6-3
Cisco Intrusion Prevention System Appliance and Module Installation Guide for IPS 7.1
OL-24002-01
Chapter 6 Installing the IPS 4345 and IPS 4360
Specifications
Operating power
Steady state/maximum
372W
382W
Total heat dissipation
730 BTU/hr
730 BTU/hr
Output hold-up time
20mS
12mS
Inrush current
40A
40A
Environment
Temperature
Operating: 23°F to 49°F
(-5°C to 45°C)
Nonoperating: -13°F to -94°F
(-25°C to -70°C)
Operating: 23°F to 49°F
(-5°C to 45°C)
Nonoperating: -13°F to -94°F
(25°C to -70°C)
Airflow
Front to back
Front to back
Relative humidity
(noncondensing)
Operating: 0% to 90%
Nonoperating: 10% to 90%
Operating: 0% to 90%
Nonoperating: 10% to 90%
Altitude
Operating: 0 to 10,000 ft
(0 to 3048 m)
Nonoperating: 0 to 15,000 ft
(0 to 4572 m)
Operating: 0 to 10,000 ft
(0 to 3048 m)
Nonoperating: 0 to 15,000 ft
(0 to 4572 m)
Acoustic noise
Operating: 64.2
Nonoperating: 70G,4.22m/s
Operating: 67.9
Nonoperating: 70G,4.22m/s
Shock
50G,2ms
50G,2ms
Vibration
Operating: 0.41Grms,3Hz to 500Hz
with spectral break points of
0.0005G2/Hz at 10Hz and 200Hz
and 5dB/octave roll-off at each end
Nonoperating: 1.12Grms,3Hz to
500Hz with spectral break points of
0.0065G2/Hz at 10Hz and 100Hz
and 5dB/octave roll-off at each end
Operating: 0.41Grms,3Hz to 500Hz
with spectral break points of
0.0005G2/Hz at 10Hz and 200Hz
and 5dB/octave roll-off at each end.
Nonoperating: 1.12Grms,3Hz to
500Hz with spectral break points of
0.0065G2/Hz at 10Hz and 100Hz
and 5dB/octave roll-off at each end
Table 6-1
IPS 4345 and IPS 4360 Specifications (continued)