background image

PE 6001

DOUBLE SCISSOR LIFT 3T

RISKS FOR PERSONNEL

 

This manual illustrates potential risks for operators, maintenance fitters or any other person standing in 

the  area around the lift when an incorrect use of it is carried out. 

RISKS IN USING THE LIFT

 

During the up and down operations the personnel must stand within the safety area, following the rules 

and the instruction given by the manufacturer. 

During the up and down operations no one is allowed to work beneath the movable parts of the lift, but 

he has stand in the safety zone. 

RISK OF IMPACT (Picture 9) 

Before the operator begins up and down movements, make sure that there are no personnel inside the 

danger zone. When, 

due to operational reasons, the lift is stopped at relatively low elevations (lower than 1.75m above the 

ground) personnel 

must be careful to avoid impact with parts of the machine that are not marked with special colors. 

RISK OF FALLING OFF (PERSONNEL) 

During up and down operations personnel are prohibited from entering the platforms and the vehicle 

lifted to avoid falling off. 

RISK OF FALLING (VEHICLE) (Picture 10) 

This hazard may arise in the case of incorrect positioning of the vehicle on the platforms, overweight of 

the lifted vehicle, or in the case the vehicle dimensions are not compatible with the capacity of the lift. 

When the platform is being tested, the vehicle engine cannot be turned on. 

There is nothing that should be placed on the lift-lowering area and the movable parts of the lift. 

RISK OF SLIPPING (Picture 10) 

The area beneath and immediately surrounding the lift, or its platforms, must be kept clean. Remove any 

oil spills immediately. Keep Clean the working area. 

RISK OF ELECTRIC SHOCK

 

The risk of electric shock in the insulated areas is shattered. 

Do not use jets of water, steam solvents or paint next to the lift and take special care to keep such 

substances away from the electrical control panel. 

RISKS RELATED TO INAPPROPRIATE LIGHTING

 

The operator and the maintenance fitter must be able to assure that all of the lift areas are properly and 

uniformly illuminated, in the respect of the laws in force in the place of installation. 

During up and down operations the operator should constantly observe the lift movements and he can only 

operate it through the operator safety zone. The handling of safety devices is strictly forbidden. 

Never exceed the maximum carrying capacity and make sure that the lifted vehicle has no loads on board. 

It is also essential to adhere scrupulously to all of the regulations, maintenance and safety contained in this 

manual. 

Picture 9

Picture 10

Summary of Contents for PE 6001

Page 1: ...clas com DOUBLE SCISSOR LIFT 3T PE 6001...

Page 2: ...tions for use breakdown manufacturing problem please contact us Contact You can reach us by mail sav clas com or by phone 33 0 4 79 72 69 18 or go directly to our website clas com If you have changed...

Page 3: ...any other expense not specified in the supply contract are at the purchaser s charge The replacement and repair of parts under warranty anyway do not extend warranty terms The purchaser will neverthel...

Page 4: ...ded If finding missing parts possible defects or damages to the goods caused during the transport you should immediately inform the person in charge or the carrier The lifter is really heavy Don t mov...

Page 5: ...fting transport unpacking assembly installation starting up initial adjustment and testing extraordinary maintenance repair overhauls transport and dismantling of the lift are all operations that must...

Page 6: ...on doors Scissor lift is designed and built to lift all kinds of vehicles all other use are unauthorized In particular the lift is not suitable for washing spray work And do not lift vehicles whose we...

Page 7: ...Hydraulic oil Working temperature Working humidity Noise level Installation height Storage temperature Installation place PE 6001 Electrical hydraulic Hydraulic 3500kg 1950mm 105mm 1420mm 650mm 50s 6...

Page 8: ...PE 6001 DOUBLE SCISSOR LIFT 3T Lift dimension picture Picture 3...

Page 9: ...PE 6001 DOUBLE SCISSOR LIFT 3T Lift groundwork drawing for in ground installation Picture 4...

Page 10: ...f the lift platform nr P1 and nr P2 represents the concrete structure When the thickness of the inside level ground is less than 150mm the end of P1 and P2 should be taken to 2500 2500mm length and th...

Page 11: ...orms for personnel or lifting personnel Use as a press for crushing purposes Use as elevator Use as elevator for single parts of vehicles The manufacturer is not liable for any injury to persons or da...

Page 12: ...s that operators or maintenance fitters may be exposed to when the vehicle is standing on the platforms in its raised position together with the various safety and protection devices adopted by the ma...

Page 13: ...ght of the lifted vehicle or in the case the vehicle dimensions are not compatible with the capacity of the lift When the platform is being tested the vehicle engine cannot be turned on There is nothi...

Page 14: ...s it is perfectly leveled and sufficiently resistant 250 kg cm the thickness of concrete 150 mm All parts of the lift must be uniformly illuminated with enough light to make sure that the adjustment a...

Page 15: ...oil pipes be careful not to mistake the oil pipe Open the front cover on the control box Connection of power supply The three phase connection cables with 5 poles 400V 5 x 2 5 mm cable dimension are...

Page 16: ...te the MAIN SWITCH button to turn on the power by clicking the UP button proceed checking that the engine rotates clockwise by looking down if it s not turn off the MAIN SWITCH and then change the mot...

Page 17: ...leveling of the bases If the irregularity of the platforms is due to the irregularity of the bases use an iron thickness to level it After adjusting the level insert the anchor and use a hammer to se...

Page 18: ...o stop the process immediately Resolve the problem and repeat the test again Before any operation remove possible obstacles from the lifting area of the lift When lifting or lowering the platforms no...

Page 19: ...form press the EMERGENCY STOP button to stop the entire operating circuit and to interrupt any other operations HYDRAULIC OIL ADJUSTMENT normal conditions of use EMERGENCY PROCEDURE FOR PLATFORM MANUA...

Page 20: ...ower outlet The AC contactor does not work The limit switch is not closed The motor turns reverse Lifting with light load works normally but not with heavy load The hydraulic oil has a high viscosity...

Page 21: ...PE 6001 DOUBLE SCISSOR LIFT 3T Air circuit diagram only for mechanical lock version APPENDIX...

Page 22: ...PE 6001 DOUBLE SCISSOR LIFT 3T Hydraulic hose connection diagram APPENDIX...

Page 23: ...PE 6001 DOUBLE SCISSOR LIFT 3T Hydraulic diagram for the hydraulic lock version APPENDIX...

Page 24: ...PE 6001 DOUBLE SCISSOR LIFT 3T Electrical diagram 230V for the hydraulic lock version APPENDIX...

Page 25: ...PE 6001 DOUBLE SCISSOR LIFT 3T Electrical diagram 400V for the hydraulic lock version APPENDIX...

Page 26: ...ntactor thermal relay motor fuse power supply computer board power lamp emergency UP button DOWN button SEC DOWN button synchronization button photoelectric shield key switch buzzer descent valve work...

Page 27: ...PE 6001 DOUBLE SCISSOR LIFT 3T...

Page 28: ......

Page 29: ......

Page 30: ......

Page 31: ......

Page 32: ...parts please contact the reseller In case of problems please contact your authorized technician CLAS Equipements ZA de la CROUZA 73800 CHIGNIN FRANCE T l 33 0 4 79 72 62 22 Fax 33 0 4 79 72 52 86 PE 6...

Reviews: