8.0 ROUTINE MONITORING
The following recommendations are made to help the user of the
softener confirm that it is performing as required, and to give early
warning of possible problems. The operation of the softener is
completely automatic, and should not require adjustment.
Weekly
Check the treated water hardness with a hardness test kit.
Inspect the level of salt in the salt tank and refill if necessary.
Monthly
Check raw water hardness, and record. Compare with original
hardness and adjust volume capacity setting if required (see Section
12.0).
Annually
Inspect and clean/replace as necessary the brine injector, brine screen
and the inernal disc/flapper set. This should be performed by a
competent engineer familiar with the WS1 valve.