background image

18

19

Connecting pipe

Power circuit board cover

Power circuit board

Transmission module

Touch display incl. control panel 

support

Connecting terminal

Frame

Cold water connection

Fine filter

Water splash protection sleeve

Grommet

Screw-in nipples ½ inch

DSN hood

Non-return valve

Flow sensor

Thermal sensor

Thermal sensor

 

Outlet pipe

Bottom part  

incl. leakage sensor

Wall bracket

Hot water connection

1. Overview

Safety thermal cut-out

(STB)

Heating element 

Inlet pipe

Servomotor

Servomotor electronics

Installation Instruction

Safety pressure cut-out

(SDB)

Model

DSN

Energy efficiency class

A *

)

Rated capacity / rated current

18 kW..27 kW (26 A..39 A)

#

Chosen capacity / current

18 kW / 26 A

21 kW / 30 A

24 kW / 35 A

27 kW / 39 A

Electrical connection

3~ / PE 380..415 V AC

3~ / PE 400 V AC

Min. required cable size 

1) ^

4.0 mm

2

4.0 mm

2

6.0 mm

2

6.0 mm

2

Hot water (l/min) 

2)

max. at ∆t = 28 K

max. at ∆t = 38 K

9.2

6.8

10.7

7.9

12.3

9.0

13.8

10.2

Rated volume

0.4 l

Rated pressure

1.0 MPa (10 bar)

Connecting type

pressure-resistant / pressureless

Heating system

Bare wire heating system IES

®

@ 15 °C:

Required spec. water resistance  

Spec. electrical conductivity

≥ 1100 Ωcm

≤ 90 mS/m

Inlet temperature

≤ 70 °C

Switch on – max. flow rate

1.5 l/min – automatic 

3)

Pressure loss

0.08 bar at 1.5 l/min     1.3 bar at 9.0 l/min

Temperature range

20 – 60 °C [70 °C]

Water connection

G ½ inch

Weight (when filled with water)

4.5 kg

VDE class of protection

I

Type of protection / safety

IP25

*) The declaration complies with the EU regulation No 812/2013.

# Rated current is provided based on Germany standard, ie. 400V, 18kW/√3/400=26A

^ Actual wiring size based on EMSD Code Of Practice For Electricity (wiring) Regulation’s Appendix A6(1)

1) Maximum applicable cable size is 10 mm

2

 in electrical connection from above. 

2) Mixed water

3) Electronically controlled depending on the desired temperature and cold water temperature

2. Technical Specifications

Your product was manufactured from high-quality, reusable materials and components. Please respect in case of discarding that 

electrical devices should be disposed of separately from household waste at the end of their service life. Therefore, please take this 

device to a municipal collection point that return used electronic devices to the recycling system. Disposing it correctly will support 

environmental protection and will prevent any potential negative effects on human beings and the environment that could arise 

from inappropriate handling of these devices at the end of their service life. Please contact your local authority for further details of 

your nearest designated collection point or recycling site. 
Business customers: If you wish to discard equipment, please contact your dealer or supplier for further information.

3. Environment and Recycling

• 

All information in this manual is for reference only. If there are any errors or omissions, the specifications produced by the factory shall prevail. 

Specification is subject to change without prior notice.

• 

If there is any inconsistency or ambiguity between the English version and the Chinese version of this manual, the English version shall prevail.

• 

Refer to www.germanpool.com for the most up-to-date version of the Operating Instructions.

Summary of Contents for GERMAN POOL DSN

Page 1: ...structions and warranty information carefully before use and keep them handy for future reference Online Warranty Registration U S E R M A N U A L DSN Instantaneous Electric Water Heater WH DSN M 20 1...

Page 2: ...ed to frost The values stated on the rating plate must be observed In case of malfunction disconnect the fuses immediately In case of leaks cut off the mains water supply instantly Repairs must only b...

Page 3: ...he devices must not be blocked and the water flow must not be restricted The water outlet facilities such as shower head jet control and other outlet unit must be decalcified regularly Deposits must b...

Page 4: ...load shedding relay for electronically controlled instantaneous water heaters refer to installing instructions This device complies with Directive 2014 53 EU Operation Instructions Note Carefully rea...

Page 5: ...e recorded by the appliance In order to use the Automatic function correctly according to the fill quantity it is there fore necessary to set the desired temperature on the appliance and only turn on...

Page 6: ...play and an alarm signal can be heard until the prompt is acknowledged by tapping on OK Operation Lock Secure your settings with a four digit PIN Note The operation lock can only be deactivated with t...

Page 7: ...es not suffice to heat the tapped quantity of water the control valve automatically reduces the flow rate so that the set temperature is reached How to Save Energy Set the exact temperature you need o...

Page 8: ...d by a firewall Protect the appliance against unauthorised access by using a secure Wi Fi pass word This should consist of letters numbers and special characters and should not be listed in the lexico...

Page 9: ...l restarts and check the function of the DSN If an update is not possible even after multiple attempts contact the after sales ser vice Use All functions described in chapter 3 How to use can also be...

Page 10: ...ased on Germany standard ie 400V 18kW 3 400 26A Actual wiring size based on EMSD Code Of Practice For Electricity wiring Regulation s Appendix A6 1 1 Maximum applicable cable size is 10mm2 in electric...

Page 11: ...diate proximity of metal surfaces to allow a reliable wireless connection and an optimal wireless range Dimensions in mm Based on Germany s guidelines a general test certificate concerning the evidenc...

Page 12: ...union nut and the inch seal onto the cold water connection 2 Screw the hot water connection piece with the union nut and the inch seal onto the hot water connection 5 Installation Installing the Appl...

Page 13: ...Then select the point Load shedding If the menu item is grayed out first activate the Expert Mode under Settings Software You can set a value of 0 1 or 2 bay tapping or The locking function must be ac...

Page 14: ...m Above S WARNING WARNING Before making the electrical connection fill the mains and the appliance with water by carefully opening and closing the hot water tap in order to vent completely To ensure a...

Page 15: ...the screw behind this cover and detach the hood 3 Close the shut off valve a in the cold water connection piece position closed 4 Unscrew the screw plug b from the cold water connection piece and take...

Page 16: ...33 34 34 37 37 37 37 37 37 38 38 3 Smart Control 39 39 39 40 Wi Fi 40 40 40 4 41 1 42 2 43 3 43 4 44 5 44 44 45 46 46 47 6 48 7 49 49 49 49 50 50 8 51 51 51 52 52 9 53 53 1 DSN 20 C 60 C DSN 70 C Dir...

Page 17: ...32 33 C 20 C 60 C 1 C 35 C 43 C 0 5 C 20 C 8 35 C 38 C 42 C 48 C 3 PIN Wi Fi CLAGE 2 MAIN MENU AUTOMATIC Duration 3 00 00 10 Fill Up 3 1 01 2...

Page 18: ...uage Currency HK C Temperature Limit 0 1 2 2 Operation Lock PIN PIN PIN PIN PIN 0 9 4 OK PIN OK PIN Protected Sections PIN PIN PIN PIN PIN PIN Brightness 5 100 0 100 0 1 5 Sound Load Shedding Expert M...

Page 19: ...low Limit 8 4 5 25 9 0 8 Factory Settings Synchronize Statistics Devices Wi Fi DSN 4 CLAGE Smart Control Software Info 2 USER 8 SAVINGS HK P 34 HK kWh HK m 35 C 38 C 42 C 48 C 8 INFO DEVICE INFORMATIO...

Page 20: ...Store Google Play Store CLAGE Smart Control 3 DSN Wi Fi Device DSN Advanced Client Accesspoint 1 Network SSID SSID 2 Wi Fi Apply 3 DSN Wi Fi 4 Smart Control DSN 5 Smart Control Device DSN Connect DSN...

Page 21: ...8215 info germanpool com 3 Smart Control SOFTWARE UPDATE Smart Control DSN iOS Apple App Store Update Smart Control Android OS Google Play Store Smart Control DSN DSN DSN Wi Fi 1 2 DSN 3 4 3 5 DSN Use...

Page 22: ...C 3 PE 400V AC 1 4 0mm2 4 0mm2 6 0mm2 6 0mm2 2 t 28 K t 38 K 9 2 6 8 10 7 7 9 12 3 9 0 13 8 10 2 0 4l 1 0MPa 10bar IES 15 1100 cm 90mS m 70 C 1 5l min automatic 3 0 08bar at 1 5l min 1 3bar at 9 0l mi...

Page 23: ...00 170 468 363 56 96 239 Dimensions in mm 5 16952 mm e g VDE 0100 EN 806 VDE 0100 part 701 IEC 60364 7 IP25 1 DIN 16893 Series 2 15 1 100 cm RDX3 36100 RDX IP25 IP24 VDX 34120 RDX UDX 34110 RDX 5 RDX3...

Page 24: ...46 47 2 1 12 12 14 2 6 3 4 30 1 1 2 2 1 2 5 a closed open 1 3 1 2 3 3 8 3 8 4 a 5 5 600x600...

Page 25: ...48 49 6 1 2 1 2 1 2 1 2 D 3 8 3 8 6 1 2 1 2 1 2 7 1 2 5 3 4 e g VDE 0100 IEC 3 C L2 x 0 1 2 x x 7 0 1 2 1 35 C 2 1 2 3 4 5...

Page 26: ...50 51 A 7 S 1 6 2 3 4 A 5 1 S 2 3 4 5 6 7 8 9 IP25 8 SDB STB MPS 27kW 400V 24kW 21kW 18kW 1 Approved DIN VDE0100 1 2 3 18 21 24 27kW 4 OK 5 6 10 30 7 8 9 EN60900...

Page 27: ...52 53 8 Pos OFF Pos 1 55 C 55 C 55 C 1 2 3 1 4 1 2 OFF 3 9 a closed open c b Strainer 1 2 3 a 4 b c 5 6 7 8 9 1 2 3 4 5 6 7 8 9...

Page 28: ...l purchaser 1 2 3 4 5 www germanpool com Specifications are subject to change without prior notice If there is any inconsistency or ambiguity between the English version and the Chinese version the En...

Page 29: ...Guangdong 3 F Edificio Industrial Pou Fung 145 Rua de Francisco Xavier Pereira Macau Tel Fax 853 2875 2699 853 2875 2661 Macau All rights reserved Copying reproducing or using the contents of this ma...

Reviews: