18
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
MAINTENANCE
DO NOT open or dismantle the machine. Repairs must only be undertaken by
your CLARKE dealer.
Keep the machine clean by wiping with a soft cloth. DO NOT use abrasives.
Check that cables and leads are in good condition. If damaged, contact
your authorised service agent. Keep cables and leads clean. DO NOT use
solvents.
TORCH AND CABLE
These parts need no maintenance with the exception of a periodic inspection
and cleaning. All repairs should be carried out by a qualified service engineer.
•
DO NOT use solvents or strong detergents when cleaning.
•
If there is damage to the insulation such as breaks, cracks and burns or
even a loosening of electric conductors, the torch must not be used.
Manually dismantle the torch nozzle head.
To replace the consumable parts in
the torch:
1. Unscrew the shield cup from the
torch head assembly.
•
Clean the shield cup thoroughly
and replace if it is damaged
(burns, distortions or cracks). If in
any doubt, replace.
2. Remove the nozzle, gas diffuser
ring and electrode.
3. Fit a new nozzle, gas diffuser ring and electrode.
•
ALWAYS replace the nozzle, gas diffuser ring and electrode at the same
time.
4. Replace the shield cup and ensure that it is secure.
•
Check the build-up on the emitting surface of the electrode. When the
build-up is approximately 2mm replace the electrode.
CAUTION: BEFORE PERFORMING ANY MAINTENANCE ON THE PLASMA
CUTTER TURN OFF AT THE MAINS SOCKET AND LET ALL PARTS COOL
DOWN.