Full Redundancy
Mode
Input Source
Redundancy
Mode
Power Supply
Redundancy
Mode
Combined Mode
Power Supplies
Power Inputs
—
—
—
3500 W
1
1 input (220/230
V)
3500 W
3500 W
3500 W
7000 W
2
3500 W
3500 W
7000 W
10,500 W
3
7000 W
7000 W
10,500 W
14,000 W
4
7000 W
7000 W
14,000 W
17,500 W
5
10,500 W
10,500 W
17,500 W
21,000 W
6
10,500 W
10,500 W
21,000 W
24,500 W
7
14,000 W
14,000 W
24,500 W
28,000 W
8
—
—
—
3100 W
1
1 input (210 V)
3100 W
3100 W
3100 W
6200 W
2
3100 W
3100 W
6200 W
9300 W
3
6200 W
6200 W
9300 W
12,400 W
4
6200 W
6200 W
12,400 W
15,500 W
5
9300 W
9300 W
15,500 W
18,600 W
6
9300 W
9300 W
18,600 W
21,700 W
7
12,400 W
12,400 W
21,700 W
24,800 W
8
—
—
—
1500 W
1
1 input (110 V)
1500 W
1500 W
1500 W
3000 W
2
1500 W
1500 W
3000 W
4500 W
3
3000 W
3000 W
4500 W
6000 W
4
3000 W
3000 W
6000 W
7500 W
5
4500 W
4500 W
7500 W
9000 W
6
4500 W
4500 W
9000 W
10500 W
7
6000 W
6000 W
10500 W
12000 W
8
A combination of 3-kW AC and 3.5-kW HVAC/HVDC power supplies can be used.
Note
Cisco Nexus 7710 Switch Site Preparation and Hardware Installation Guide
OL-30452-01.
144
Switch Specifications
Switch Specifications