1. The installation must conform to
local codes
or in absence of
local codes, with the
National Fuel Gas Code, ANSI Z223 or
the CAN/CGA-B149, Installation Codes.
2. Check with utilities for proper gas pressure and gas supply
line.
3. Check for altitude elevation of the dryer.
4. The dryer and its individual shut-off valve must be
disconnected from the gas supply piping system at test
pressures in excess of 1/2 PSIG (.04 bar).
5. The dryer must be isolated from the gas supply piping system
by closing its individual manual shut-off valve during any
pressure testing of the gas supply piping system, at test
pressures equal to or less than 1/2 PSIG (.04 bar).
NATURAL GAS ONLY
Check the gas pressure inlet supply to the dryer, 11WC
(27.4 bar)Pressure maximum. Check the manifold pressure,
3.5WC (8.8 bar) Pressure inside the dryer.
CAUTION
Low gas pressure and intermittent gas will cause gas ignition
problems and inadequate drying of the clothes load.
Gas Piping Installation
GAS PIPING
INSTALLATION
Summary of Contents for HD125
Page 9: ...Page 9 125 lb General Dimensions Illustration...
Page 10: ...Page 10 125 lb Steam Heated Dryer Dimensions Illustration...
Page 14: ...Page 14 Gas Loop Piping and Gas Supply Piping System Illustrations...
Page 18: ...Page 18 Steam Piping Installation Illustration...
Page 20: ...Page 20 Dryer Installation with Multiple Exhaust Illustration...
Page 27: ...Page 27 Two Timer Models Figures 1 2 and 3 Illustrations...
Page 35: ...Page 35 DIRECTSPARK IGNITIONOPERATION FLOW CHART...
Page 37: ...Page 37 Burner Air Inlet Adjustment with Illustration BURNERAIRINLET ADJUSTMENT...
Page 38: ...Page 38 Basket Alignment for 125 lb Dryers Illustrations...
Page 66: ...Page 66...