FUNCTION
FACTORY VALUE
TYPE OF VALUE
Battery Discharging Current (mA) Battery discharging current
Depend on the power consumption
on the output voltage 12 V and
24 V (0 mA if the turbine is
charging the battery)
Automatic
Input Power > Output Power (W)
Live power consumption of
the battery
If green: Battery charging
(power)
If red: Battery discharging
(current )
Automatic
Start turbine @ Low Battery
Level (V)
Low level battery
Used to restart the turbine
12.0 V
Default value
Start Temporisation @ High
Battery level (V)
High battery level is used to
start the temporization. At
the end of the
temporization, the turbine
shuts off automatically
13.0 V
Default value
Alarm Battery Level (V)
Alarm battery level dry
contact (terminal 3
connections 5 and 6) = 1 if
alarm battery level
11.0 V
Default value
Solenoid Pulse
Milliseconds (ms)
Pulse duration to switch the
solenoid
99 ms
Default value
Forced charge 1 Hour (h)
Forced charge (available if
the system is not charging)
05:00 h
Default value
Forced charge 2 Hour (h)
Forced charge (available if
the system is not charging)
17:00 h
Default value
See column « De