WS1”, 1.5” & 2” Series Watersoftener
Installation Operation Maintenance Manual
SIMPWS1 REV3 13/07/11 PAGE 20 OF27
11.1.4
WS2 150-750 L
PARAMETER
UNITS
150L
200L
250L
300L
350L
500L
750L
MAX.SERVICE
FLOW
M3/hr
6
8
10
12
14
20
24
SYSTEM
CAPACITY
Kg
CaCO3
7.5
10
12.5
15
17.5
25
37.5
CAPACITY @
300PPM
M3
25
33.4
41.75
50.1
58.45
83.5
125.2
5
SALT USED
PER REGEN
Kg
21
28
35
42
49
70
105
REGENERATIO
N TIME
MIN
96
120
120
140
140
140
140
SALT STORAGE
CAPACITY
Kg
300
400
500
500
750
750
1000
MAX
OPERATING
TEMP
O
C
50
50
50
50
50
50
50
MAX FLOW TO
DRAIN
LIT/MIN
26.5
37.85
37.85
56.78
56.78
94.63
132.4
8
IMPORTANT NOTES
Much of the data quoted in the above table is affected by the inlet pressure,
and so should be regarded as nominal only.
Total flow to drain will be similarly affected and is therefore not quoted, but