[SM-P00049-A]
-
8
-
PRODUCT
1
The transmission distance described above indicates the distance in
configuring the entire system with Ver. 1.10 compatible unit and cable.
Where Ver. 1.00 compatible unit is connected to even one unit (com-
patible with Ver. 1.10), and Ver. 1.00 compatible cable is used for wiring,
the system is of Ver. 1.00 type.
For details, refer to the Master Station User
’
s Manual.
Since the wiring distance, etc. differs where the system is used with
Ver. 1.00, refer to the Master Station User
’
s Manual.
In Ver. 1.10, mixed use of cable manufacturers is allowable. In Ver.
1.00, however, no mixed use of cable manufacturers is allowed.
There are various limits to T-branch connection, such as usable cables
and the number of units to be connected.
Be sure to refer to the Master Station User
’
s Manual and check the
contents before wiring.
Since the transmission distance changes, depending on the transmission
speed and communication cable to be used or the like, see
“
CC-Link
”
User
’
s Manual released by MITSUBISHI ELECTRIC or contact the cable
maker for its checking.
Since the number of stations (remote stations) differs, depending on
various conditions, such as the number of occupied stations and trans-
mission distance, refer to
“
CC-Link
”
User
’
s Manual released by MIT-
SUBISHI ELECTRIC or contact the cable maker for checking.
No mixed use of cables only for CC-Link and high-performance cables
only for CC-Link is allowed.
3) Slave station specification
Item
Specification
Communication object
CC-Link
Ver1.10 (Note 1)
Power supply voltage(Unit side)
DC21.6V to 26.4V (DC24V
±
10%)
Consumption current(Unit side)
100mA or lower (While 16 output are ON.)
Power supply voltage(Valve side)
DC22.8V to 26.4V (DC24V
±
10%, -5%)
Consumption current(Valve side)
15mA or lower (While all points are OFF.)
Insulation resistance
Between all external terminals in a lump and Case
20M
Ω
or more
DC500VM
Withstand voltage
Between all external terminals in a lump and Case
AC500V
for 1 minute
Noise resistance
500Vp-p
Pulse width 100nsce, 1
μ
sec
Durability
10Hz to 150Hz to 10Hz
1 octave / min.
15 sweeps in the 3 each axis of X, Y and Z
while the half amplitude is 0.75mm or 10G whichever smaller.
Mechanical
vibration proof
Wrong operation
10Hz to 150Hz to 10Hz
1 octave / min.
4 sweeps in the 3 each axis of X, Y and Z
while the half amplitude is 0.5mm or 7G whichever smaller.
Mechanical shock proof
30G
3 directions
3 times
Ambient temperature
0 to 55
℃
Ambient humidity
30 to 85%RH (No dew fall)
Working environment
No corrosive gas
No. of output points
16 points
Output insulation type
Photo coupler insulation
Max. load current
100mA/1 point
Leak current
0.1mA or lower
Residual voltage
0.5V or lower
Output model
NPN Transistor, Open collector output
Operating indication
LED (power lamp and communication status indicator only)
No. of monopolized stations
1 station
!
CAUTION
CAUTION
CAUTION
CAUTION
:
::
: