• STATUS LED is green.
• SYSTEM LED is green.
• ACTIVE LED is amber or green.
For more information about the LED states for this module, see
Supervisor Module LEDs, on page 192
i)
Attach the management cable to the MGMT ETH port.
The MGMT ETH LED should be green. If not, see
Supervisor Module LEDs, on page 192
for information about the
LED states.
Migrating from Supervisor 2E Modules (N77-SUP2E) to
Supervisor 3E Modules (N77-SUP3E)
To migrate from Supervisor 2E modules to Supervisor 3E modules, follow these steps:
Before you begin
• Before migrating from Supervisor 2E modules to Supervisor 3E modules, note the following guidelines:
• This migration process is disruptive because the power must be turned off for the switch.
• You cannot mix Supervisor 2E and Supervisor 3E modules in a production environment.
Step 1
Insert a USB drive in the usb1 or the slot0 USB port on the active supervisor 2E module. We will use the usb1 port for
the steps given below.
Step 2
Format the drive by using the
format
command.
switch(config)#
format usb1
Step 3
Copy all of the VDC configurations for the switch to the USB drive by using the
copy running-config
command.
switch(config)#
copy running-config usb1:configuration_file_name vdc-all
Step 4
Backup the installed licenses for the switch to the USB drive by using the
copy licenses
command.
switch(config)#
copy licenses usb1:licenses_archive_file_name.tar
You must use the
tar
extension for the archive file. This file will contain all of the license files that were
installed on the Supervisor 2E module.
Note
Step 5
Copy the Supervisor 3E version of the kickstart, system, and EPLD (optional) images to the USB drive by using the
copy
command.
switch(config)#
copy scp://path/n7700-s3-kickstart.8.3.1.bin usb1:
switch(config)#
copy scp://path/n7700-s3-dk9.8.3.1.bin usb1:
switch(config)#
copy scp://path/n7700-s3-epld.8.3.1.img usb1:
Cisco Nexus 7710 Switch Site Preparation and Hardware Installation Guide
OL-30452-01.
90
Installing or Replacing Modules, Fan Trays, and Power Supplies
Migrating from Supervisor 2E Modules (N77-SUP2E) to Supervisor 3E Modules (N77-SUP3E)