The Cisco ASR 920-24SZ-IM, ASR-920-24SZ-M, ASR-920-24TZ-M Router power supplies are hot-swappable.
If you have installed redundant power supplies, you can replace a single power supply without interrupting
power to the router.
Note
To avoid erroneous failure messages, allow at least 2 minutes for the system to reinitialize after a power supply
has been removed or replaced.
Caution
When you install the unit, the ground connection must always be made first and disconnected last. Statement
1046
Warning
Before performing any of the following procedures, ensure that power is removed from the DC circuit.
Statement 1003
Warning
Only trained and qualified personnel should be allowed to install, replace, or service this equipment. Statement
1030
Warning
Installation of the equipment must comply with local and national electrical codes. Statement 1074
Warning
Follow these steps to remove and replace an AC power supply:
Procedure
Step 1
Disconnect the power cord from the power source. Do not touch the metal prongs on the power cord when it
is still connected to the power supply.
Step 2
Remove the power cord from the power connection on the power supply. Do not touch the metal prongs
embedded in the power supply.
Step 3
Loosen the captive installation screw as shown in the figure below.
Installing the Router
33
Installing the Router
Removing and Replacing an AC Power Supply