background image

TIMER 1-A

TIMER 1-B

TIMER 1-A2

TIMER 1-B2

“1” is displayed if 
set for more than 
one sequence

Page 16 

 

WS2H Control Valve Manual

Timer Screens

continued on Page 17

 Returns to normal operation after 5 minutes.

A NEXT & DN reset from 
this screen unlocks the 
setup screens.

Accessed by pressing NEXT and DOWN simultaneously 

for >3 seconds, then by pressing NEXT and DOWN 

simultaneously again for >3 seconds.

TIMER 1-A
Select time of cycle 1.

TIMER 1-B
Select time of cycle 2.  

The following screens only show if the unit is 
programmed for multiple regenerations in the 
Cycle Setup 2 screen.

TIMER 1-A2
Select time of alternate regen, cycle 1.

TIMER 1-B2
Select time of alternate regen, cycle 2.

Cycle

Units

Range

Increments

Backwash

Minutes

1-30

30-95

1
5

Draw

Minutes

1-30

30-100

100-180

1
5

10

Slow Rinse

Minutes

1-30

30-95

1
5

Rinse

Minutes

1-30

30-95

1
5

Fill

Minutes

0.1-10.0

10.0-30.0
30.0-99.0

0.1
0.2
1.0

Hold

Minutes

1-30

30-100

100-480

0.1
2.0

10.0

Summary of Contents for Water Specialist 2H

Page 1: ...Water Specialist 2H Control Valve Manual...

Page 2: ...d four Molex pins P N 08 50 0108 b Pin 1 24 0 VAC White Pin 2 Jumper to Pin 3 Pin 3 Jumper to Pin 2 Pin 4 24 0 VAC Black Custom Meter Wiring 1 Terminate end with a Molex series 2695 housing part numbe...

Page 3: ...he rod indicates that the unit is in service Viewing the rod as shown on the MAV indicates that the common port is currently connected to the B port If the rod is not visible the unit is offline in th...

Page 4: ...or Non Functional Input On Slaves Must Use Master Slave Port Separate Source Inlet Motor Drive Motor Driven Bypass Manual Over Ride Place in center for normal operation Up forces online down forces of...

Page 5: ...All Wiring Connections Apply To All Units Cables Communication Bypass Up forces online down forces offline Place in center for normal operation Display Pod Unit 3 24 VAC Meter Unit 2 Unit 4 Transform...

Page 6: ...2 24 VAC Transformer Power Switch Input Auxilliray DP Cables Communication Dry Contacts Relay 1 Output Dry Contacts Display Pod Relay 2 Output Bypass Meter Motor Driven Motor Main Drive Functional No...

Page 7: ...WS2H Control Valve Manual Page 7...

Page 8: ...Page 8 WS2H Control Valve Manual...

Page 9: ...WS2H Control Valve Manual Page 9...

Page 10: ...Page 10 WS2H Control Valve Manual...

Page 11: ...splay if days override is set to OFF Days remaining can be decremented one day at a time by holding the DOWN arrow 3 seconds USER 3 Displays time of day USER 4 Displays the unit s current flow rate US...

Page 12: ...n to Normal Operation UNIT COUNT ERROR Error and the slave s unit number will flash when it is not detected Pressing any button will return the user to the units set up screen to correct the value ERR...

Page 13: ...ll hours AM PM alternates at midnight on0 will be displayed on units with no time dependent regen control INSTALLER 4 Select time of regen Use up and down arrows to scroll minutes INSTALLER 5 Select t...

Page 14: ...keeping one unit off line at all times The screen will not display if set to 1 unit SYSTEM SETUP 4 Single units have a selection of hard water bypass no hard water bypass or relay operation When the u...

Page 15: ...regen START TIME REGEN regeneration will start immediately after 2 cumulative minutes of switch closure START TIME REGEN dEL regeneration will start at the delayed time after 2 cumulative minutes of...

Page 16: ...usly again for 3 seconds TIMER 1 A Select time of cycle 1 TIMER 1 B Select time of cycle 2 The following screens only show if the unit is programmed for multiple regenerations in the Cycle Setup 2 scr...

Page 17: ...unit regeneration or when it would be offline in system operation REGEN Relay closes when the unit is in regen Err Relay closes when the unit is in any error mode TIMER 4 Select output 1 On trigger se...

Page 18: ...Returns to normal operation after 5 minutes Accessed by pressing NEXT and DOWN simultaneously for 3 seconds then by pressing NEXT and DOWN simultaneously again for 3 seconds then by pressing NEXT and...

Page 19: ...ion cycle sequence 1 a selected number of times before regenerating a single time with sequence 2 The following screens only show if the unit is programmed for multiple regenerations in the previous s...

Page 20: ...last regeneration DIAGNOSTICS 2 Gallons or Liters x1000 since the last regeneration DIAGNOSTICS 3 Reserve history This screen only appears if valve is set to calculate Reserve in System Setup 7 Use ar...

Page 21: ...DIAGNOSTICS 6 Total volume through the unit DIAGNOSTICS 7 System totalizer for the last 63 days Only displays in a master unit System use for that day DIAGNOSTICS 7 B Hourly system totalizer Use the U...

Page 22: ...ed by pressing UP and DOWN simultaneously for 3 seconds then by pressing UP and DOWN simultaneously again for 3 seconds HISTORY 1 Total days since startup Time only accumulates while the unit is plugg...

Page 23: ...WS2H Control Valve Manual Page 23 Hard Water To Drain Backwash Supply Raw Water Inlet Raw Water Inlet Service Treated Water Supply...

Page 24: ...Page 24 WS2H Control Valve Manual Draw Inlet Drawn In Solution Is Supply Hard Water Raw Water To Drain Hard Water To Drain Slow Rinse Supply Raw Water Inlet...

Page 25: ...WS2H Control Valve Manual Page 25 Softwater Fill Supply Treated Water Raw Water Inlet Treated Water To Tank Hard Water Supply To Drain Rinse Raw Water Inlet...

Page 26: ...S2 DRIVE BRACKET ASY 1 8 V3110 WS1 DRIVE GEAR 12X36 3 9 V3109 WS1 DRIVE GEAR COVER 1 Not Shown V3461 WS2 AC ADAPTER 24V 1 Not Shown V3461EU WS2 AC ADAPTER 24V EU Not Shown V3461UK WS2 AC ADAPTER 24V U...

Page 27: ...SPT THREADS 17 V3054 WS2 4 IN BASE CLAMP ASY 1 18 V3276 WS2 BOLT HEX SS 5 16 18X1 3 4 1 19 V3269 WS2 NUT 5 16 18 SS HEX 1 Not Shown D1300 01 TOP BAFFLE DFSR CLACK 2 63MM 1 V3054 WS2 4 IN BASE CLAMP AS...

Page 28: ...ING 1 14 V3151 WS1 NUT 1 QC 1 15 V3149 WS1 FTG 1 PVC MALE NPT ELBOW 1 Not Shown V3189 WS1 FTG 3 4 1 PVC SLVNT 90 Optional 16 V3010 2A WS2 INJECTOR ASY A 1 V3010 2B WS2 INJECTOR ASY B V3010 2C WS2 INJE...

Page 29: ...ontrol Valve Manual Page 29 Drawing No Order No Description Quantity 1 V3202 01 WS2 BASE 1 2 V3281 O RING 348 1 Drawing No Order No Description Quantity 1 V3444 WS2 SCREW HEXCAP 5 16 18X2 5SS 12 2 V32...

Page 30: ...7 5 gpm for 3 4 V3162 090 WS1 DLFC 9 0 gpm for 3 4 V3162 100 WS1 DLFC 10 0 gpm for 3 4 V3190 090 WS1 DLFC 9 0 gpm for 1 V3190 100 WS1 DLFC 10 0 gpm for 1 V3190 110 WS1 DLFC 11 0 gpm for 1 V3190 130 WS...

Page 31: ...SY NPT 1 1 V3057BSPT WS2 BYPASS BODY ASY BSPT Not Shown V3053 WS2 2 1 2 GROOVELOCK CLAMP ASY 2 2 V3060 WS2 BYPASS AUTO NPT V3060BSPT WS2 BYPASS AUTO BSPT V3061BSPT WS2 BYPASS MANUAL BSPT and V3061 WS2...

Page 32: ...Drawing No Order No Description Quantity 1 V3053 WS2 2 1 2 GROOVELOCK CLAMP ASY 1 2 V3290 WS2 GROOVE LOCK SEAL 2 5 1 3 V3269 WS2 NUT 5 16 18 SS HEX 1 4 V3293 WS2 WASHER SS 5 16 FLAT 1 5 V3276 WS2 BOLT...

Page 33: ...ulty drive component creating drag Missing engagement between separate source drive motor and main gear Separate source drive motor not connected to system board Faulty separate source drive motor or...

Page 34: ...14 16 18 20 40 60 80 100 120 Pressure psi Flow Rate gpm Order No V3010 2A US Units Total Slow Rinse Draw 0 1 2 3 4 20 40 60 80 100 120 Pressure psi Flow Rate gpm Order No V3010 2C US Units Total Slow...

Page 35: ...0 600 700 800 900 Pressure kPa Flow Rate lpm Order No V3010 2E Metric Units Total Slow Rinse Draw 0 10 20 30 40 50 60 100 200 300 400 500 600 700 800 900 Pressure kPa Flow Rate lpm Order No V3010 2A M...

Page 36: ...UNT BASE BSPT ASY Added drawing and table PAGE 31 6 V3264 WS2 BYPASS REDUCTION GEAR AXLE 3 N A 06 25 07 PAGE 29 V3260 02 WS2 SIDE MOUNT BASE NPT 09 06 07 PAGE 27 Update Tubine Asy part V3118 03 and Tu...

Reviews: