5-15
Cisco Intrusion Prevention System Appliance and Module Installation Guide for IPS 7.1
OL-24002-01
Chapter 5 Installing the IPS 4270-20
Specifications
For More Information
•
For the location of the Diagnostic Panel in the IPS 4270-20 chassis, see
Figure 5-9 on page 5-13
.
•
For information on how to access the Diagnostic Panel, see
Accessing the Diagnostic Panel,
page 5-42
.
Specifications
Table 5-5
lists the specifications for the IPS 4270-20.
Table 5-5
IPS 4270-20 Specifications
Dimensions and Weight
Height
6.94 in. (17.6 cm)
Width
19.0 in. (46.3 cm)
Depth
26.5 in. (67.3 cm)
Weight
80 lb (36.3 kg)
Form factor
4 RU, standard 19-inch rack-mountable
Power
Rated input voltage
100 to 127 VAC
200 to 240 VAC
Rated input frequency
50 to 60 Hz
Rated input power
1161W @ 100 VAC
1598W @ 200 VAC
Rated input current
12A (100 VAC)
8A (200 VAC)
Maximum heat dissipation
3960 BTU/hr (100 VAC)
5450 BTU/hr (200 VAC)
Power supply output
910 W (low line)
1300 W (high line)
Environment
Temperature
Operating 50 to 95°F (10 to 35°C)
1
Nonoperating -40°F to 158°F (-40°C to 70°C)
1.
At sea level with an altitude derating of 1.8
°
F per every 1000 ft (1.0
°
C per every 3.0m) above sea level to a maximum of
10,000 ft (3050 m). no direct sustained sunlight.
Maximum wet bulb temperature
82.4°F (28°C)
Relative humidity
(noncondensing)
Operating 10% to 90%
Nonoperating 5% to 95%
Altitude
Operating 0 to 10,000 ft (3050 m)
Nonoperating 0 to 30,000 ft (9144 m)
Shock
Operating Half-sine 2 G, 11 ms pulse, 100 pulses
Nonoperating 25 G, 170 inches/sec delta V
Vibration
2.2 Grms, 10 minutes per axis on all three axes