Unpacking/General Installation (All Dryers)
UNPACKING
GENERAL
INSTALLATION (ALL
DRYERS)
This dryer is packed in a large wooden crate.
Upon arrival of the equipment, any damage in shipment should be reported to
the carrier immediately.
Upon locating permanent location of a unit, care should be taken in movement
and placement of equipment.
See outline clearance diagrams for correct dimensions.
Remove all packing material such as: tape, manuals,
skid, etc.
Leveling: Use spirit level on top of dryer. The use of shims are acceptable for
this procedure.
Check voltage and amperes on rating plate before installing the dryer.
On gear reducer models, remove screw and insert red vent attached to reducer.
The construction of the dryers permits installation side-by-side to save space
or to provide a wall arrangement. Position dryer for the least amount of exhaust
piping and elbows, and allow free access to the rear of dryer for future
servicing of belts, pulleys and motors. Installation clearance from all
combustable material is 12 (305 mm) ceiling clearance, 24 (610 mm) rear
clearance, and 0 side clearance.
Before operating dryer, open basket door and remove blocking between front
panel and basket. Read the instruction tags, owner's manual, warnings, etc.
IMPORTANT
Opening the clothes loading door deactivates the door switch to shut off
the motors, fan, gas, steam, or electric element. To restart the dryer,
close the door and press in the push to start button for approximately 2
seconds.
IMPORTANT
This dryer is designed for a capacity maximum load. Overloading it will
result in long drying times and damp spots on some clothes.
IMPORTANT
Maximum operating efficiency is dependent upon proper air curculation.
The lint screen must be kept clean daily to insure proper air circulation
throughout the dryer.
IMPORTANT
Provide adequate clearance for air opening into the combustion chamber.
Summary of Contents for HD125
Page 9: ...Page 9 125 lb General Dimensions Illustration...
Page 10: ...Page 10 125 lb Steam Heated Dryer Dimensions Illustration...
Page 14: ...Page 14 Gas Loop Piping and Gas Supply Piping System Illustrations...
Page 18: ...Page 18 Steam Piping Installation Illustration...
Page 20: ...Page 20 Dryer Installation with Multiple Exhaust Illustration...
Page 27: ...Page 27 Two Timer Models Figures 1 2 and 3 Illustrations...
Page 35: ...Page 35 DIRECTSPARK IGNITIONOPERATION FLOW CHART...
Page 37: ...Page 37 Burner Air Inlet Adjustment with Illustration BURNERAIRINLET ADJUSTMENT...
Page 38: ...Page 38 Basket Alignment for 125 lb Dryers Illustrations...
Page 66: ...Page 66...