Related Commands
Present ...... 1
Ready state .. 1
Ready bit .... 1
Interrupt .... 0
Reset ........ 0
Power register 0x3F13
AC ........... 1
The command output indicates that a battery cable is connected up (Present......1). The output represents
a well-connected functional cable.
CGR1240#
show platform battery details
Battery pack state: Operational
Battery pack state: Operational
Battery unit 0 1 2
---------------------------+-----------+-----------+-----------
BatteryStatus ............ 0x80 0xA0 0x80
UnitStatus ............... 0x5830 0x4801 0x2802
BootloaderStatus ......... 0xB 0xB 0xB
InterruptStatus .......... 0x0 0x0 0x0
ChargeStatus ............. 0xC010 0xC010 0xC010
ControlOverride .-........ 0x0 0x0 0x0
AbsoluteStateOfCharge .... 89 % 97 % 90 %
RelativeStateOfCharge .... 89 % 97 % 90 %
RemainingCapacity .. (mAh) 5124 5601 5221
FullChargeCapacity . (mAh) 5739 5739 5739
AverageTimeToEmpty . (min) 65535 65535 65535
AverageTimeToFull .. (min) 65535 65535 65535
RunTimeToEmpty ..... (min) 65535 65535 65535
AtRateTimeToFull ... (min) 65535 65535 65535
AtRateTimeToEmpty .. (min) 65535 65535 65535
AtRateOK ................. 1 1 1
Voltage ............. (mV) 11669 11913 11721
Current ............. (mA) 0 0 0
AverageCurrent ...... (mA) 0 0 0
ChargingCurrent ..... (mA) 0 0 0
ChargingVoltage ..... (mV) 11669 11913 11721
CycleCount ............... 1 6 6
ChargeAlarmWarning ....... 128 160 128
HeaterAndStatusControl ... 0 0 0
HeaterTemperature ... ('C) 30 31 30
AmbientTemperature .. ('C) 29 30 29
Temperature ......... ('C) 30 31 30
Firmware version ......... 5213 5213 5213
UART delay stats rx=2772us, tx=23us
Total charge ................ 92%
Low level ................... 0
Average time to empty (hh:mm) 12:28
Last time to empty readings ( 751 751 746 751 742 minutes )
Needs firmware upgrade ...... 0
Firmware upgd failures ...... 0
Power-off module when running on battery:
Module 3 ............. no
Module 4 ............. no
Module 5 ............. no
Module 6 ............. no
The command output has a range of battery status information including charge capacity, voltage and