19
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
•
Check that the diffuser ring is not burned or cracked and that the airflow
holes are not obstructed. If damaged replace.
5. If the nozzle surface is oxidised, clean with extra fine abrasive paper. Check
wear of the plasma arc hole and the inner and outer surfaces. If the hole
has widened, or the nozzle is damaged in any way, replace it. The nozzle
“V” crater should be 1.5mm in depth.
COMPRESSED AIR FILTER
The unit is equipped with a filter for the compressed air which captures water
and oil vapour. The filter is fitted with a plunger for the manual draining of the
condensation. Periodically drain the water in the filter.
The air filter and air filter cartridge can only be replaced by a qualified service
engineer. Contact your nearest CLARKE service department.
STORAGE AND HANDLING
Store the machine in a dry location free from damp and humidity. Always
carry the machine by its handle and avoid straining the power cable, earth
cable or torch connector.
Summary of Contents for 6015700