Page 13
The size of the gas service pipe is dependant upon many variables,
such as tees, lengths, etc. Specific pipe size should be obtained from
the gas supplier. Refer to the
Gas Pipe Size
Chart
in this manual for
general
gas pipe size
information.
CAUTION
Gas loop piping must be installed as shown in Illustration, to
maintain equal gas pressure for all dryers connected to a single
gas service.
Other gas using appliances should be connected upstream
from the loop.
WARNING
(LIQUIFIED PETROLEUM GASES ONLY)
A Gas Pressure Regulator for Liquified Petroleum Gases is
not furnished on Gas Heated Clothes Dryers. This regulator
is normally furnished by the installer. In accordance with
American Gas Association (AGA) standards, a gas pressure
regulator, when installed indoors, must be equipped with a
vent limiter, or a vent line must be installed from the gas
pressure regulator vent to the outdoors.
Gas Piping
GAS SERVICE
INSTALLATION
INFORMATION
Summary of Contents for HD125
Page 9: ...Page 9 125 lb General Dimensions Illustration...
Page 10: ...Page 10 125 lb Steam Heated Dryer Dimensions Illustration...
Page 14: ...Page 14 Gas Loop Piping and Gas Supply Piping System Illustrations...
Page 18: ...Page 18 Steam Piping Installation Illustration...
Page 20: ...Page 20 Dryer Installation with Multiple Exhaust Illustration...
Page 27: ...Page 27 Two Timer Models Figures 1 2 and 3 Illustrations...
Page 35: ...Page 35 DIRECTSPARK IGNITIONOPERATION FLOW CHART...
Page 37: ...Page 37 Burner Air Inlet Adjustment with Illustration BURNERAIRINLET ADJUSTMENT...
Page 38: ...Page 38 Basket Alignment for 125 lb Dryers Illustrations...
Page 66: ...Page 66...