1-33
Cisco 12404 Internet Router Installation and Configuration Guide
OL-11636-01
Chapter 1 Product Overview
Maintenance Bus
Environmental Monitoring and Alarms
The MBus module on each component monitors that component’s environment as
follows.
•
Line cards and the RP are monitored for temperature by two temperature
sensors mounted on each card. The MBus module makes voltage monitoring
through software; for example the +2.5 VDC, +3.3 VDC, and +5 VDC
DC–to–DC converters.
•
The CSF card is monitored for temperature by two temperature sensors
mounted on the card. The MBus module performs voltage monitoring through
software (for example, the +2.5 VDC and +3.3 VDC).
•
Voltage monitoring the for +5 VDC, for example; is made by the alarm MBus
module on the CSF card.
•
Environmental monitoring includes voltage and current monitoring,
temperature monitoring, and sensing for fan power and RPM.
todd.book Page 33 Tuesday, November 27, 2007 6:02 PM