WS1”, 1.5” & 2” Series Watersoftener
Installation Operation Maintenance Manual
SIMPWS1 REV3 13/07/11 PAGE 19 OF27
11.1.3
WS1.5 100-500 L
PARAMETER
UNITS
100L
120L
150L
250L
350L
500L
MAX.SERVICE
FLOW
M3/hr
4
4.8
6
10
11.6
11.6
SYSTEM CAPACITY
Kg
CaCO3
5
6
7.5
12.5
17.5
25
CAPACITY @
300PPM
M3
16.7
20
25
41.75
58.45
83.5
SALT USED PER
REGEN
Kg
14
16.8
21
35
49
70
REGENERATION
TIME
MIN
96
96
96
120
140
140
SALT STORAGE
CAPACITY
Kg
160
160
300
400
500
750
MAX OPERATING
TEMP
O
C
50
50
50
50
50
50
MAX FLOW TO
DRAIN
LIT/MIN
19
19
26
37
56
94
IMPORTANT NOTES
Much of the data quoted in the above table is affected by the inlet pressure,
and so should be regarded as nominal only.
Total flow to drain will be similarly affected and is therefore not quoted, but
will be about 6 times the resin volume.