AC 8000
AUTOMATIC AIR CONDITIONING STATION R1234yf
AC 8134
AUTOMATIC AIR CONDITIONING STATION R134a
30
1
High pressure gauge
For inspection and diagnosis of the A/C
system
2
Tank pressure gauge
For checking the pressure inside the gas
storage tank
3
Low pressure gauge
For system inspection/diagnosis and
vacuum control
4
Thermal printer
Prints a report of the cycles performed
5
LCD screen
Displays the unit's operations
6
Control buttons
Modify and select different menus
7
USB port
USB port for updating the internal database
8
Down" button
To scroll through the menus or decrease the
values of the different parameters
9
Up" button
To scroll through the menus or increase the
values of the different parameters
10
EXIT" button
Interrupt any operation, to exit and return to
the previous menu
11
ENTER" button
To select and validate the different functions
or to access the next menu
12
Hose storage
To place the instruction manual or the hoses
when not in use
13
Cylinder location
To store the new and drained oil and dye
14
Main 230V socket connector
To power the machine (220-240V 50 Hz)
15
Identification plate
Part number, serial number, year of
construction, ...
16
BP (blue) and HP (red) connections
To connect the BP / HP refill hoses to the
vehicle
17
Safety valve inspection door
To inspect the safety valve and the non-
condensable gas release valve
18
Vacuum pump ventilation grid
To vent and inspect the vacuum pump
19
New oil bottle
Oil storage / storage of oil for hybrid
vehicles, to be injected into the vehicle
20
Used oil bottle
Drained oil storage
21
Dye bottle OR hybrid oil bottle
OPTIONAL
Dye storage OR hybrid oil storage Hybrid oil
storage (OPTIONAL)
22
Non-condensable gas release valve
Automatically releases non-condensable
gases
23
Maximum pressure valve
Automatically releases pressure if the
maximum pressure is reached.