10. Heat radiation data
When in use, all Fluidmesh gateway units and radio transceivers generate
heat as a by-product of electrical activity.
Heat radiated by a Fluidmesh device may be of concern in confined
locations such as server rooms (where the cumulative heat generated by
a collection of electrical and electronic devices may cause damage to
sensitive electronic components) and outdoor equipment enclosures (in
which electronic components may overheat if the enclosure is not properly
ventilated).
WARNING
The outer surfaces of some Fluidmesh units may become hot
during normal operation. Such units have a 'Hot Surfaces'
warning triangle on their outer enclosures.
During normal operation, do not touch or handle such unit
enclosures without personal protective equipment.
The following table shows nominal heat-radiation figures for all Fluidmesh
devices under idle conditions, and under full-load conditions.
All heat-radiation figures are given in British Thermal Units (BTU) per
hour.
Device
Fiber-
optic
module
installed
Idle @
115 Vac /
60 Hz
Idle @
230 Vac /
60 Hz
Full load
@ 115
Vac / 60
Hz
Full load
@ 230
Vac / 60
Hz
FM1000 Gateway
25.590
33.780
25.250
33.100
FM10000
Gateway (first and
second
generations)
271.595
267.159
436.395
437.078
FM Ponte kit
(model FM1200V-
HW)
6.479
6.138
19.778
19.437
FM1200 Volo
(model FM1200V-
HW)
6.479
6.138
19.778
19.437
All 3200-series
transceivers
(model FM3200)
10.230
10.230
24.552
24.552
FM3500 Endo
(model FM3500)
9.889
9.889
26.939
26.939
FM4200 Mobi
(model FM4200)
10.230
10.230
24.552
24.552
FM4200 Fiber
(model FM4200F)
No
12.617
12.617
26.939
26.939
Heat radiation data
© 2021 Cisco and/or its affiliates. All rights reserved.
Page 125 of 138