[SM-P00049-A]
―
25
―
OPERATION
3
3.2 Correspondence between Output Nos. and internal connector Nos.
Those Numbers correspond as per table, posted below.
Triangle
▽
⑪
⑫
⑬
⑭
⑮
⑯
⑰
⑱
⑲
⑳
Correspondence
between Output Nos.
0 1 2 3 4 5 6 7 8 9 A B C D E F
①
②
③
④
⑤
⑥
⑦
⑧
⑨
⑩
Internal
connector pin No.
1 2 3 4 5 6 7 8 11 12 13 14 15 16 17 18
Connector
Internal connector pin No.
3.3 Correspondence between Output Nos. and Valve solenoid Nos.
(1) Connector pin Nos. and manifold solenoid correspond with each other as per tables posted
below.
(2) Manifold block number is allocated from leftmost block toward right while holding piping
port facing to you, regardless the location of wiring block.
Manifold wiring example
For single solenoid valve
Connector pin No.
0(1)
1(2)
2(3)
3(4)
4(5)
5(6)
6(7)
7(8) 8(11) 9(12) A(13) B(14) C(15) D(16) E(17) F(18)
1st station
○
2nd station
○
3rd station
○
4th station
○
5th station
○
6th station
○
7th station
○
8th station
○
Symbol
○
Solenoid (a) side
(Correspond with up the 8th solenoid valve.)
Manifold station number
1st station
2nd station
3rd station
nth station