background image

保用條款

此保用提供德國寶產品之機件在正常使用下壹年保用
(自購買日起計算)。

Warranty Terms & Conditions

Under normal operations, the product will gurantee a 1-year full 

warranty provided by German Pool (effective from the date of 

purchase).

1. Customer who fails to present original purchase invoice will 

not be eligible for free warranty service.

2. Customer should always follow the operating    

 

instructions. This warranty does not apply to:

  -  labour costs for on-site installation, check-up, repair,    

  replacement of parts and other transportation costs;

  -  damages caused by accidents of any kind (including    

  material transfer and others); 

  -  operating failures resulting from applying incorrect voltage,  

   improper usage, and unauthorized installations  

 

  or repairs.

3. This warranty is invalid if:

  -  the purchase invoice is modified by an unauthorized party;

  -  the product is used for any commercial or industrial purposes;

  -  the product is repaired or modified by unauthorized    

  personnel, or unauthorized parts are installed;

  -  the serial number is modified, damaged or removed from  

   the  product.

4. German Pool will, at its discretion, repair or replace any    

defective part. 

5. This warranty will be void if there is any transfer of  

 

ownership from the original purchaser.

1. 未能出示購買發票正本者,將不獲免費維修服務。

2. 用戶應依照說明書的指示操作。本保用並不包括﹕
 

- 上門安裝、檢驗、維修或更換零件之人工以及

 

  一切運輸費用﹔

 

- 因天然與人為意外造成的損壞 (包括運輸及其他)﹔

 

- 電源接合不當、不依說明書而錯誤或疏忽使用本

 

  機所引致之損壞。

3. 於下列情況下,用戶之保用資格將被取消﹕
 

- 購買發票有任何非認可之刪改;

 

- 產品被用作商業或工業用途;

 

- 產品經非認可之技術人員改裝或加裝任何配件;

 

- 機身編號被擅自塗改、破壞或刪除。

4. 總代理有權選擇維修或更換配件或其損壞部份。

5. 產品一經被轉讓,其保用即被視作無效。

產品規格及設計如有變更,恕不另行通知。中英文版本如有出入,一概以英文版為準。本產品使用說明書以 www.germanpool.com 網上版為最新版本。

Specifications are subject to change without prior notice. If there is any inconsistency or ambiguity between the English version and the Chinese version, the 

English version shall prevail. Refer to www.germanpool.com for the most up-to-date version of the manual.

機身號碼

 Serial No. : 

購買商號

 Purchased From : 

發票號碼

 Invoice No. :  

購買日期

 Purchase Date :  

型號

 Model No. :

另請填妥以下表格並與正本發票一併保存,以便維修時核對資料。用戶提供之所有資料必須正確無誤,否則免費保用將會無效。

Please fill out the form below. This information and the original

 

purchase invoice will be required for any repairs. Warranty will be 

invalidated if information provided is found to be inaccurate. 

此 保 用 只 適 用 於 香 港 及 澳 門        

This warranty is valid only in Hong Kong and Macau

DSN

客戶服務及維修中心

Customer Service & Repair Centre

Hong Kong

10/F, Kowloon Godown
1-3 Kai Hing Road, Kowloon Bay, 
Kowloon, Hong Kong
Tel 

:  +852 2333 6249

Fax 

:  +852 2356 9798

Email  : [email protected]

Macau

3/F, Edificio Industrial Pou Fung, 
145 Rua de Francisco Xavier Pereira, 
Macau
Tel 

:  +853 2875 2699

Fax 

:  +853 2875 2661

香港

九龍灣啟興道1-3號

九龍貨倉10樓

電話:

+852 2333 6249

傳真:

+852 2356 9798

電郵:

[email protected]

澳門

澳門俾利喇街145號

寶豐工業大廈3樓

電話:

+853 2875 2699

傳真:

+853 2875 2661

*  

貴戶須在購機十天內,以下列其中一種方式向本公司
登記資料,保用手續方正式生效﹕

1) 

填妥本公司網頁內之
保用登記表格

 

    

www.germanpool.com/

warranty

2) 

填妥保用登記卡,
郵寄至本公司。

*  This warranty is not valid until customer registration information 

is received by our Service Centre within 10 days of purchase 

via one of the following means:

1)  Visit our website and register 

online:  

 

 

www.germanpool.com/

warranty

2) 

Complete all the fields on the 

attached Warranty Card and 

mail it back to our Customer 

Service Centre.

 

NOTE

Summary of Contents for GERMAN POOL DSN

Page 1: ...structions and warranty information carefully before use and keep them handy for future reference Online Warranty Registration U S E R M A N U A L DSN Instantaneous Electric Water Heater WH DSN M 20 1...

Page 2: ...ed to frost The values stated on the rating plate must be observed In case of malfunction disconnect the fuses immediately In case of leaks cut off the mains water supply instantly Repairs must only b...

Page 3: ...he devices must not be blocked and the water flow must not be restricted The water outlet facilities such as shower head jet control and other outlet unit must be decalcified regularly Deposits must b...

Page 4: ...load shedding relay for electronically controlled instantaneous water heaters refer to installing instructions This device complies with Directive 2014 53 EU Operation Instructions Note Carefully rea...

Page 5: ...e recorded by the appliance In order to use the Automatic function correctly according to the fill quantity it is there fore necessary to set the desired temperature on the appliance and only turn on...

Page 6: ...play and an alarm signal can be heard until the prompt is acknowledged by tapping on OK Operation Lock Secure your settings with a four digit PIN Note The operation lock can only be deactivated with t...

Page 7: ...es not suffice to heat the tapped quantity of water the control valve automatically reduces the flow rate so that the set temperature is reached How to Save Energy Set the exact temperature you need o...

Page 8: ...d by a firewall Protect the appliance against unauthorised access by using a secure Wi Fi pass word This should consist of letters numbers and special characters and should not be listed in the lexico...

Page 9: ...l restarts and check the function of the DSN If an update is not possible even after multiple attempts contact the after sales ser vice Use All functions described in chapter 3 How to use can also be...

Page 10: ...ased on Germany standard ie 400V 18kW 3 400 26A Actual wiring size based on EMSD Code Of Practice For Electricity wiring Regulation s Appendix A6 1 1 Maximum applicable cable size is 10mm2 in electric...

Page 11: ...diate proximity of metal surfaces to allow a reliable wireless connection and an optimal wireless range Dimensions in mm Based on Germany s guidelines a general test certificate concerning the evidenc...

Page 12: ...union nut and the inch seal onto the cold water connection 2 Screw the hot water connection piece with the union nut and the inch seal onto the hot water connection 5 Installation Installing the Appl...

Page 13: ...Then select the point Load shedding If the menu item is grayed out first activate the Expert Mode under Settings Software You can set a value of 0 1 or 2 bay tapping or The locking function must be ac...

Page 14: ...m Above S WARNING WARNING Before making the electrical connection fill the mains and the appliance with water by carefully opening and closing the hot water tap in order to vent completely To ensure a...

Page 15: ...the screw behind this cover and detach the hood 3 Close the shut off valve a in the cold water connection piece position closed 4 Unscrew the screw plug b from the cold water connection piece and take...

Page 16: ...33 34 34 37 37 37 37 37 37 38 38 3 Smart Control 39 39 39 40 Wi Fi 40 40 40 4 41 1 42 2 43 3 43 4 44 5 44 44 45 46 46 47 6 48 7 49 49 49 49 50 50 8 51 51 51 52 52 9 53 53 1 DSN 20 C 60 C DSN 70 C Dir...

Page 17: ...32 33 C 20 C 60 C 1 C 35 C 43 C 0 5 C 20 C 8 35 C 38 C 42 C 48 C 3 PIN Wi Fi CLAGE 2 MAIN MENU AUTOMATIC Duration 3 00 00 10 Fill Up 3 1 01 2...

Page 18: ...uage Currency HK C Temperature Limit 0 1 2 2 Operation Lock PIN PIN PIN PIN PIN 0 9 4 OK PIN OK PIN Protected Sections PIN PIN PIN PIN PIN PIN Brightness 5 100 0 100 0 1 5 Sound Load Shedding Expert M...

Page 19: ...low Limit 8 4 5 25 9 0 8 Factory Settings Synchronize Statistics Devices Wi Fi DSN 4 CLAGE Smart Control Software Info 2 USER 8 SAVINGS HK P 34 HK kWh HK m 35 C 38 C 42 C 48 C 8 INFO DEVICE INFORMATIO...

Page 20: ...Store Google Play Store CLAGE Smart Control 3 DSN Wi Fi Device DSN Advanced Client Accesspoint 1 Network SSID SSID 2 Wi Fi Apply 3 DSN Wi Fi 4 Smart Control DSN 5 Smart Control Device DSN Connect DSN...

Page 21: ...8215 info germanpool com 3 Smart Control SOFTWARE UPDATE Smart Control DSN iOS Apple App Store Update Smart Control Android OS Google Play Store Smart Control DSN DSN DSN Wi Fi 1 2 DSN 3 4 3 5 DSN Use...

Page 22: ...C 3 PE 400V AC 1 4 0mm2 4 0mm2 6 0mm2 6 0mm2 2 t 28 K t 38 K 9 2 6 8 10 7 7 9 12 3 9 0 13 8 10 2 0 4l 1 0MPa 10bar IES 15 1100 cm 90mS m 70 C 1 5l min automatic 3 0 08bar at 1 5l min 1 3bar at 9 0l mi...

Page 23: ...00 170 468 363 56 96 239 Dimensions in mm 5 16952 mm e g VDE 0100 EN 806 VDE 0100 part 701 IEC 60364 7 IP25 1 DIN 16893 Series 2 15 1 100 cm RDX3 36100 RDX IP25 IP24 VDX 34120 RDX UDX 34110 RDX 5 RDX3...

Page 24: ...46 47 2 1 12 12 14 2 6 3 4 30 1 1 2 2 1 2 5 a closed open 1 3 1 2 3 3 8 3 8 4 a 5 5 600x600...

Page 25: ...48 49 6 1 2 1 2 1 2 1 2 D 3 8 3 8 6 1 2 1 2 1 2 7 1 2 5 3 4 e g VDE 0100 IEC 3 C L2 x 0 1 2 x x 7 0 1 2 1 35 C 2 1 2 3 4 5...

Page 26: ...50 51 A 7 S 1 6 2 3 4 A 5 1 S 2 3 4 5 6 7 8 9 IP25 8 SDB STB MPS 27kW 400V 24kW 21kW 18kW 1 Approved DIN VDE0100 1 2 3 18 21 24 27kW 4 OK 5 6 10 30 7 8 9 EN60900...

Page 27: ...52 53 8 Pos OFF Pos 1 55 C 55 C 55 C 1 2 3 1 4 1 2 OFF 3 9 a closed open c b Strainer 1 2 3 a 4 b c 5 6 7 8 9 1 2 3 4 5 6 7 8 9...

Page 28: ...l purchaser 1 2 3 4 5 www germanpool com Specifications are subject to change without prior notice If there is any inconsistency or ambiguity between the English version and the Chinese version the En...