SYSTEM SETUP 6
SYSTEM SETUP 7
SYSTEM SETUP 8
SYSTEM SETUP 9
SYSTEM SETUP 9B
SYSTEM SETUP 10
WS2H Control Valve Manual
Page 15
System Setup Screens (continued)
SYSTEM SETUP 6
Select regeneration type.
Delayed (dEL-1)
Delayed, 2 regenerations per day (dEL-2)
Delayed, 3 regenerations per day (dEL-3)
Delayed, 4 regenerations per day (dEL-4)
On 0
Delayed with multiple regenerations allowed per day would be
used either to reduce the reserve volume, or to accommodate a
small system relative to the treatment demand.
SYSTEM SETUP 7
Select reserve calculation ON or OFF.
OFF will schedule a regen when the volumetric
capacity reaches 0. This screen will not display
for “on0” units or systems.
SYSTEM SETUP 8
Set auxiliary initiated regen.
START TIME REGEN: regeneration will start immediately after 2 cumulative
minutes of switch closure.
START TIME REGEN dEL: regeneration will start at the delayed time after 2
cumulative minutes of switch closure.
START REGEN: regeneration will start immediately upon switch closure.
START REGEN dEL: regeneration will start at the delayed time upon switch closure.
HOLD REGEN: regeneration will not be allowed as long as there is switch closure.
SYSTEM SETUP 9
Select meter type or pulses.
2.0 meter (type)
1.5 meter (type)
System Pulses
SYSTEM SETUP 9B
Select meter type pulses.
Screen does not show if Pulses or System Pulses is not
selected in the previous screen.
Pulses/ Unit Flow
Units
Range
Increments
US
(Pulse/Gal)
0.1 - 30.0
30.0 - 999.0
0.1
1.0
SI (Pulse/L)
0.4 - 114.0
114.0 - 519.4
0.4
3.8
SYSTEM SETUP 10
Separate source inlet. This screen will not
display if a system board is not installed.
Return To
Normal Operation