Test of load:
LIFTING:
DESCENT:
LOCK:
STOP FOR PLATFORM DISALIGMENT:
EMERGENCY STOP:
By Pressing the ‘UP’ button the platforms will rise. Platforms will stop climbing when
they reach the upper limit.
By Releasing the ‘UP’ button, the oil pump stops working and the platforms stop lifting.
By pressing the ‘DOWN’ button, the platforms will begin to descend.
By releasing the ‘DOWN’ button, the platforms will stop descending.
When the “DOWN” button is kept pressed, the platforms continue to descend
automatically, stopping at a high of about 330mm reaching the lower limit switch. By
releasing the “DOWN” button and pressing the “SEC. DOWN» button the platforms will
go down to their closing position.
Press the ‘SEC. DOWN’ button to lock the platform when the lift is in the required position.
When the platforms are not leveled, follow the process described in the next paragraph to
adjust the alignment. The lift can only be put into use after the two platforms have been
placed back at the same level.
If the lift has a malfunction while a vehicle is on the platform, press the «EMERGENCY STOP»
button to stop the entire operating circuit and to interrupt any other operations.
HYDRAULIC OIL ADJUSTMENT
(normal conditions of use):
EMERGENCY PROCEDURE FOR PLATFORM MANUAL LOWERING (POWER FAILURE):
After completing the installation process, the platform P1 is lower than the P2 one, this is due
to the air still present in the oil cylinder. When performing the “oil circuit setting operation”,
the lift must not be placed in operation and no weight have to be placed on the platform. The
adjustment process is shown at page 16.
During the manual lowering of the platforms observe the vehicle on
the deck until the operation is ended.
If anomalies occur during the process, immediately close the hydraulic
circuit safety valve.
The manual lowering process take place as follow:
You will notice that the platform will start to descend.
Place the «MAIN SWITCH» button on the “OFF” position (do not cut
off the power from the power supply).
Open the rear door of the control box and look for the valve figure 24.
Loosen slowly the RED final part of the oil valve.
Always check the correct floor leveling during lowering process.
After lowering the platforms immediately tighten the lower valve
screw.
The manual lowering process is now completed.
Summary of Contents for PE 6001
Page 1: ...clas com DOUBLE SCISSOR LIFT 3T PE 6001...
Page 8: ...PE 6001 DOUBLE SCISSOR LIFT 3T Lift dimension picture Picture 3...
Page 9: ...PE 6001 DOUBLE SCISSOR LIFT 3T Lift groundwork drawing for in ground installation Picture 4...
Page 21: ...PE 6001 DOUBLE SCISSOR LIFT 3T Air circuit diagram only for mechanical lock version APPENDIX...
Page 22: ...PE 6001 DOUBLE SCISSOR LIFT 3T Hydraulic hose connection diagram APPENDIX...
Page 23: ...PE 6001 DOUBLE SCISSOR LIFT 3T Hydraulic diagram for the hydraulic lock version APPENDIX...
Page 24: ...PE 6001 DOUBLE SCISSOR LIFT 3T Electrical diagram 230V for the hydraulic lock version APPENDIX...
Page 25: ...PE 6001 DOUBLE SCISSOR LIFT 3T Electrical diagram 400V for the hydraulic lock version APPENDIX...
Page 27: ...PE 6001 DOUBLE SCISSOR LIFT 3T...
Page 28: ......
Page 29: ......
Page 30: ......
Page 31: ......