[SM-P00049-A]
―
23
―
OPERATION
3
1) Station number setting (SW1 and SW2)
Assign a station number to the slave station using a number between 01 and 64.
Use the “
10” switch to specify the 10 col-
umn digit in the station number.
Use the “
1” switch to specify the 1 column
digit in the station number.
(Can
’
t use the same station No.)
2) Transfer rate setting (SW3)
Set the transfer rate for communication between the master and slave stations.
Position
Transfer rate
0
156kbps
1
625kbps
2
2.5Mbps
3
5Mbps
4
10Mbps
Be sure to set the switch to a position between 0 to 4.
Set the transmission speed to the same level as with all master sta-
tions, local stations and remote stations on the network. If the set-
ting differs in even one station, no normal data link can be achieved.
!
CAUTION
CAUTION
CAUTION