15
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
TROUBLESHOOTING
Problem
Possible Cause and Likely solution
Machine does
not function
when switched
on.
Tripped thermal
protection device.
Allow the machine to cool until the
yellow “Overheating” LED goes off,
then resume use. Reduce duration
of cutting periods to help reduce
load on the machine and tendency
to overheat.
Internal fuse
blown.
Return to your CLARKE dealer for
investigation.
Faulty power
switch
Return to your CLARKE dealer for
investigation.
Cutting not
stable
Loose torch cable
or earth clamp
cable.
Check that all connections are
tight.
Damaged torch
connection within
torch.
Return to your CLARKE dealer for
investigation.
Weak arc
strength
Incorrect line
voltage.
Have a qualified electrician
investigate the situation.
Arc does not
ignite
Poor ground
connection.
Make certain that the work piece
has a good connection with the
earth clamp using a clean surface
at the contact location.
Incorrectly sized or
excessively worn
nozzle.
Confirm that the nozzle is the
correct size for the torch used.
Check that the hole in the tip is not
deformed, enlarged or dirty.
Replace if required.