background image

12

13

2. How To Use

Notes:  

Ensure that no one can be injured by the elevated temperatures and that the installa-

tion can withstand the strain.
The exiting water and the tap become very hot! The water steam should not be 

inhaled.
 

Flow Limit:

 Setting of flow rate limitation.

Setting options:
“OFF” 

no flow rate limitation (motor valve deactivated)

“AUTO”  automatic adjustment, i.e. flow rate is limited in a way so that the selected 

outlet temperature is reached

“ECO” 

flow rate limitation to max. 8.0 l/min

e.g. “9.0” limitation to a freely selectable value between 4.5 and 25 l/min

Note: If the Eco function has been activated in the menu “Savings”, the flow is auto-

matically set to “ECO”. Changing the flow to a higher value than 8 l/min deactivates 

the Eco function
 

Factory Settings:

 All factory settings can be recalled:

•  Restart Device: Set the temperature back to factory setting and restart the appli-

ance.

•  Factory Reset: Deletes all entries made by the user inclusive statistics. 
 

Synchronize Statistics:

 Use this function to reload the statistical data.

 

Devices: 

All settings for operation with the app and for integrating the DSN into a 

Wi-Fi network are made here. For more information, see chapter: “4. CLAGE app 

Smart Control”.
 

Software Info

: Information about the operating system, the imprint and licenses can 

be viewed here. The 

“Expert Mode”

 can also be activated here. In the Expert Mode 

you have access to sensitive system settings and functions.

INFO/DEVICE INFORMATION

The current status and appliance data is listed here. By wiping you can scroll through 

the different information values. 

2. How To Use

Power limit

If the full output of the instantaneous water heater DSN does not suffice to heat the 

tapped quantity of water, the control valve automatically reduces the flow rate so that 

the set temperature is reached.

How to Save Energy

Set the exact temperature you need on the appliance and open the hot water tap. 

Once you feel that the water is too hot, do not add any cold water and, instead, enter 

a lower temperature on the appliance. If you were to add cold water, the water already 

heated would cool down again and valuable energy would be wasted. Moreover, the 

cold water added in the tap is not covered by the control range of the electronic cir-

cuitry, with the result that temperature constancy is no longer guaranteed.

SAVINGS

Here, you can determine the parameters for the costs in the consumption statistics 

and activate / deactivate the ECO Mode. You can select a currency symbol under 

“Settings”(P.9).

Electricity Tariff (HK$/kWh):

 Indicate the electricity price from your electricity com-

pany.

Water Tariff (HK$/m³):

 Indicate the water price from your water company.

ECO Settings:

 In Eco mode the outlet temperatures are limited to an energy-efficient 

value (  handwash = 35 °C,   shower = 38 °C,   bath = 42 °C,  

 hot water = 48 °C).

Additionally the water flow is limited to 8 l/min.

USER

Up to eight users can enter their names and select their own profile image. This 

appears together with the first letters of the name in the main screen.
In the main control, every user can set up and save his own desired temperatures for 

the different applications.
Tap the 

+

 symbol to add more profiles, use the pen to edit existing profiles and tap the 

×

 symbol to delete the adjacent user profile.

Top-up Heating

When operating with preheated water (e.g. with solar systems), you must ensure that 

the inlet temperature does not exceed 70 °C.
If the inlet temperature exceeds the setpoint, the appliance is not providing any out-

put. The symbol   is displayed in the main screen

Summary of Contents for GERMAN POOL DSN

Page 1: ...structions and warranty information carefully before use and keep them handy for future reference Online Warranty Registration U S E R M A N U A L DSN Instantaneous Electric Water Heater WH DSN M 20 1...

Page 2: ...ed to frost The values stated on the rating plate must be observed In case of malfunction disconnect the fuses immediately In case of leaks cut off the mains water supply instantly Repairs must only b...

Page 3: ...he devices must not be blocked and the water flow must not be restricted The water outlet facilities such as shower head jet control and other outlet unit must be decalcified regularly Deposits must b...

Page 4: ...load shedding relay for electronically controlled instantaneous water heaters refer to installing instructions This device complies with Directive 2014 53 EU Operation Instructions Note Carefully rea...

Page 5: ...e recorded by the appliance In order to use the Automatic function correctly according to the fill quantity it is there fore necessary to set the desired temperature on the appliance and only turn on...

Page 6: ...play and an alarm signal can be heard until the prompt is acknowledged by tapping on OK Operation Lock Secure your settings with a four digit PIN Note The operation lock can only be deactivated with t...

Page 7: ...es not suffice to heat the tapped quantity of water the control valve automatically reduces the flow rate so that the set temperature is reached How to Save Energy Set the exact temperature you need o...

Page 8: ...d by a firewall Protect the appliance against unauthorised access by using a secure Wi Fi pass word This should consist of letters numbers and special characters and should not be listed in the lexico...

Page 9: ...l restarts and check the function of the DSN If an update is not possible even after multiple attempts contact the after sales ser vice Use All functions described in chapter 3 How to use can also be...

Page 10: ...ased on Germany standard ie 400V 18kW 3 400 26A Actual wiring size based on EMSD Code Of Practice For Electricity wiring Regulation s Appendix A6 1 1 Maximum applicable cable size is 10mm2 in electric...

Page 11: ...diate proximity of metal surfaces to allow a reliable wireless connection and an optimal wireless range Dimensions in mm Based on Germany s guidelines a general test certificate concerning the evidenc...

Page 12: ...union nut and the inch seal onto the cold water connection 2 Screw the hot water connection piece with the union nut and the inch seal onto the hot water connection 5 Installation Installing the Appl...

Page 13: ...Then select the point Load shedding If the menu item is grayed out first activate the Expert Mode under Settings Software You can set a value of 0 1 or 2 bay tapping or The locking function must be ac...

Page 14: ...m Above S WARNING WARNING Before making the electrical connection fill the mains and the appliance with water by carefully opening and closing the hot water tap in order to vent completely To ensure a...

Page 15: ...the screw behind this cover and detach the hood 3 Close the shut off valve a in the cold water connection piece position closed 4 Unscrew the screw plug b from the cold water connection piece and take...

Page 16: ...33 34 34 37 37 37 37 37 37 38 38 3 Smart Control 39 39 39 40 Wi Fi 40 40 40 4 41 1 42 2 43 3 43 4 44 5 44 44 45 46 46 47 6 48 7 49 49 49 49 50 50 8 51 51 51 52 52 9 53 53 1 DSN 20 C 60 C DSN 70 C Dir...

Page 17: ...32 33 C 20 C 60 C 1 C 35 C 43 C 0 5 C 20 C 8 35 C 38 C 42 C 48 C 3 PIN Wi Fi CLAGE 2 MAIN MENU AUTOMATIC Duration 3 00 00 10 Fill Up 3 1 01 2...

Page 18: ...uage Currency HK C Temperature Limit 0 1 2 2 Operation Lock PIN PIN PIN PIN PIN 0 9 4 OK PIN OK PIN Protected Sections PIN PIN PIN PIN PIN PIN Brightness 5 100 0 100 0 1 5 Sound Load Shedding Expert M...

Page 19: ...low Limit 8 4 5 25 9 0 8 Factory Settings Synchronize Statistics Devices Wi Fi DSN 4 CLAGE Smart Control Software Info 2 USER 8 SAVINGS HK P 34 HK kWh HK m 35 C 38 C 42 C 48 C 8 INFO DEVICE INFORMATIO...

Page 20: ...Store Google Play Store CLAGE Smart Control 3 DSN Wi Fi Device DSN Advanced Client Accesspoint 1 Network SSID SSID 2 Wi Fi Apply 3 DSN Wi Fi 4 Smart Control DSN 5 Smart Control Device DSN Connect DSN...

Page 21: ...8215 info germanpool com 3 Smart Control SOFTWARE UPDATE Smart Control DSN iOS Apple App Store Update Smart Control Android OS Google Play Store Smart Control DSN DSN DSN Wi Fi 1 2 DSN 3 4 3 5 DSN Use...

Page 22: ...C 3 PE 400V AC 1 4 0mm2 4 0mm2 6 0mm2 6 0mm2 2 t 28 K t 38 K 9 2 6 8 10 7 7 9 12 3 9 0 13 8 10 2 0 4l 1 0MPa 10bar IES 15 1100 cm 90mS m 70 C 1 5l min automatic 3 0 08bar at 1 5l min 1 3bar at 9 0l mi...

Page 23: ...00 170 468 363 56 96 239 Dimensions in mm 5 16952 mm e g VDE 0100 EN 806 VDE 0100 part 701 IEC 60364 7 IP25 1 DIN 16893 Series 2 15 1 100 cm RDX3 36100 RDX IP25 IP24 VDX 34120 RDX UDX 34110 RDX 5 RDX3...

Page 24: ...46 47 2 1 12 12 14 2 6 3 4 30 1 1 2 2 1 2 5 a closed open 1 3 1 2 3 3 8 3 8 4 a 5 5 600x600...

Page 25: ...48 49 6 1 2 1 2 1 2 1 2 D 3 8 3 8 6 1 2 1 2 1 2 7 1 2 5 3 4 e g VDE 0100 IEC 3 C L2 x 0 1 2 x x 7 0 1 2 1 35 C 2 1 2 3 4 5...

Page 26: ...50 51 A 7 S 1 6 2 3 4 A 5 1 S 2 3 4 5 6 7 8 9 IP25 8 SDB STB MPS 27kW 400V 24kW 21kW 18kW 1 Approved DIN VDE0100 1 2 3 18 21 24 27kW 4 OK 5 6 10 30 7 8 9 EN60900...

Page 27: ...52 53 8 Pos OFF Pos 1 55 C 55 C 55 C 1 2 3 1 4 1 2 OFF 3 9 a closed open c b Strainer 1 2 3 a 4 b c 5 6 7 8 9 1 2 3 4 5 6 7 8 9...

Page 28: ...l purchaser 1 2 3 4 5 www germanpool com Specifications are subject to change without prior notice If there is any inconsistency or ambiguity between the English version and the Chinese version the En...

Page 29: ...Guangdong 3 F Edificio Industrial Pou Fung 145 Rua de Francisco Xavier Pereira Macau Tel Fax 853 2875 2699 853 2875 2661 Macau All rights reserved Copying reproducing or using the contents of this ma...