Chapter 5 Maintaining the Cisco 12404 Internet Router
Removing the Chassis from the Equipment Rack
5-48
Cisco 12404 Internet Router Installation and Configuration Guide
OL-11636-01
Transferring the Consolidated Switch Fabric Card
The slot labeled FABRIC ALARM holds the CSF card. This is the bottom slot of
the card cage.
To transfer the CSF card from the defective chassis to the replacement chassis
reinstall the CSF as instructed in the
“Installing a Consolidated Switch Fabric
.
Note
Switch Fabric captive screws must be tightened on the replacement chassis to
ensure electromagnetic compliance (EMC)
Remove each card from the CSF cage, as instructed in the
Consolidated Switch Fabric Card” section on page 5-40
, and install it
immediately in the same slot of the replacement chassis according to the
instructions.
Removing the Chassis from the Equipment Rack
This section contains the following procedures.
•
Detaching the Supplemental Bonding and Grounding Connection, page 5-48
•
Removing the Chassis from the Equipment Rack, page 5-49
•
Removing the Chassis from Center-Mount Brackets, page 5-49
Detaching the Supplemental Bonding and Grounding Connection
You must detach the supplemental bonding and grounding cables from the
defective chassis. See the
“Supplemental Unit Bonding and Grounding
Guidelines” section on page 3-9
.
todd.book Page 48 Tuesday, November 27, 2007 6:02 PM