Status
Color
LED
All diagnostics passed. This module is operational (normal
initialization sequence).
Green
Status
Indicates one of the following:
• The module is booting or running diagnostics.
• An overtemperature condition has occurred. (A minor
temperature threshold has been exceeded during environmental
monitoring.)
Amber
Indicates one of the following:
• The switch has just been powered on, and the module is resetting.
• The module has been inserted during the initialization process.
• An overtemperature condition has occurred. A major temperature
threshold has been exceeded during environmental monitoring
• The module has failed to download code and configuration
information successfully during the initial reset. The module is
not online.
Flashing red
Indicates one of the following:
• The module has detected a slot ID parity error and will not power
on or boot up.
• The module is not fully inserted, and it is not making a reliable
connection with the supervisor.
Red
The module is not receiving power.
Off
The port is active (the link is connected and active).
Green
Link (for
each port)
The module or port is disabled by using a CLI command or the
module is initializing.
Amber
The port is faulty and disabled.
Flashing amber
The port is not active or the link is not connected.
Off
Cisco Nexus 7710 Switch Site Preparation and Hardware Installation Guide
195
OL-30452-01.
LEDs
LEDs