• System messages are displayed.
• Call Home alerts are sent (if configured). For more information, refer
Associating an Alert Group with
.
• SNMP notifications are sent (if configured). For more information, refer
.
Each of the three fan trays cover two fabric modules as follows:
• Fan tray in slot 41 covers the fabric modules in slots 21 and 22.
• Fan tray in slot 42 covers the fabric modules in slots 23 and 24.
• Fan tray in slot 43 covers the fabric modules in slots 25 and 26.
If you need to replace a fabric module, you must remove the fan tray covering the fabric module before you
replace the fabric module. You must replace the fabric module and its covering fan tray within three minutes
or an overtemperature condition can occur.
Displaying the Status for the Fan Trays
Enter the
show environment fan
command.
Example:
switch# show environment fan
Fan:
------------------------------------------------------
Fan
Model
Hw
Status
------------------------------------------------------
Fan1(sys_fan1)
N77-C7710-FAN-2
0.100
Ok
Fan2(sys_fan2)
N77-C7710-FAN-2
0.100
Ok
Fan3(sys_fan3)
N77-C7710-FAN-2
0.100
Ok
Fan_in_PS1
--
--
Ok
Fan_in_PS2
--
--
Ok
Fan_in_PS3
--
--
Ok
Fan_in_PS4
--
--
Absent
Fan_in_PS5
--
--
Ok
Fan_in_PS6
--
--
Ok
Fan_in_PS7
--
--
Ok
Fan_in_PS8
--
--
Absent
Fan Zone Speed %(Hex): Zone 1: 40.78(0x68)
Cisco Nexus 7710 Switch Site Preparation and Hardware Installation Guide
OL-30452-01.
84
Managing the Switch
Displaying the Status for the Fan Trays