![CKD Rapiflow FSM2 Series Instruction Manual Download Page 17](http://html1.mh-extra.com/html/ckd/rapiflow-fsm2-series/rapiflow-fsm2-series_instruction-manual_2611675017.webp)
[SM-385853-A]
−
16
−
INSTALLATION
1
1.3.2
FSM2-P series
(
Integrated indicator type, PNP output type
)
connector
M
a
in
c
irc
ui
t
Load
Load
Load
(
Brown
)
Power supply
+
(
Gray
)
Analog output
(Blue) Power supply -
+
−
(
Black
)
CH1
SW output
1
(
White
)
CH2
SW output 2
2
3
4
5
1
M
a
in
c
irc
ui
t
Load
Load
(
Brown
)
Power supply
+
(
Gray
)
Analog output
(Blue)Power supply -
+
−
(
Black
)
CH1
SW output
1
(
White
)
CH2
Input
2
3
4
5
1
CH2 function selected
switch output
CH2 function selected
external input
※
Analog voltage output R : approx.1k
Analog current output R : approx.100
Pin
No.
Line color
Content
[1]
Brown
Po
wer supply (+) (voltage output: 12 to 24 V, current output: 24 V)
[2]
Black
CH1(Switch output 1: max50mA)
[3]
White
CH2(Switch output 2: max50mA or External input)
[4]
Gray
Analog output Voltage output: 1 to 5 V load impedance 50 k and over
Current output: 4 to 20 mA load impedance 300 or less
[5]
Blue
Power supply- (GND)
[1] [2] [3] [4] [5]
(FSM2 side)
Discontinue