PE 6001
DOUBLE SCISSOR LIFT 3T
ELECTRIC CIRCUIT CONNECTION:
Follow the line path stated in the ‘electrical diagram’ to connect electric circuit.
Only skilled persons are allowed to perform the operations.
Connection of the photocell
sensor (PH):
see the connection on the
circuit diagram.
OIL PIPE CONNECTION:
Follow the “oil pipe connection diagram “ to connect the oil pipes.
Only skilled and authorized personnel is allowed to pe rform the
operations.
Pay particularly attention to the oil pipe fitting protection.
Refer to the “oil pipe diagram” while:
connecting pipes, pay attention to the oil pipe joint protections
to prevent impurities from entering t he hydraulic cir cuit.
connecting the oil pipes, be careful not to mistake the oil pipe
Open the front cover on the control box.
Connection of power supply:
The three-phase connection cables with 5 poles 400V (5 x 2.5 mm- cable dimension) are connected
to the control box . The PE ground cable must be connected under the marked clamp and then
connected to the plugs of the two bases.
If the lift is operated at 230V three-phase, a different electrical diagram must be used. Request it
to the lift manufacturer.
If the lift is operated at 230V single-phase, a different electrical diagram must be used. Request it
to the lift manufacturer.
Connection of upper limit switch(SQ1): see the connection on the circuit diagram.
Connection of lower limit switch(SQ2): see the connection on the circuit diagram.
Picture 13 up limit switch
Picture 14 lower limit switch
Picture 16 (photocell sensor)
Picture 17
Picture 15 Limit switch positioning
Summary of Contents for PE 6001
Page 1: ...clas com DOUBLE SCISSOR LIFT 3T PE 6001...
Page 8: ...PE 6001 DOUBLE SCISSOR LIFT 3T Lift dimension picture Picture 3...
Page 9: ...PE 6001 DOUBLE SCISSOR LIFT 3T Lift groundwork drawing for in ground installation Picture 4...
Page 21: ...PE 6001 DOUBLE SCISSOR LIFT 3T Air circuit diagram only for mechanical lock version APPENDIX...
Page 22: ...PE 6001 DOUBLE SCISSOR LIFT 3T Hydraulic hose connection diagram APPENDIX...
Page 23: ...PE 6001 DOUBLE SCISSOR LIFT 3T Hydraulic diagram for the hydraulic lock version APPENDIX...
Page 24: ...PE 6001 DOUBLE SCISSOR LIFT 3T Electrical diagram 230V for the hydraulic lock version APPENDIX...
Page 25: ...PE 6001 DOUBLE SCISSOR LIFT 3T Electrical diagram 400V for the hydraulic lock version APPENDIX...
Page 27: ...PE 6001 DOUBLE SCISSOR LIFT 3T...
Page 28: ......
Page 29: ......
Page 30: ......
Page 31: ......