

Page 2: ...yright 3 1 2 Customer service 3 1 3 Limitation of liability 3 2 Safety 3 2 1 Symbol explanation 3 2 2 Obligations of the operating company 4 2 3 Requirements to staff 4 2 4 Personal protective equipme...

Page 3: ...r maschinen de We are always interested in valuable experience and knowledge gained from using the application which then could be shared and be valuable to develop our products even further 1 3 Limit...

Page 4: ...od this manual Furthermore she must instruct the staff in regular intervals and in form them about the hazards The operator must provide the necessary protec tive equipment to the staff and order the...

Page 5: ...the machine which are indicated in the individual paragraphs of these instructions The personal protective equipment is explained in the following paragraph 2 5 General safety regulations Please note...

Page 6: ...temperature is lower than 4 C or the pump is not used for a long time drain the piping system to prevent ice from forming in the pump chamber ATTENTION Place the cable so that it can not be sucked in...

Page 7: ...tact with parts and high voltage direct contact or with parts that are under high voltage due to a defect in the device in direct contact 4 Type plate Fig 2 Type plate SCWP 7514 ATTENTION Any change o...

Page 8: ...e head max m 9 11 5 8 10 5 42 Flow rate l min 233 216 233 325 116 Feed pressure bar Inlet outlet threat Inlet Outlet mm 25 32 25 32 25 32 38 1 25 4 Suction height m 7 7 7 7 7 Grain size max mm 5 5 30...

Page 9: ...ed on top of each other Also no other items may be parked on it Step1 Turn off the water pump and drain completely Wipe all accessible surfaces and let the water pump dry Step 2 Disconnect the suction...

Page 10: ...as those that occur in the sew ers or rainwater are pumped Because of its compact shape and good operability the electric pump can be used as a portable suction pump for gardening or other normal con...

Page 11: ...fting or mounting of a rope SPWP 1107 On certain models there is an outlet on the contact sur face between the pump body and the head cover It is a normal phenomenon for an electric pump that it re le...

Page 12: ...iderable damage It is therefore essen tial to seal the threaded parts of the cables with each other and the connection to the pump with Teflon tape Only the use of sealing material such as Teflon tape...

Page 13: ...l connection must be equipped with a high sensitive fault current circuit breaker RCCB 30 mA ATTENTION Only use an extension cable whose cross section and rubber sheathing correspond at least to the c...

Page 14: ...the disconnected water pump Always check the supply cable for damage such as cracks or signs of aging If necessary replace the cable before further use ATTENTION The replacement of a defective power c...

Page 15: ...the pump without pumping water must be avoided as lack of water will cause the pump to overheat This can lead to considerable damage to the device In addition there is very hot water in the system so...

Page 16: ...hat electrical devices contain a variety of recyclable materials as well as environmentally harmful components You contributes to that these components are disposed of separately and properly In case...

Page 17: ...e pump sucks in air B The pump runs continuously A Make sure the water supply water level is high enough When submerging immerse the pump in a slight angle B Set the float switch correctly Despite the...

Page 18: ...SCWP 7514 must be ordered The stator housing has the number 38 in the spare parts drawing 1 Type of device Water pump SCWP 7514 Item number 7520100 Drawing number 1 Position number 38 The order numbe...

Page 19: ...e parts drawing In case of service the following drawing shall help to identify the necessary spare parts If necessary send a copy of the parts drawing with the marked components to your authorised de...

Page 20: ...20 Water Pumps Version 1 02 Spare parts Fig 14 Spare parts drawing 2 Model SCWP 10013...

Page 21: ...Spare parts Water Pumps Version 1 02 21 Fig 15 Spare parts drawing 3 Model SDWP 7514...

Page 22: ...22 Water Pumps Version 1 02 Spare parts Fig 16 Spare parts drawing 4 Model SDWP 10020...

Page 23: ...Spare parts Water Pumps Version 1 02 23 Fig 17 Spare parts drawing 5 Model SPWP 1107...

Page 24: ...24 Water Pumps Version 1 02 Electrical wiring diagram 14 Electrical wiring diagram Fig 18 Electrical wiring diagram of the Model SCWP 7514 SCWP 10013 SDWP 7514 SDWP 10020 SPWP 1107...

Page 25: ...ex I to Council Directive 2014 30 EU Relevant EU Directives Following standards where applied EN 55014 1 2006 Al A2 Electromagnetic compatibility Requirements for household appliances electric tools a...

Page 26: ...www cleancraft de...

Reviews: