Page 42
Instructions
In operation, coasting of basket increases, making it necessary to
readjust reversing timer.
CAUTION
Failure to do this will cause the thermal overload units for the
basket to cut-out unnecessarily and probably damage the
gear reducer.
Adjustment of Reversing Timer Dwell Time
CAUTION
Dryer power supply must be shut off before adjusting timer.
The dwell time is the time from when the motor turns off, to when
it turns on again in the opposite direction.
Turning the dwell adjustment knob counter-clockwise increases the
dwell time and turning it clockwise decreases the dwell time.
Recommended dwell time for the basket to stop completely is 5 to 7
seconds. Minimum basket stopping time is
4 seconds.
NOTE
Select non-reversing or reversing before starting dryer.
NOTE
Fan rotates counter-clockwise as viewed from back end of
motor. See arrow on motor support. to change rotation,
reverse power leads L1 and L2.
Dryers with Reversing Control Timer
INSTRUCTIONS FOR
DRYERS WITH
REVERSING CONTROL
TIMER
Summary of Contents for HD125
Page 9: ...Page 9 125 lb General Dimensions Illustration...
Page 10: ...Page 10 125 lb Steam Heated Dryer Dimensions Illustration...
Page 14: ...Page 14 Gas Loop Piping and Gas Supply Piping System Illustrations...
Page 18: ...Page 18 Steam Piping Installation Illustration...
Page 20: ...Page 20 Dryer Installation with Multiple Exhaust Illustration...
Page 27: ...Page 27 Two Timer Models Figures 1 2 and 3 Illustrations...
Page 35: ...Page 35 DIRECTSPARK IGNITIONOPERATION FLOW CHART...
Page 37: ...Page 37 Burner Air Inlet Adjustment with Illustration BURNERAIRINLET ADJUSTMENT...
Page 38: ...Page 38 Basket Alignment for 125 lb Dryers Illustrations...
Page 66: ...Page 66...