STATISTICS

The statistics save the consumption and usage data for the appliance and display them 

in graph format:
     Water consumption
     Power consumption
     Total consumption costs
Swipe from right to the left to scroll the different periods. The consumptions are 

displayed consecutively in diagrams over a period from the last drawing of water, the 

consumption today, the consumption yesterday, over the last seven days, the last four 

weeks, the last twelve months and the last four years.

Note: The consumption data are not suitable for billing purposes.

2. How To Use

SETTINGS

This menu is used for the basic configuration on the appliance. Swipe to scroll through 

the different menu items and tap on the values to change settings directly or go to dif-

ferent submenus.
 

Date / Time:

 The DSN automatically receives its system time as soon as the device 

is connected to a network with Internet access. Alternatively, you can set the time 

manually and save it by tapping on “Save Date and Time”. The time and date are lost in 

the event of a power failure if there is no network connection.
 

Language: 

Select the menu language.

 

Currency:

 Select a currency symbol (HK$).

 

Temperature Unit:

 Defined as °C.

 

Temperature Limit:

 The temperature limit can be activated / deactivated in this menu 

and the maximum outlet temperature can be limited to a desired value within the tem-

perature setting range by tapping on   or  .

Note: If the instantaneous water heater supplies a shower, then the maximum tem-

perature was limited during the installation of the appliance and can only be changed 

below this temperature. The Temperature Limit cannot be fully deactivated in this 

case.

When the fill quantity is reached, “0 l” flashes briefly on the display and the appliance 

stops the water flow by closing the motor valve. A long acoustic signal can also be 

heard and an instruction message appears on the display. The motor valve stay closed 

until the message is confirmed at the appliance or via app. 

Turning off the tap is always necessary, the function must therefore not be used unsu-

pervised.  

Before using the bath, make sure that the water temperature is what you want it to be.

Hint:

 The water amount of the last draw-off is stored in the “Statistics” menu. To 

determine the necessary amount of water for your bathtub, fill it with warm water, 

then select “Statistics” in the main menu and read out the value of this last drawing. 

Enter this value in the automatic function “Fill-Up” to use it for the next bathtub filling.

Note: In the event of a power cut whilst the automatic is running according to the 

fill quantity, the water flow is stopped by the motor valve. After power is restored 

the valve remains closed a prompt appears on the display and an alarm signal can be 

heard until the prompt is acknowledged by tapping on “OK”.

Operation Lock: 

Secure your settings with a four-digit PIN.

Note: The operation lock can only be deactivated with the correct PIN under 

“Protected Sections” or under “Delete PIN”. If you should forget your PIN, please 

contact after-sales Services.

Enter PIN: Numbers from 0 to 9 can be selected via the keypad. If you have selected 

four digits, confirm by tapping on “

OK

”. The PIN must then be entered again and con-

firmed for security reasons. 
If both entries match, you access the section “Protected Sections”.

Protected Sections: Select the areas for a PIN lock.
•  Lock Settings: Automatically active as soon as a password has been generated. 

Users can only access the settings menu with a PIN. Deactivating it deletes the cur-

rent PIN.

•  + Lock Main Menu: Users can only access the main menu with a PIN
•  + Lock Temperature: The outlet temperature is set to the current value and can only 

be changed with a PIN. User profiles, applications and Eco mode can also only be 

changed with a PIN.

 

Brightness: 

Reduce the display brightness e.g. to safe energy. The brightness can be 

set separately for operation screen and standby mode.
•  Operation 5-100%
•  Standby  0-100% (0% = display OFF)
The setting of the standby mode will be activated after 1.5 minutes.
 

Sound:

 Activate / deactivate operating sounds. 

Note: Alarm signals and instruction sounds cannot be disabled.
 

Load Shedding (Expert Mode):

 If further three-phase appliances are connected, a load 

shedding relay designed for electronic instantaneous water heaters (Art no. 82250) 

can be connected to phase conductor L2. This relay ensures the operation of the water 

heater by switching off other appliances until the end of heating operation.
Tap on   or   and hold for two seconds to set a value of 0, 1 or 2.
Operating mode 1 must be selected first, thus to check the correct operation of the 

load shedding relay at low appliance output (35 degree celsius setpoint and low water 

flow rate). Mode 2 must be selected if the load shedding relay flickers.

 

Thermal Treatment:

 With this function, you can support a thermal treatment of your 

appliance and the following pipeline, including the tap. A thermal disinfection accord-

ing to the accepted rules of technology is not replaced.
•  Tap OK to start the treatment cycle and the outlet temperature is set to 70 °C. The 

function is disabled if the appliance is connected to a shower.

•  Draw hot water for at least three minutes to heat the pipes to the tap completely.
•  A change of the temperature or 30 sec without water flow terminates the treat-

ment cycle.

•  The number as well as the accumulated duration and the water amount of all ther-

mal treatments will be saved and can be viewed under “Info”.

Value Description 

0 Operation without load shedding 

relay, factory setting

1

Operation with normal  

load shedding relay

2 Operation with sensitive 

load shedding relay

2. How To Use

Summary of Contents for GERMAN POOL DSN

Page 1: ...structions and warranty information carefully before use and keep them handy for future reference Online Warranty Registration U S E R M A N U A L DSN Instantaneous Electric Water Heater WH DSN M 20 1...

Page 2: ...ed to frost The values stated on the rating plate must be observed In case of malfunction disconnect the fuses immediately In case of leaks cut off the mains water supply instantly Repairs must only b...

Page 3: ...he devices must not be blocked and the water flow must not be restricted The water outlet facilities such as shower head jet control and other outlet unit must be decalcified regularly Deposits must b...

Page 4: ...load shedding relay for electronically controlled instantaneous water heaters refer to installing instructions This device complies with Directive 2014 53 EU Operation Instructions Note Carefully rea...

Page 5: ...e recorded by the appliance In order to use the Automatic function correctly according to the fill quantity it is there fore necessary to set the desired temperature on the appliance and only turn on...

Page 6: ...play and an alarm signal can be heard until the prompt is acknowledged by tapping on OK Operation Lock Secure your settings with a four digit PIN Note The operation lock can only be deactivated with t...

Page 7: ...es not suffice to heat the tapped quantity of water the control valve automatically reduces the flow rate so that the set temperature is reached How to Save Energy Set the exact temperature you need o...

Page 8: ...d by a firewall Protect the appliance against unauthorised access by using a secure Wi Fi pass word This should consist of letters numbers and special characters and should not be listed in the lexico...

Page 9: ...l restarts and check the function of the DSN If an update is not possible even after multiple attempts contact the after sales ser vice Use All functions described in chapter 3 How to use can also be...

Page 10: ...ased on Germany standard ie 400V 18kW 3 400 26A Actual wiring size based on EMSD Code Of Practice For Electricity wiring Regulation s Appendix A6 1 1 Maximum applicable cable size is 10mm2 in electric...

Page 11: ...diate proximity of metal surfaces to allow a reliable wireless connection and an optimal wireless range Dimensions in mm Based on Germany s guidelines a general test certificate concerning the evidenc...

Page 12: ...union nut and the inch seal onto the cold water connection 2 Screw the hot water connection piece with the union nut and the inch seal onto the hot water connection 5 Installation Installing the Appl...

Page 13: ...Then select the point Load shedding If the menu item is grayed out first activate the Expert Mode under Settings Software You can set a value of 0 1 or 2 bay tapping or The locking function must be ac...

Page 14: ...m Above S WARNING WARNING Before making the electrical connection fill the mains and the appliance with water by carefully opening and closing the hot water tap in order to vent completely To ensure a...

Page 15: ...the screw behind this cover and detach the hood 3 Close the shut off valve a in the cold water connection piece position closed 4 Unscrew the screw plug b from the cold water connection piece and take...

Page 16: ...33 34 34 37 37 37 37 37 37 38 38 3 Smart Control 39 39 39 40 Wi Fi 40 40 40 4 41 1 42 2 43 3 43 4 44 5 44 44 45 46 46 47 6 48 7 49 49 49 49 50 50 8 51 51 51 52 52 9 53 53 1 DSN 20 C 60 C DSN 70 C Dir...

Page 17: ...32 33 C 20 C 60 C 1 C 35 C 43 C 0 5 C 20 C 8 35 C 38 C 42 C 48 C 3 PIN Wi Fi CLAGE 2 MAIN MENU AUTOMATIC Duration 3 00 00 10 Fill Up 3 1 01 2...

Page 18: ...uage Currency HK C Temperature Limit 0 1 2 2 Operation Lock PIN PIN PIN PIN PIN 0 9 4 OK PIN OK PIN Protected Sections PIN PIN PIN PIN PIN PIN Brightness 5 100 0 100 0 1 5 Sound Load Shedding Expert M...

Page 19: ...low Limit 8 4 5 25 9 0 8 Factory Settings Synchronize Statistics Devices Wi Fi DSN 4 CLAGE Smart Control Software Info 2 USER 8 SAVINGS HK P 34 HK kWh HK m 35 C 38 C 42 C 48 C 8 INFO DEVICE INFORMATIO...

Page 20: ...Store Google Play Store CLAGE Smart Control 3 DSN Wi Fi Device DSN Advanced Client Accesspoint 1 Network SSID SSID 2 Wi Fi Apply 3 DSN Wi Fi 4 Smart Control DSN 5 Smart Control Device DSN Connect DSN...

Page 21: ...8215 info germanpool com 3 Smart Control SOFTWARE UPDATE Smart Control DSN iOS Apple App Store Update Smart Control Android OS Google Play Store Smart Control DSN DSN DSN Wi Fi 1 2 DSN 3 4 3 5 DSN Use...

Page 22: ...C 3 PE 400V AC 1 4 0mm2 4 0mm2 6 0mm2 6 0mm2 2 t 28 K t 38 K 9 2 6 8 10 7 7 9 12 3 9 0 13 8 10 2 0 4l 1 0MPa 10bar IES 15 1100 cm 90mS m 70 C 1 5l min automatic 3 0 08bar at 1 5l min 1 3bar at 9 0l mi...

Page 23: ...00 170 468 363 56 96 239 Dimensions in mm 5 16952 mm e g VDE 0100 EN 806 VDE 0100 part 701 IEC 60364 7 IP25 1 DIN 16893 Series 2 15 1 100 cm RDX3 36100 RDX IP25 IP24 VDX 34120 RDX UDX 34110 RDX 5 RDX3...

Page 24: ...46 47 2 1 12 12 14 2 6 3 4 30 1 1 2 2 1 2 5 a closed open 1 3 1 2 3 3 8 3 8 4 a 5 5 600x600...

Page 25: ...48 49 6 1 2 1 2 1 2 1 2 D 3 8 3 8 6 1 2 1 2 1 2 7 1 2 5 3 4 e g VDE 0100 IEC 3 C L2 x 0 1 2 x x 7 0 1 2 1 35 C 2 1 2 3 4 5...

Page 26: ...50 51 A 7 S 1 6 2 3 4 A 5 1 S 2 3 4 5 6 7 8 9 IP25 8 SDB STB MPS 27kW 400V 24kW 21kW 18kW 1 Approved DIN VDE0100 1 2 3 18 21 24 27kW 4 OK 5 6 10 30 7 8 9 EN60900...

Page 27: ...52 53 8 Pos OFF Pos 1 55 C 55 C 55 C 1 2 3 1 4 1 2 OFF 3 9 a closed open c b Strainer 1 2 3 a 4 b c 5 6 7 8 9 1 2 3 4 5 6 7 8 9...

Page 28: ...l purchaser 1 2 3 4 5 www germanpool com Specifications are subject to change without prior notice If there is any inconsistency or ambiguity between the English version and the Chinese version the En...

Page 29: ...Guangdong 3 F Edificio Industrial Pou Fung 145 Rua de Francisco Xavier Pereira Macau Tel Fax 853 2875 2699 853 2875 2661 Macau All rights reserved Copying reproducing or using the contents of this ma...

Reviews: