Catalyst 6500 Series Ethernet Modules 
Installation Guide

 

September 2010

Text Part Number: OL-6265-03

Summary of Contents for 6513 - Catalyst Switch

Page 1: ...ystems Inc 170 West Tasman Drive San Jose CA 95134 1706 USA http www cisco com Tel 408 526 4000 800 553 NETS 6387 Fax 408 527 0883 Catalyst 6500 Series Ethernet Modules Installation Guide September 2010 Text Part Number OL 6265 03 ...

Page 2: ...ations and you may be required to correct any interference to radio or television communications at your own expense You can determine whether your equipment is causing interference by turning it off If the interference stops it was probably caused by the Cisco equipment or one of its peripheral devices If the equipment causes interference to radio or television reception try to correct the interf...

Page 3: ...atalyst 6509 NEB A Switch 1 40 Catalyst 6509 V E Switch 1 45 Catalyst 6513 Switch 1 49 Catalyst 6513 E Switch 1 54 C H A P T E R 2 Ethernet Switching Modules 2 1 10 and 10 100 Fiber Based Ethernet Modules 2 1 WS X6024 10FL MT Ethernet Module 2 2 WS X6148 FE SFP Ethernet Module 2 4 WS X6324 100FX MM and WS X6324 100FX SM Ethernet Modules 2 7 WS X6524 100FX MM Ethernet Module 2 10 10 100 and 10 100 ...

Page 4: ... 2 92 WS X6716 10G 3C and WS X6716 10G 3CXL Ethernet Modules 2 96 WS X6716 10T 3C and WS X6716 10T 3CXL Ethernet Modules 2 100 C H A P T E R 3 Installing Ethernet Switching Modules 3 1 Safety 3 1 Installing an Ethernet Switching Module 3 2 Required Tools 3 2 Installing an Ethernet Switching Module 3 2 Removing an Ethernet Switching Module 3 10 Installing Pluggable Transceivers 3 11 Installing GBIC...

Page 5: ...d Distributed Forwarding Daughter Cards A 3 A P P E N D I X B Pluggable Transceiver Modules B 1 100 MB Transceivers B 1 1 GB Transceivers B 3 1 GB GBIC Transceivers B 4 1 GB SFP Transceivers B 6 10 GB Transceivers B 8 XENPAK Transceivers B 9 X2 Transceivers B 12 WDM Transceivers B 15 A P P E N D I X C ESD Precautions C 1 Attaching Your ESD Grounding Strap C 1 I N D E X ...

Page 6: ...Contents vi Catalyst 6500 Series Ethernet Modules Installation Guide OL 6265 03 ...

Page 7: ...1 Catalyst 6500 Series Switch Chassis Overview Describes and lists the hardware features and functionality of the Catalyst 6500 series switch chassis Chapter 2 Ethernet Switching Modules Provides descriptions and specifications for the Ethernet modules available for installation on the Catalyst 6500 series switch chassis Chapter 3 Installing Ethernet Switching Modules Provides procedures on how to...

Page 8: ...e Ethernet modules Appendix C ESD Precautions Provides a brief description of the hazards of electrostatic staic discharge ESD and procedures for correctly attaching an ESD wrist strap to the chassis Chapter Title Description Convention Description boldface font Commands command options and keywords are in boldface italic font Arguments for which you supply values are in italics Elements in square...

Page 9: ...something that could result in equipment damage or loss of data screen font Terminal sessions and information the system displays are in screen font boldface screen font Information you must enter is in boldface screen font italic screen font Arguments for which you supply values are in italic screen font The symbol represents the key labeled Control For example the key combination D in a screen d...

Page 10: ...rklaring onderaan de waarschuwing als u een vertaling van de waarschuwing die bij het apparaat wordt geleverd wilt raadplegen BEWAAR DEZE INSTRUCTIES Varoitus TÄRKEITÄ TURVALLISUUSOHJEITA Tämä varoitusmerkki merkitsee vaaraa Tilanne voi aiheuttaa ruumiillisia vammoja Ennen kuin käsittelet laitteistoa huomioi sähköpiirien käsittelemiseen liittyvät riskit ja tutustu onnettomuuksien yleisiin ehkäisyt...

Page 11: ...r fare Du er i en situasjon som kan føre til skade på person Før du begynner å arbeide med noe av utstyret må du være oppmerksom på farene forbundet med elektriske kretser og kjenne til standardprosedyrer for å forhindre ulykker Bruk nummeret i slutten av hver advarsel for å finne oversettelsen i de oversatte sikkerhetsadvarslene som fulgte med denne enheten TA VARE PÅ DISSE INSTRUKSJONENE Aviso I...

Page 12: ...r dig i en situation som kan leda till personskada Innan du utför arbete på någon utrustning måste du vara medveten om farorna med elkretsar och känna till vanliga förfaranden för att förebygga olyckor Använd det nummer som finns i slutet av varje varning för att hitta dess översättning i de översatta säkerhetsvarningar som medföljer denna anordning SPARA DESSA ANVISNINGAR ...

Page 13: ... declaração fornecido ao final de cada aviso para localizar sua tradução nos avisos de segurança traduzidos que acompanham o dispositivo GUARDE ESTAS INSTRUÇÕES Advarsel VIGTIGE SIKKERHEDSANVISNINGER Dette advarselssymbol betyder fare Du befinder dig i en situation med risiko for legemesbeskadigelse Før du begynder arbejde på udstyr skal du være opmærksom på de involverede risici der er ved elektr...

Page 14: ...xii Catalyst 6500 Series Ethernet Modules Installation Guide OL 6265 03 Preface Conventions ...

Page 15: ...ware Configuration Guide Catalyst 6500 Series Switch Module Installation Guide Catalyst 6500 Series Switch Software Configuration Guide Catalyst 6500 Series Switch Command Reference Catalyst 6500 Series Switch Cisco IOS Software Configuration Guide Catalyst 6500 Series Switch Cisco IOS Command Reference ATM Software Configuration and Command Reference Catalyst 5000 Family and Catalyst 6000 Family ...

Page 16: ...formation see the monthly What s New in Cisco Product Documentation which also lists all new and revised Cisco technical documentation at http www cisco com en US docs general whatsnew whatsnew html Subscribe to the What s New in Cisco Product Documentation as a Really Simple Syndication RSS feed and set content to be delivered directly to your desktop using a reader application The RSS feeds are ...

Page 17: ... 6504 E Switch page 1 11 Catalyst 6506 Switch page 1 15 Catalyst 6506 E Switch page 1 20 Catalyst 6509 Switch page 1 25 Catalyst 6509 E Switch page 1 30 Catalyst 6509 NEB Switch page 1 35 Catalyst 6509 NEB A Switch page 1 40 Catalyst 6509 V E Switch page 1 45 Catalyst 6513 Switch page 1 49 Catalyst 6513 E Switch page 1 54 Note Throughout this publication except where noted the term supervisor engi...

Page 18: ...bottom Fan assembly PEM 1 PEM 2 ESD ground strap connection Supervisor Engine Modules WS X6516 GE T X 16 PORT 1000 BASE T GE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 LI NK LI NK LI NK LI NK LI NK LI NK LI NK LI NK LI NK LI NK LI NK LI NK LI NK LI NK LI NK LI NK WS X6516 GE T X 16 PORT 1000 BASE T GE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 LI NK LI NK LI NK LI NK LI NK LI NK LI NK LI NK LI NK LI NK LI...

Page 19: ...tion Guide Installed power supplies can be of different wattage ratings Installed power supplies can be both AC input both DC input or one AC input and one DC input Power supplies can be configured in either redundant or nonredundant mode Note For Catalyst 6503 and Catalyst 6503 E chassis that are equipped with DC input power supplies the system NEBS ground serves as the primary safety ground and ...

Page 20: ...sor Engine 720 and cannot be installed in the same chassis Supervisor Engine 32 and Supervisor Engine 32 PISA do not support the Switch Fabric Modules WS C6500 SFM and WS X6500 SFM2 The uplink ports are fully functional on the redundant supervisor engine while it is in standby mode Note In systems with redundant supervisor engines both supervisor engines must be the same model and have the same da...

Page 21: ...ies modules Are not supported Require that you install a Supervisor Engine 720 Have chassis slot restrictions Require a specific software release level Check your software release notes for specific information on module support Port density including supervisor engine ports 10 Gigabit Ethernet 2 ports Gigabit Ethernet SFP transceivers 8 ports Gigabit Ethernet GBIC transceivers 34 ports 10 100 100...

Page 22: ... and tested for operation 200 to 10 000 feet 60 to 3000 m Physical Characteristics Dimensions H x W x D 7 x 17 37 x 21 75 in 17 78 x 44 12 x 55 25 cm Chassis requires 4 RU Chassis can be mounted in equipment racks that meet ANSI EIA 310 D and ETS 300 119 standards Weight Chassis only 27 lb 12 25 kg Chassis fully configured with 1 supervisor engine 2 modules 2 AC input PEMs and 2 AC input power sup...

Page 23: ... to bottom Fan assembly PEM 1 PEM 2 ESD ground strap connection Supervisor Engine Modules WS X6516 GE T X 16 PORT 1000 BASE T GE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 LI NK LI NK LI NK LI NK LI NK LI NK LI NK LI NK LI NK LI NK LI NK LI NK LI NK LI NK LI NK LI NK WS X6516 GE T X 16 PORT 1000 BASE T GE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 LI NK LI NK LI NK LI NK LI NK LI NK LI NK LI NK LI NK LI N...

Page 24: ... installed in the lower power supply bay The second power supply is installed in the upper power supply bay Supervisor engines Supports Supervisor Engine 2 Supervisor Engine 32 Supervisor Engine 32 PISA Supervisor Engine 720 and Supervisor Engine 720 10GE Supervisor engines are installed in slot 1 and slot 2 Supervisor Engine 720 and Supervisor Engine 720 10GE have built in switching fabric Switch...

Page 25: ...re not supported Require that you install a Supervisor Engine 720 Have chassis slot restrictions Require a specific software release level Check your software release notes for specific information on supported modules Port density including supervisor engine ports 10 Gigabit Ethernet 8 ports Gigabit Ethernet SFP transceivers 98 ports Gigabit Ethernet GBIC transceivers 34 ports 10 100 1000 Etherne...

Page 26: ...0 to 6500 feet 0 to 2000 m Designed and tested for operation 200 to 10 000 feet 60 to 3000 m Physical Characteristics Dimensions H x W x D 7 x 17 37 x 21 75 in 17 78 x 44 12 x 55 25 cm Chassis requires 4 RU Chassis can be mounted in equipment racks that meet ANSI EIA 310 D and ETS 300 119 standards Weight Chassis only 33 lb 15 kg Chassis fully configured with 1 supervisor engine 2 modules 2 AC inp...

Page 27: ...res Table 1 6 lists the specifications of the Catalyst 6504 E switch chassis Figure 1 5 Catalyst 6504 E Switch Front View Figure 1 6 Catalyst 6504 E Switch Rear View 126559 STATUS FAN STATUS STATUS Slots 1 4 top to bottom Supervisor Engine OSMs Redundant Supervisor Engine 126560 PWR 2700 AC INPUT OK FAN OK OUTPUT FAIL ALL FASTENERS MUST BE FULLY ENGAGED PRIOR TO OPERATING THE POWER SUPPLY 100 240V...

Page 28: ...cond power supply is installed in the upper power supply bay Supervisor engines Supports Supervisor Engine 2 Supervisor Engine 32 Supervisor Engine 32 PISA Supervisor Engine 720 and Supervisor Engine 720 10GE Supervisor engines are installed in slot 1 and slot 2 Supervisor Engine 720 and Supervisor Engine 720 10GE have built in switching fabric Switch Fabric Modules WS C6500 SFM and WS X6500 SFM2 ...

Page 29: ...e not supported Require that you install a Supervisor Engine 720 Have chassis slot restrictions Require a specific software release level Check your software release notes for specific information on supported modules Port density including supervisor engine ports 10 Gigabit Ethernet 12 ports Gigabit Ethernet SFP transceivers 144 ports Gigabit Ethernet GBIC transceivers 50 ports 10 100 1000 Ethern...

Page 30: ...eration 0 to 6500 feet 0 to 2000 m Designed and tested for operation 200 to 10 000 feet 60 to 3000 m Physical Characteristics Dimensions H x W x D 8 7 x 17 5 x 21 6 in 22 09 x 44 45 x 54 86 cm Chassis requires 5 RU Chassis can be mounted in equipment racks that meet ANSI EIA 310 D and ETS 300 119 standards Weight Chassis only 27 lb 12 25 kg Chassis fully configured with 2 supervisor engines 2 modu...

Page 31: ...T US 2 3 4 5 6 7 8 LI NK LI NK LI NK LI NK LI NK LI NK LI NK 8 PORT GIGABIT ETHERNET WS X6408 1 LI NK ST AT US 2 3 4 5 6 7 8 LI NK LI NK LI NK LI NK LI NK LI NK LI NK 8 PORT GIGABIT ETHERNET WS X6408 1 LI NK ST AT US 2 3 4 5 6 7 8 LI NK LI NK LI NK LI NK LI NK LI NK LI NK WS SUP32 GE 3B ST AT US SY ST EM AC TIVE PW R MGMT RE SE T CATALYST 6500 SUPERVISOR ENGINE 32 CONSOLE EJECT DISK 0 PORT 1 PORT ...

Page 32: ...nd the 8700 W AC input power supplies are limited to 4500 W maximum output when installed in the Catalyst 6506 chassis Note For information and specifications for each of the supported power supplies refer to Appendix A Power Supply Specifications in the Catalyst 6500 Series Switches Installation Guide Installed power supplies can be of different wattage ratings Installed power supplies can also b...

Page 33: ...720 and Supervisor Engine 720 10GE have built in switching fabric Switch Fabric Modules WS C6500 SFM and WS X6500 SFM2 are not supported by Supervisor Engine 720 and Supervisor Engine 720 10GE and cannot be installed in the same chassis Supervisor Engine 32 and Supervisor Engine 32 PISA do not support the Switch Fabric Modules WS C6500 SFM and WS X6500 SFM2 The uplink ports are fully functional on...

Page 34: ...s Are not supported Require that you install a Supervisor Engine 720 Have chassis slot restrictions Require a specific software release level Check your software release notes for specific information on supported modules Port density including supervisor engine ports 10 Gigabit Ethernet 20 ports Gigabit Ethernet SFP transceivers 242 ports Gigabit Ethernet GBIC transceivers 82 ports 10 100 1000 Et...

Page 35: ...200 to 10 000 feet 60 to 3000 m Physical Characteristics Dimensions H x W x D 20 1 x 17 2 x 18 1 in 51 1 x 43 7 x 46 0 cm Chassis depth including cable guide is 21 64 in 55 0 cm Chassis requires 12 RU Chassis can be mounted in equipment racks that meet ANSI EIA 310 D and ETS 300 119 standards Weight Chassis only 45 lb 20 4 kg Chassis fully configured with 1 supervisor engine 5 switching modules an...

Page 36: ... ST AT US 2 3 4 5 6 7 8 LI NK LI NK LI NK LI NK LI NK LI NK LI NK 8 PORT GIGABIT ETHERNET WS X6408 1 LI NK ST AT US 2 3 4 5 6 7 8 LI NK LI NK LI NK LI NK LI NK LI NK LI NK 8 PORT GIGABIT ETHERNET WS X6408 1 LI NK ST AT US 2 3 4 5 6 7 8 LI NK LI NK LI NK LI NK LI NK LI NK LI NK WS SUP32 GE 3B ST AT US SY ST EM AC TIVE PW R MGMT RE SE T CATALYST 6500 SUPERVISOR ENGINE 32 CONSOLE EJECT DISK 0 PORT 1 ...

Page 37: ...AC input power supply WS CAC 8700W E 8700 W AC input power supply Note For information and specifications for each of the supported power supplies refer to Appendix A Power Supply Specifications in the Catalyst 6500 Series Switches Installation Guide Installed power supplies can be of different wattage ratings Installed power supplies can also be both AC input both DC input or one AC input and one...

Page 38: ... be installed in the same chassis Supervisor Engine 32 and Supervisor Engine 32 PISA do not support the Switch Fabric Modules WS C6500 SFM and WS X6500 SFM2 The uplink ports are fully functional on the redundant supervisor engine in standby mode Note In systems with redundant supervisor engines both supervisor engines must be the same model and have the same daughter card configurations Each super...

Page 39: ...s Are not supported Require that you install a Supervisor Engine 720 Have chassis slot restrictions Require a specific software release level Check your software release notes for specific information on supported modules Port density including supervisor engine ports 10 Gigabit Ethernet 20 ports Gigabit Ethernet SFP transceivers 242 ports Gigabit Ethernet GBIC transceivers 82 ports 10 100 1000 Et...

Page 40: ...2000 m Designed and tested for operation 200 to 10 000 feet 60 to 3000 m Physical Characteristics Dimensions H x W x D 19 2 x 17 5 x 18 2 in 48 8 x 44 5 x 46 0 cm Chassis depth including cable guide is 21 64 in 55 0 cm Chassis requires 12 RU Chassis can be mounted in equipment racks that meet ANSI EIA 310 D and ETS 300 119 standards Weight Chassis only 45 lb 20 41 kg Chassis fully configured with ...

Page 41: ... 6 7 8 LI N K LI N K LI N K LI N K LI N K LI N K LI N K 8 PORT GIGABIT ETHERNET WS X6408 1 LI NK ST AT US 2 3 4 5 6 7 8 LI NK LI NK LI NK LI NK LI NK LI NK LI NK 24 PORT 100FX WS X6224 ST AT US 24 PORT 100FX WS X6224 ST AT US 1 LI NK 2 LI NK 3 LI NK 4 LI NK 5 LI NK 6 LI NK 7 LI NK 8 LI NK 9 LI NK 10 LI NK 11 LI NK 12 LI NK 13 LI NK 14 LI NK 15 LI NK 16 LI NK 17 LI NK 18 LI NK 19 LI NK 20 LI NK 21 ...

Page 42: ...he 8700 W AC input power supplies are limited to 4500 W maximum output when installed in the Catalyst 6509 chassis Note For information and specifications for each of the supported power supplies refer to Appendix A Power Supply Specifications in the Catalyst 6500 Series Switches Installation Guide Installed power supplies can be of different wattage ratings Installed power supplies can also be bo...

Page 43: ... Engine 720 10GE have built in switching fabric Switch Fabric Modules WS C6500 SFM and WS X6500 SFM2 are not supported by Supervisor Engine 720 and Supervisor Engine 720 10GE and cannot be installed in the same chassis Supervisor Engine 32 and Supervisor Engine 32 PISA do not support the Switch Fabric Modules WS C6500 SFM and WS X6500 SFM2 The uplink ports are fully functional on all redundant sup...

Page 44: ...s Are not supported Require that you install a Supervisor Engine 720 Have chassis slot restrictions Require a specific software release level Check your software release notes for specific information on supported modules Port density including supervisor engine ports 10 Gigabit Ethernet 32 ports Gigabit Ethernet SFP transceivers 386 ports Gigabit Ethernet GBIC transceivers 130 ports 10 100 1000 E...

Page 45: ...tion 200 to 10 000 feet 60 to 3000 m Physical Characteristics Dimensions H x W x D 25 2 x 17 2 x 18 4 in 64 0 x 43 7 x 46 7 cm Chassis depth including cable guide is 21 64 in 55 0 cm Chassis requires 15 RU Chassis can be mounted in equipment racks that meet ANSI EIA 310 D and ETS 300 119 standards Weight Chassis only 55 lb 24 9 kg Chassis fully configured with 1 supervisor engine 8 switching modul...

Page 46: ... U S 2 3 4 5 6 7 8 LI N K LI N K LI N K LI N K LI N K LI N K LI N K 8 PORT GIGABIT ETHERNET WS X6408 1 LI NK ST AT US 2 3 4 5 6 7 8 LI NK LI NK LI NK LI NK LI NK LI NK LI NK 24 PORT 100FX WS X6224 ST AT US 24 PORT 100FX WS X6224 ST AT US 1 LI NK 2 LI NK 3 LI NK 4 LI NK 5 LI NK 6 LI NK 7 LI NK 8 LI NK 9 LI NK 10 LI NK 11 LI NK 12 LI NK 13 LI NK 14 LI NK 15 LI NK 16 LI NK 17 LI NK 18 LI NK 19 LI NK ...

Page 47: ...upply PWR 4000 DC 4000 W DC input power supply WS CAC 6000W 6000 W AC input power supply WS CAC 8700W E 8700 W AC input power supply Note For information and specifications for each of the supported power supplies refer to Appendix A Power Supply Specifications in the Catalyst 6500 Series Switches Installation Guide Installed power supplies can be of different wattage ratings Installed power suppl...

Page 48: ...led in the same chassis Supervisor Engine 32 and Supervisor Engine 32 PISA do not support the Switch Fabric Modules WS C6500 SFM and WS X6500 SFM2 The uplink ports are fully functional on all redundant supervisor engine models when they are in standby mode Note In systems with redundant supervisor engines both supervisor engines must be the same model and have the same daughter card configurations...

Page 49: ...s Are not supported Require that you install a Supervisor Engine 720 Have chassis slot restrictions Require a specific software release level Check your software release notes for specific information on supported modules Port density including supervisor engine ports 10 Gigabit Ethernet 32 ports Gigabit Ethernet SFP transceivers 386 ports Gigabit Ethernet GBIC transceivers 130 ports 10 100 1000 E...

Page 50: ...2000 m Designed and tested for operation 200 to 10 000 feet 60 to 3000 m Physical Characteristics Dimensions H x W x D 24 5 x 17 5 x 18 2 in 62 2 x 44 5 x 46 0 cm Chassis depth including cable guide is 21 64 in 55 0 cm Chassis requires 15 RU Chassis can be mounted in equipment racks that meet ANSI EIA 310 D and ETS 300 119 standards Weight Chassis only 55 lb 24 9 kg Chassis fully configured with 1...

Page 51: ...3 LI N K 4 LI N K 5 LI N K 6 LI N K 7 LI N K 8 LI N K 9 LI N K 10 LI N K 11 LI N K 12 LI N K 13 LI N K 14 LI N K 15 LI N K 16 LI N K 17 LI N K 18 LI N K 19 LI N K 20 LI N K 21 LI N K 22 LI N K 23 LI N K 24 LI N K Slots 1 9 right to left Power supply 1 Power supply 2 redundant ESD ground strap connection WS SUP32 GE 3B ST AT US SY ST EM AC TIV E PW R MG MT RE SE T CATALYST 6500 SUPERVISOR ENGINE 32...

Page 52: ... The 6000 W and the 8700 W AC input power supplies are limited to 4500 W maximum output when installed in the Catalyst 6509 NEB chassis Note For information and specifications for each of the supported power supplies refer to Appendix A Power Supply Specifications in the Catalyst 6500 Series Switches Installation Guide Installed power supplies can be of different wattage ratings Installed power su...

Page 53: ...6500 SFM and WS X6500 SFM2 are not supported by Supervisor Engine 720 and cannot be installed in the same chassis Supervisor Engine 32 and Supervisor Engine 32 PISA do not support the Switch Fabric Modules WS C6500 SFM and WS X6500 SFM2 The uplink ports are fully functional on all redundant supervisor engine models when they are in standby mode Note In systems with redundant supervisor engines bot...

Page 54: ...es Are not supported Require that you install a Supervisor Engine 720 Have chassis slot restrictions Require a specific software release level Check your software release notes for specific information on supported modules Port density including supervisor engine ports 10 Gigabit Ethernet 32 ports Gigabit Ethernet SFP transceivers 384 ports Gigabit Ethernet GBIC transceivers 130 ports 10 100 1000 ...

Page 55: ...nd tested for operation 200 to 10 000 feet 60 to 3000 m Physical Characteristics Dimensions H x W x D 33 3 x 17 2 x 18 1 in 84 6 x 43 7 x 46 0 cm Chassis requires 20 RU Chassis can be mounted in equipment racks that meet ANSI EIA 310 D and ETS 300 119 standards Weight Chassis only 55 lb 24 9 kg Chassis fully configured with 1 supervisor engine 8 switching modules and 2 power supplies 135 lb 61 2 k...

Page 56: ...6 35 36 37 38 47 48 WS X6548 GE TX STATUS 48 PORT 10 100 1000 BASE T GE SWITCHING MODULE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 PHONE 1 2 11 12 13 14 23 24 25 26 35 36 37 38 47 48 WS X6548 GE TX STATUS 48 PORT 10 100 1000 BASE T GE SWITCHING MODULE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 2...

Page 57: ... W AC input power supply WS CAC 8700W E 8700 W AC input power supply Note The 6000 W and the 8700 W AC input power supplies are limited to 4500 W maximum output when installed in the Catalyst 6509 NEB A chassis Note For information and specifications for each of the supported power supplies refer to Appendix A Power Supply Specifications in the Catalyst 6500 Series Switches Installation Guide Inst...

Page 58: ...led in the same chassis Supervisor Engine 32 and Supervisor Engine 32 PISA do not support the Switch Fabric Modules WS C6500 SFM and WS X6500 SFM2 The uplink ports are fully functional on all redundant supervisor engine models when they are in standby mode Note In systems with redundant supervisor engines both supervisor engines must be the same model and have the same daughter card configurations...

Page 59: ...s Are not supported Require that you install a Supervisor Engine 720 Have chassis slot restrictions Require a specific software release level Check your software release notes for specific information on supported modules Port density including supervisor engine ports 10 Gigabit Ethernet 32 ports Gigabit Ethernet SFP transceivers 386 ports Gigabit Ethernet GBIC transceivers 130 ports 10 100 1000 E...

Page 60: ...tion 0 to 6500 feet 0 to 2000 m Designed and tested for operation 200 to 10 000 feet 60 to 3000 m Physical Characteristics Dimensions H x W x D 36 7 x 17 2 x 20 3 in 93 1 x 43 7 x 51 6 cm Chassis requires 21 RU Chassis can be mounted in equipment racks that meet ANSI EIA 310 D and ETS 300 119 standards Weight Chassis only 121 lb 54 9 kg Chassis fully configured with 1 supervisor engine 8 modules 2...

Page 61: ...36 37 38 47 48 WS X6548 GE TX STATUS 48 PORT 10 100 1000 BASE T GE SWITCHING MODULE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 PHONE 1 2 11 12 13 14 23 24 25 26 35 36 37 38 47 48 WS X6548 GE TX STATUS 48 PORT 10 100 1000 BASE T GE SWITCHING MODULE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 ...

Page 62: ...ly PWR 4000 DC 4000 W DC input power supply WS CAC 6000W 6000 W AC input power supply WS CAC 8700W E 8700 W AC input power supply Note For information and specifications for each of the supported power supplies refer to Appendix A Power Supply Specifications in the Catalyst 6500 Series Switches Installation Guide Installed power supplies can be of different ratings Installed power supplies can als...

Page 63: ...the same model and have the same daughter card configurations Each supervisor engine must have the resources to run the switch on its own which means all supervisor engine resources are duplicated Identical supervisor engine memory configurations are recommended but are not required as long as the supervisor engine with the smaller memory configuration is sufficient to run the configured features ...

Page 64: ...0 to 6500 feet 0 to 2000 m Designed and tested for operation 200 to 10 000 feet 60 to 3000 m Physical Characteristics Dimensions H x W x D 36 7 x 17 2 x 20 3 in 93 1 x 43 7 x 51 6 cm Chassis requires 21 RU Chassis can be mounted in equipment racks that meet ANSI EIA 310 D and ETS 300 119 standards Weight Chassis only 121 lb 54 9 kg Chassis fully configured with 1 supervisor engine 8 modules 2 AC i...

Page 65: ...K 3 LIN K 4 LIN K 5 LIN K 6 LIN K 7 LIN K 8 LIN K 9 LIN K 10 LIN K 11 LIN K 12 LIN K 13 LIN K 14 LIN K 15 LIN K 16 LIN K 17 LIN K 18 LIN K 19 LIN K 20 LIN K 21 LIN K 22 LIN K 23 LIN K 24 LIN K 1 LIN K 2 LIN K 3 LIN K 4 LIN K 5 LIN K 6 LIN K 7 LIN K 8 LIN K 9 LIN K 10 LIN K 11 LIN K 12 LIN K 13 LIN K 14 LIN K 15 LIN K 16 LIN K 17 LIN K 18 LIN K 19 LIN K 20 LIN K 21 LIN K 22 LIN K 23 LIN K 24 LIN K ...

Page 66: ...supply Note For information and specifications for each of the supported power supplies refer to Appendix A Power Supply Specifications in the Catalyst 6500 Series Switches Installation Guide The 8700 W AC input power supply is limited to 6000 W when it is installed in a Catalyst 6513 switch chassis Installed power supplies can be of different ratings Installed power supplies can also be both AC i...

Page 67: ...abric Switch Fabric Modules WS C6500 SFM and WS X6500 SFM2 are not supported by Supervisor Engine 720 and Supervisor Engine 720 10GE and cannot be installed in the same chassis Supervisor Engine 32 and Supervisor Engine 32 PISA do not support the Switch Fabric Modules WS C6500 SFM and WS X6500 SFM2 The uplink ports are fully functional on all redundant supervisor engine models when they are in sta...

Page 68: ...t a single fabric channel slots 9 13 support dual fabric channels Some Catalyst 6500 series modules Are not supported Require that you install a Supervisor Engine 720 Have chassis slot restrictions Require a specific software release level Check your software release notes for specific information on supported modules Port density including supervisor engine ports 10 Gigabit Ethernet 20 ports Giga...

Page 69: ... 2000 m Designed and tested for operation 200 to 10 000 feet 60 to 3000 m Physical Characteristics Dimensions H x W x D 33 3 x 17 2 x 18 1 in 84 6 x 43 7 x 46 0 cm Chassis requires 20 RU Chassis can be mounted in equipment racks that meet ANSI EIA 310 D and ETS 300 119 standards Weight Chassis fully configured with 2 supervisor engines 11 switching modules and 2 power supplies 280 lb 127 kg Airflo...

Page 70: ...N K 6 LIN K 7 LIN K 8 LIN K 9 LIN K 10 LIN K 11 LIN K 12 LIN K 13 LIN K 14 LIN K 15 LIN K 16 LIN K 17 LIN K 18 LIN K 19 LIN K 20 LIN K 21 LIN K 22 LIN K 23 LIN K 24 LIN K 1 LIN K 2 LIN K 3 LIN K 4 LIN K 5 LIN K 6 LIN K 7 LIN K 8 LIN K 9 LIN K 10 LIN K 11 LIN K 12 LIN K 13 LIN K 14 LIN K 15 LIN K 16 LIN K 17 LIN K 18 LIN K 19 LIN K 20 LIN K 21 LIN K 22 LIN K 23 LIN K 24 LIN K 1 LIN K 2 LIN K 3 LIN ...

Page 71: ...ower supply WS CAC 6000W 6000 W AC input power supply PWR 6000 DC 6000 W DC input power supply WS CAC 8700W E 8700 W AC input power supply Note For information and specifications for each of the supported power supplies refer to Appendix A Power Supply Specifications in the Catalyst 6500 Series Switches Installation Guide Installed power supplies can be of different ratings Installed power supplie...

Page 72: ... not support the Switch Fabric Modules WS C6500 SFM and WS X6500 SFM2 The uplink ports are fully functional on all redundant supervisor engine models when they are in standby mode Note In systems with redundant supervisor engines both supervisor engines must be the same model and have the same daughter card configurations Each supervisor engine must have the resources to run the switch on its own ...

Page 73: ...l fabric channels Some Catalyst 6500 series modules Are not supported Require that you install a specific supervisor engine Have chassis slot restrictions Require a specific software release level Check your software release notes for specific information on supported modules Port density including supervisor engine ports 10 Gigabit Ethernet 20 ports Gigabit Ethernet SFP transceivers 410 ports Gig...

Page 74: ...tified for operation 0 to 6500 feet 0 to 2000 m Designed and tested for operation 200 to 10 000 feet 60 to 3000 m Physical Characteristics Dimensions H x W x D 33 3 x 17 2 x 18 1 in 84 6 x 43 7 x 46 0 cm Chassis requires 20 RU Chassis can be mounted in equipment racks that meet ANSI EIA 310 D and ETS 300 119 standards Weight Chassis fully configured with 2 supervisor engines 11 switching modules a...

Page 75: ...abit Ethernet Modules page 2 63 10 Gigabit Ethernet Modules page 2 87 Note Service modules are not covered in this document They have their own standalone documentation sets 10 and 10 100 Fiber Based Ethernet Modules This section describes the following 10 and 10 100 fiber based Ethernet modules WS X6024 10FL MT Ethernet Module page 2 2 WS X6148 FE SFP Ethernet Module page 2 4 WS X6324 100FX MM an...

Page 76: ...l or half duplex over 62 5 and 125 micron MMF Buffer size 64 KB per port Maximum frame size Up to 9216 bytes per frame Module oversubscription rate N A Supervisor engine support Supported by the following supervisor engines Supervisor Engine 2 Supervisor Engine 32 Supervisor Engine 32 PISA Supervisor Engine 720 Software support With Supervisor Engine 2 12 2 17d SXB With Supervisor Engine 32 12 2 1...

Page 77: ...ostics pass the module is operational Orange The module is booting or running diagnostics an overtemperature condition has occurred LINK Green The port is active the link is connected and operational Flashing orange The port failed diagnostics and is disabled Orange The port is disabled Red The module is resetting an overtemperature condition has occurred Note If the module fails to download code ...

Page 78: ...eat dissipation 272 52 BTU hour DC input power 85 81 W DC heat dissipation 293 0 BTU hour Environment Operating temperature Certified for operation 32 to 104 F 0 to 40 C Designed and tested for operation 32 to 130 F 0 to 55 C Humidity RH ambient noncondensing 10 to 90 Operating altitude Certified for operation 0 to 6500 ft 0 to 2000 m Designed and tested for operation 200 to 10 000 ft 60 to 3000 m...

Page 79: ...visor Engine 720 10GE Software support With Supervisor Engine 2 12 2 18 SXF2 With Supervisor Engine 32 12 2 18 SXF With Supervisor Engine 32 PISA 12 2 18 ZY With Supervisor Engine 720 12 2 18 SXF With Supervisor Engine 720 10GE 12 2 33 SXH Catalyst OS 8 4 1 Queues per port Tx 1p3q8t per port Rx 1p1q2t per group of 8 ports Chassis slot restrictions No chassis or slot restrictions the module can occ...

Page 80: ...y during the initial reset the LED stays red the module does not come online Off The port is not active or the link is not connected Table 2 4 WS X6148 FE SFP Physical and Environmental Specifications Item Specification Dimensions H x W x D 1 2 x 14 4 x 16 in 3 0 x 35 6 x 40 6 cm Occupies one slot in the chassis Weight 6 6 lb 3 kg Power and heat numbers Module current 2 3 A Module power 96 60 W AC...

Page 81: ...ernet Module Features Feature Description Ports per module 24 ports Ports are numbered 1 left to 24 right 2 port groups Port ranges per port group 1 12 13 24 Port connector type MT RJ both modules Cabling distance WS X6324 100FX MM 1 24 mi 2 km full duplex over MMF WS X6324 100FX MM 1312 ft 400 m half duplex over MMF WS X6324 100FX SM 6 2 mi 10 km full or half duplex over G 652 SMF Buffer size 128...

Page 82: ...ilable Distributed forwarding support Not available Pluggable transceivers support Not supported Digital Optical Monitoring DOM support Not supported Module front panel LEDs STATUS Green All diagnostics pass the module is operational Orange The module is booting or running diagnostics an overtemperature condition has occurred LINK Green The port is active the link is connected and operational Flas...

Page 83: ...upies one slot in the chassis Weight 7 0 lb 3 18 kg Power and heat numbers Module current 1 52 A Module power 63 84 W AC input power 79 8 W AC heat dissipation 272 52 BTU hour DC input power 85 81 W DC heat dissipation 293 03 BTU hour Environment Operating temperature Certified for operation 32 to 104 F 0 to 40 C Designed and tested for operation 32 to 130 F 0 to 55 C Humidity RH ambient nonconden...

Page 84: ...ort QoS Number of egress queues 4 Number of ingress queues 2 Number of thresholds per egress queue 1 Number of thresholds per ingress queue 0 Maximum frame size Up to 9216 bytes per frame Module oversubscription rate N A Supervisor engine support Supported by the following supervisor engines Supervisor Engine 2 Supervisor Engine 32 Supervisor Engine 32 PISA Supervisor Engine 720 Supervisor Engine ...

Page 85: ...atalyst 6500 Series DFC DFC3A DFC3B and DFC3BXL Installation Note for field installation procedures Pluggable transceivers support Not supported Digital Optical Monitoring DOM support Not supported Module front panel LEDs STATUS Green All diagnostics pass the module is operational Orange The module is booting or running diagnostics an overtemperature condition has occurred LINK Green The port is a...

Page 86: ...at numbers Base module Module current 1 90 A Module power 79 8 W AC input power 99 75 W AC heat dissipation 340 65 BTU hour DC input power 107 30 W DC heat dissipation 366 30 BTU hour Base module DFC3 daughter card Module current 4 00 A Module power 168 00 W AC input power 210 00 W AC heat dissipation 717 15 BTU hour DC input power 225 81 W DC heat dissipation 771 13 BTU hour Base module DFC3A dau...

Page 87: ...es page 2 40 Power and heat numbers continued Base module DFC3B daughter card Module current 3 57 A Module power 149 94 W AC input power 187 43 W AC heat dissipation 640 06 BTU hour DC input power 201 53 W DC heat dissipation 688 23 BTU hour Base module DFC3BXL daughter card Module current 3 37 A Module power 141 54 W AC input power 176 93 W AC heat dissipation 604 20 BTU hour DC input power 190 2...

Page 88: ...er will differ Table 2 10 lists the features and descriptions for the base modules and their variants and Table 2 11 lists the physical and environmental specifications for the base modules and their variants Table 2 9 WS X6148 GE TX and WS X6148A GE TX Ethernet Module Variants Module Description WS X6148 GE TX Base module without daughter cards installed WS X6148 GE 45AF Base module equipped with...

Page 89: ...riants Cabling distance 328 ft 100 m over Category 5 5e and 6 UTP STP cable all variants Buffer size WS X6148 GE TX WS X6148V GE TX and WS X6148 GE 45AF 1 4 MB per 8 ports WS X6148A GE TX and WS X6148A GE 45AF 5 5 MB per port QoS Number of egress queues 3 Number of ingress queues 1 Number of thresholds per egress queue 2 Number of thresholds per ingress queue 2 Maximum frame size WS X6148 GE TX WS...

Page 90: ...s the module can occupy any slot in any Catalyst 6500 or Catalyst 6500 E chassis all variants Bus connection Single connection into the 32 Gbps shared bus all variants Module upgrades available PoE support WS X6148 GE TX and WS X6148A GE TX The WS X6148 GE TX is field upgradeable with the WS F6K VPWR GE daughter card that supports only the Cisco prestandard Both the WS X6148 GE TX and the WS X6148...

Page 91: ...ndition has occurred Note If the module fails to download code and configuration information successfully during the initial reset the LED stays red the module does not come online Off The port is not active or the link is not connected PHONE Green The PoE daughter card is installed and detected Off The PoE daughter card is not detected or is not installed Table 2 11 WS X6148 GE TX and Variants Ph...

Page 92: ...n 510 87 BTU hour WS X6148V GE TX base module PoE daughter card Module current 2 89 A Module power 121 38 W AC input power 151 72 W AC heat dissipation 518 14 BTU hour DC input power 163 15 W DC heat dissipation 557 14 BTU hour WS X6148A GE TX enhanced base module Module current 2 50A Module power 105 00 W AC input power 131 25 W AC heat dissipation 448 22 BTU hour DC input power 141 13 W DC heat ...

Page 93: ...X and Variants Physical and Environmental Specifications continued Item Specification Table 2 12 WS X6148 RJ21 Ethernet Module Variants Module Description WS X6148 RJ21 Base module without daughter cards installed WS X6148 21AF Base module equipped with a factory installed IEEE 802 3af PoE daughter card WS F6K GE48 AF WS X6148 RJ21V Base module equipped with a factory installed Cisco prestandard P...

Page 94: ...following supervisor engines Supervisor Engine 2 Supervisor Engine 32 Supervisor Engine 32 PISA Supervisor Engine 720 Supervisor Engine 720 10GE Software support With Supervisor Engine 2 12 1 12c E1 With Supervisor Engine 2 and WS F6K VPWR PoE daughter card 12 1 13 E With Supervisor Engine 32 12 2 18 SXF With Supervisor Engine 32 PISA 12 2 18 ZY With Supervisor Engine 720 except with WS F6K 48 AF ...

Page 95: ...ghter card is not field upgradeable Distributed forwarding support Not available Pluggable transceivers support Not supported TDR support All variants supported Module front panel LEDs STATUS Green All diagnostics pass the module is operational Orange The module is booting or running diagnostics an overtemperature condition has occurred LINK Green The port is active the link is connected and opera...

Page 96: ... dissipation 460 75 BTU hour WS X6148 21AF base module PoE daughter card Module current 2 57 A Module power 107 94 W AC input power 134 93 W AC heat dissipation 460 77 BTU hour DC input power 145 08 W DC heat dissipation 495 45 BTU hour WS X6148 RJ21V base module PoE daughter card Module current 2 39 A Module power 100 38 W AC input power 125 48 W AC heat dissipation 428 50 BTU hour DC input power...

Page 97: ...ns for the modules Table 2 15 WS X6148 RJ 45 and WS X61248A RJ 45 Ethernet Modules and Variants Module Description WS X6148 RJ 45 Base module without daughter cards installed WS X6148 45AF Base module equipped with a factory installed IEEE 802 3af PoE daughter card WS F6K GE48 AF WS X6148 RJ45V Base module equipped with a factory installed Cisco prestandard PoE daughter card WS F6K VPWR GE WS X614...

Page 98: ...ng distance 328 ft 100 m over Category 5 5e and 6 UTP STP cable all variants Buffer size WS X6148 RJ 45 WS X6148 45AF and WS X6148 RJ45V 1 MB per 8 ports WS X6148A RJ 45 and WS X6148A 45AF 5 3 MB per 8 ports QoS Number of egress queues 2 6148 4 6148A Number of ingress queues 1 6148 2 6148A Number of thresholds per egress queue 2 6148 8 6148A Number of thresholds per ingress queue 4 6148 4 6148A Ma...

Page 99: ...8A 45AF Tx 1p3q8t Rx 1q2t Chassis slot restrictions No chassis or slot restrictions the module can occupy any slot in any Catalyst 6500 or Catalyst 6500 E chassis all variants Bus connection Single connection into the 32 Gbps shared bus all variants Module upgrades available PoE support WS X6148 RJ 45 Field upgradeable to the Cisco prestandard only with the WS F6K VPWR GE daughter card or both the...

Page 100: ...ialization sequence An overtemperature condition has occurred A major temperature threshold has been exceeded during environmental monitoring If the module fails to download code and configuration information successfully during the initial reset the LED stays red the module does not come online LINK Green The port is active the link is connected and operational Orange The module or port is disabl...

Page 101: ... 7 2 lb 3 27 kg Power and heat numbers WS X6148 RJ 45 Module current 2 39 A Module power 100 38 W AC input power 125 48 W AC heat dissipation 428 50 BTU hour DC input power 134 92 W DC heat dissipation 460 75 BTU hour WS X6148 45AF base module PoE daughter card Module current 2 57 A Module power 107 94 W AC input power 134 33 W AC heat dissipation 460 77 BTU hour DC input power 145 08 W DC heat di...

Page 102: ...E daughter card Module current 1 42 A Module power 59 64 W AC input power 74 55 W AC heat dissipation 254 59 BTU hour DC input power 80 16 W DC heat dissipation 273 75 BTU hour Environment Operating temperature Certified for operation 32 to 104 F 0 to 40 C Designed and tested for operation 32 to 130 F 0 to 55 C Humidity RH ambient noncondensing 10 to 90 Operating altitude Certified for operation 0...

Page 103: ...Front Panel Figure 2 9 WS F6K 48X2 SPLTR Splitter Panel Table 2 19 lists the features for the modules and Table 2 20 lists the physical and environmental specifications for the module Note With the IEEE 802 3af PoE daughter card installed the WS X6148X2 RJ 45 module can support up to 48 Class 3 15 4 W devices per module when operating as a 48 port module or up to 96 Class 2 7 W devices per module ...

Page 104: ...egory 5 5e and 6 UTP STP cable both modules Buffer size 1 116 MB per port both modules QoS Number of egress queues 4 Number of ingress queues 2 Number of thresholds per egress queue 1 Number of thresholds per ingress queue 0 Maximum frame size Up to 9216 bytes per frame both modules Module oversubscription rate N A Supervisor engine support Supported on the following supervisor engines Supervisor ...

Page 105: ...h the WS F6K FE48X2 AF PoE daughter card Note With the IEEE 802 3af PoE daughter card installed the WS X6148X2 RJ 45 module can support up to 48 Class 3 15 4 W devices per module when operating as a 48 port module or up to 96 Class 2 7 W devices per module when operating as a 96 port module See the Cisco Catalyst 6500 Series Power over Ethernet Daughter Cards Field Upgrade Installation Note for fi...

Page 106: ... An overtemperature condition has occurred A major temperature threshold has been exceeded during environmental monitoring If the module fails to download code and configuration information successfully during the initial reset the LED stays red the module does not come online LINK Green The port is active the link is connected and operational Orange The module or port is disabled through the CLI ...

Page 107: ...numbers WS X6148X2 RJ 45 base module Module current 2 65 A Module power 111 30 W AC input power 139 13 W AC heat dissipation 475 11 BTU hour DC input power 149 60 W DC heat dissipation 510 87 BTU hour WS X6148X2 45AF base module PoE daughter card Module current 3 07 A Module power 128 94 W AC input power 161 18 W AC heat dissipation 550 41 BTU hour DC input power 173 31 W DC heat dissipation 591 8...

Page 108: ...7 5 5 8 5 6 9 5 7 1 0 5 8 1 1 5 9 1 2 6 0 1 3 6 1 1 4 6 2 1 5 6 3 1 6 6 4 1 7 6 5 1 8 6 6 1 9 6 7 2 0 6 8 2 1 6 9 2 2 7 0 2 3 7 1 2 4 7 2 2 5 7 3 2 6 7 4 2 7 7 5 2 8 7 6 2 9 7 7 3 0 7 8 3 1 7 9 3 2 8 0 3 3 8 1 3 4 8 2 3 5 8 3 3 6 8 4 3 7 8 5 3 8 8 6 3 9 8 7 4 0 8 8 4 1 8 9 4 2 9 0 4 3 9 1 4 4 9 2 4 5 9 3 4 6 9 4 4 7 9 5 4 8 INLINE POWER 9 6 1 60 12 49 13 72 24 61 25 84 36 73 37 96 48 85 184595 Tab...

Page 109: ... 12 2 33 SXH Catalyst OS Release 8 2 1 Queues per port Both modules Tx 1p3q1t Rx 1p1q0t Chassis slot restrictions No chassis or slot restrictions the module can occupy any slot in any Catalyst 6500 or Catalyst 6500 E chassis Bus connection 32 Gbps shared bus both modules Module upgrades available PoE support WS X6196 RJ 21 Field upgradeable to both Cisco prestandard and IEEE 802 3af with the WS F6...

Page 110: ...l initialization sequence An overtemperature condition has occurred A major temperature threshold has been exceeded during environmental monitoring If the module fails to download code and configuration information successfully during the initial reset the LED stays red the module does not come online LINK Green The port is active the link is connected and operational Orange The module or port is ...

Page 111: ... Module current 2 74 A Module power 115 08 W AC input power 143 85 W AC heat dissipation 491 25 BTU hour DC input power 154 68 W DC heat dissipation 528 22 BTU hour WS X6196 21AF base module PoE daughter card Module current 3 16 A Module power 132 72 W AC input power 165 90 W AC heat dissipation 566 55 BTU hour DC input power 178 39 W DC heat dissipation 609 19 BTU hour Environment Operating tempe...

Page 112: ...nector Cabling distance 328 ft 100 m over Category 5 5e and 6 UTP STP cable Buffer size 128 KB QoS Number of egress queues 2 Number of ingress queues 1 Number of thresholds per egress queue 2 Number of thresholds per ingress queue 4 Maximum frame size Up to 8092 bytes per frame Module oversubscription rate N A Supervisor engine support Supported on the following supervisor engines Supervisor Engin...

Page 113: ...ture condition has occurred A minor temperature threshold has been exceeded during environmental monitoring Red The module is resetting The switch has just been powered on or the module has been hot inserted during the normal initialization sequence An overtemperature condition has occurred A major temperature threshold has been exceeded during environmental monitoring If the module fails to downl...

Page 114: ...dule current 2 81 A Module power 118 02 W AC input power 147 53 W AC heat dissipation 503 80 BTU hour DC input power 158 63 W DC heat dissipation 541 72 BTU hour Environment Operating temperature Certified for operation 32 to 104 F 0 to 40 C Designed and tested for operation 32 to 130 F 0 to 55 C Humidity RH ambient noncondensing 10 to 90 Operating altitude Certified for operation 0 to 6500 ft 0 t...

Page 115: ...dules QoS Number of egress queues 2 Number of ingress queues 1 Number of thresholds per egress queue 2 Number of thresholds per ingress queue 4 Maximum frame size Up to 8092 bytes per frame both modules Module oversubscription rate N A Supervisor engine support Supported on the following supervisor engines Supervisor Engine 2 Supervisor Engine 32 Supervisor Engine 32 PISA Supervisor Engine 720 Sup...

Page 116: ...ics An overtemperature condition has occurred A minor temperature threshold has been exceeded during environmental monitoring Red The module is resetting The switch has just been powered on or the module has been hot inserted during the normal initialization sequence An overtemperature condition has occurred A major temperature threshold has been exceeded during environmental monitoring If the mod...

Page 117: ...2 39 A Module power 100 38 W AC input power 125 48 W AC heat dissipation 428 50 BTU hour DC input power 134 92 W DC heat dissipation 460 75 BTU hour WS X6348 RJ45V base module PoE daughter card Module current 2 81 A Module power 118 02 W AC input power 147 53 W AC heat dissipation 503 80 BTU hour DC input power 158 63 W DC heat dissipation 541 72 BTU hour Environment Operating temperature Certifie...

Page 118: ...ategory 5 5e and 6 UTP STP cable Buffer size 512 KB per port QoS Number of egress queues 3 Number of ingress queues 2 Number of thresholds per egress queue 2 Number of thresholds per ingress queue 4 Maximum frame size Up to 9216 bytes per frame Module oversubscription rate N A Supervisor engine support Supported on the following supervisor engines Supervisor Engine 2 Supervisor Engine 32 Superviso...

Page 119: ...ring Red The module is resetting The switch has just been powered on or the module has been hot inserted during the normal initialization sequence An overtemperature condition has occurred A major temperature threshold has been exceeded during environmental monitoring If the module fails to download code and configuration information successfully during the initial reset the LED stays red the modu...

Page 120: ...n the chassis Weight 7 65 lb 3 43 kg Power and heat numbers Module current 3 45 A Module power 144 90 W AC input power 181 13 W AC heat dissipation 618 54 BTU hour DC input power 194 76 W DC heat dissipation 665 10 BTU hour Environment Operating temperature Certified for operation 32 to 104 F 0 to 40 C Designed and tested for operation 32 to 130 F 0 to 55 C Humidity RH ambient noncondensing 10 to ...

Page 121: ... X6548V GE TX Base module equipped with a factory installed Cisco prestandard PoE daughter card WS F6K VPWR GE 184596 WS X6548 GE TX STATUS 48 PORT 10 100 1000 BASE T GE SWITCHING MODULE 1 2 3 4 5 6 7 8 9 1 0 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 2 0 2 1 2 2 2 3 2 4 2 5 2 6 2 7 2 8 2 9 3 0 3 1 3 2 3 3 3 4 3 5 3 6 3 7 3 8 3 9 4 0 4 1 4 2 4 3 4 4 4 5 4 6 4 7 4 8 PHONE 1 2 11 12 13 14 23 24 25 26 35 36...

Page 122: ...ughter cards 12 2 17d SXB With Supervisor Engine720 10GE 12 2 33 SXH Queues per port Tx 1p2q2t per 8 ports Rx 1p2t per 8 ports Chassis slot restrictions No chassis or slot restrictions the module can occupy any slot in any Catalyst 6500 or Catalyst 6500 E chassis all variants Bus connection 32 Gbps shared bus all variants Module upgrades available PoE support WS X6548 GE TX Field upgradeable to Ci...

Page 123: ...l initialization sequence An overtemperature condition has occurred A major temperature threshold has been exceeded during environmental monitoring If the module fails to download code and configuration information successfully during the initial reset the LED stays red the module does not come online LINK Green The port is active the link is connected and operational Orange The module or port is ...

Page 124: ...at dissipation 574 49 BTU hour WS X6548 GE 45AF base module PoE daughter card Module current 3 16 A Module power 132 72 W AC input power 165 90 W AC heat dissipation 566 55 BTU hour DC input power 178 39 W DC heat dissipation 609 19 BTU hour WS X6548V GE TX base module PoE daughter card Module current 3 40 A Module power 142 80 W AC input power 178 50 W AC heat dissipation 609 58 BTU hour DC input...

Page 125: ...rt connector type RJ 21 12 ports per connector Cabling distance 328 ft 100 m over Category 5 5e and 6 UTP STP cable Buffer size 1 116 MB per port QoS Number of egress queues 4 Number of ingress queues 2 Number of thresholds per egress queue 1 Number of thresholds per ingress queue 0 Maximum frame size Up to 1518 bytes per frame Module oversubscription rate N A Supervisor engine support Supervisor ...

Page 126: ...module is booting or running diagnostics An overtemperature condition has occurred A minor temperature threshold has been exceeded during environmental monitoring Red The module is resetting The switch has just been powered on or the module has been hot inserted during the normal initialization sequence An overtemperature condition has occurred A major temperature threshold has been exceeded durin...

Page 127: ...ation 519 93 BTU hour DC input power 163 71 W DC heat dissipation 559 07 BTU hour Base module DFC3A daughter card Module current 5 47 A Module power 229 74 W AC input power 287 18 W AC heat dissipation 980 70 BTU hour DC input power 308 79 W DC heat dissipation 1054 52 BTU hour Base module DFC3B daughter card Module current 4 57 A Module power 191 94 W AC input power 239 93 W AC heat dissipation 8...

Page 128: ...0 to 3000 m Table 2 35 WS X6548 RJ 21 Physical and Environmental Specifications continued Item Specification Table 2 36 WS X6548 RJ 45 Features Feature Description Ports per module 48 ports Ports are numbered left to right Top row odd numbered ports 1 47 Bottom row even numbered ports 2 48 1 port group Port ranges per port group 1 48 Port connector type RJ 45 Cabling distance 328 ft 100 m over Cat...

Page 129: ...upervisor Engine 720 12 2 14 SX With Supervisor Engine 720 10GE 12 2 33 SXH Queues per port Tx 1p3q1t Rx 1p1q Chassis slot restrictions No chassis or slot restrictions the module can occupy any slot in any Catalyst 6500 or Catalyst 6500 E chassis Bus connection One 8 Gbps fabric connection and 32 Gbps shared bus Module upgrades available PoE support Not supported Distributed forwarding support Can...

Page 130: ...nmental monitoring If the module fails to download code and configuration information successfully during the initial reset the LED stays red the module does not come online LINK Green The port is active the link is connected and operational Orange The module or port is disabled through the CLI command or the module is initializing1 Flashing orange The port is faulty and has been disabled Off The ...

Page 131: ...card Module current 4 57 A Module power 191 94 W AC input power 239 93 W AC heat dissipation 819 34 BTU hour DC input power 257 98 W DC heat dissipation 881 01 BTU hour Base module DFC3BXL daughter card Module current 4 37 A Module power 183 54 W AC input power 229 43 W AC heat dissipation 783 49 BTU hour DC input power 246 69 W DC heat dissipation 842 46 BTU hour Environment Operating temperature...

Page 132: ...rt connector type RJ 45 Cabling distance 328 ft 100 m over Category 5 5e and 6 UTP STP cable Buffer size 1 3 MB per port QoS Number of egress queues 4 Number of ingress queues 1 2 if DFC3x is present Number of thresholds per egress queue 1 or 2 Number of thresholds per ingress queue 8 Maximum frame size Up to 9216 bytes per frame Module oversubscription rate 1 2 1 Supervisor engine support Supervi...

Page 133: ...nnel 1 Ports 25 48 Fabric channel 2 Ports 1 24 Fabric channel speed 20 Gb sec Module upgrades available PoE support Not supported Distributed forwarding support Ships with a factory installed WS F6700 CFC daughter card The module can be upgraded in the field to support dCEF with the installation of a dCEF daughter card WS F6700 DFC3A WS F6700 DFC3B WS F6700 DFC3BXL WS F6700 DFC3C or the WS F6700 D...

Page 134: ...rature condition has occurred A major temperature threshold has been exceeded during environmental monitoring If the module fails to download code and configuration information successfully during the initial reset the LED stays red the module does not come online LINK Green The port is active the link is connected and operational Orange The module or port is disabled through the CLI command or th...

Page 135: ... Base module WS F6700 CFC daughter card Module current 7 75 A Module power 325 50 W AC input power 406 88 W AC heat dissipation 1389 48 BTU hour DC input power 437 50 W DC heat dissipation 1494 06 BTU hour Base module WS F6700 DFC3A daughter card Module current 10 00 A Module power 420 00 W AC input power 525 00 W AC heat dissipation 1792 88 BTU hour DC input power 564 52 W DC heat dissipation 192...

Page 136: ...at dissipation 1550 84 BTU hour DC input power 488 31 W DC heat dissipation 1667 57 BTU hour Base module WS F6700 DFC3CXL daughter card Module current 9 35 A Module power 392 70 W AC input power 490 88 W AC heat dissipation 1676 34 BTU hour DC input power 527 82 W DC heat dissipation 1802 51 BTU hour Environment Operating temperature Certified for operation 32 to 104 F 0 to 40 C Designed and teste...

Page 137: ...l specifications for the module Figure 2 18 WS X6408A GBIC Ethernet Module Front Panel Table 2 40 WS X6408A GBIC Ethernet Module Features Feature Description Ports per module 8 ports Ports are numbered from 1 left to 8 right 1 port group Port ranges per port group 1 8 Port connector type SC or RJ 45 depending on the GBIC transceiver installed in the module port Cabling distance Depends on the GBIC...

Page 138: ...ervisor Engine 720 12 2 14 SX With Supervisor Engine 720 10GE 12 2 33 SXH Catalyst OS support 6 4 11 Queues per port Tx 1p2q2t Rx 1p1q4t Chassis slot restrictions No chassis or slot restrictions the module can occupy any slot in any Catalyst 6500 or Catalyst 6500 E chassis Bus connection 32 Gbps shared bus Module upgrades available PoE support Not supported Distributed forwarding support Not suppo...

Page 139: ... occurred LINK Green The port is active the link is connected and operational Flashing orange The port failed diagnostics and is disabled Orange The port is disabled Red The module is resetting an overtemperature condition has occurred Note If the module fails to download code and configuration information successfully during the initial reset the LED stays red the module does not come online Off ...

Page 140: ...r DC input power 112 90 W DC heat dissipation 385 56 BTU hour Environment Operating temperature Certified for operation 32 to 104 F 0 to 40 C Designed and tested for operation 32 to 130 F 0 to 55 C Humidity RH ambient noncondensing 10 to 90 Operating altitude Certified for operation 0 to 6500 ft 0 to 2000 m Designed and tested for operation 200 to 10 000 ft 60 to 3000 m Table 2 42 WS X6416 GBIC Fe...

Page 141: ...1 2 E With CWDM GBIC and WS G5483 GBIC transceiver support 12 1 13 E With DWDM GBIC transceiver support 12 1 20 E2 With Supervisor Engine 32 12 2 18 SXF With Supervisor Engine 32 PISA 12 2 18 ZY With Supervisor Engine 720 12 2 14 SX With Supervisor Engine 720 10GE 12 2 33 SXH Queues per port Tx 1p2q2t Rx 1p1q4t Chassis slot restrictions No chassis or slot restrictions the module can occupy any slo...

Page 142: ...odule fails to download code and configuration information successfully during the initial reset the LED stays red the module does not come online Off The port is not active or the link is not connected Table 2 43 WS X6416 GBIC Ethernet Module Physical and Environmental Specifications Item Specification Dimensions H x W x D 1 2 x 14 4 x 16 in 3 0 x 35 6 x 40 6 cm Occupies one slot in the chassis W...

Page 143: ...of GBIC transceiver installed in the module port Cabling distance Depends on the GBIC transceiver installed in the module port Refer to Appendix B for descriptions of the GBIC transceiver types and supported cabling distances Speed 1 Gbps Buffer size 512 KB per port WS X6516 GBIC 1 MB per port WS X6516A GBIC QoS Number of egress queues 3 Number of ingress queues 2 Number of thresholds per egress q...

Page 144: ...y Catalyst 6500 or Catalyst 6500 E chassis Bus connection 32 Gbps shared bus Module upgrades available PoE support Not supported Distributed forwarding support Can be field upgraded with either the WS F6K DFC WS F6K DFC3B or WS F6K DFC3BXL daughter cards Refer to the Catalyst 6500 Series DFC DFC3A DFC3B and DFC3BXL Installation Note for additional information and field upgrade procedures Pluggable...

Page 145: ...LINK Green The port is active the link is connected and operational Flashing orange The port failed diagnostics and is disabled Orange The port is disabled Red The module is resetting an overtemperature condition has occurred Note If the module fails to download code and configuration information successfully during the initial reset the LED stays red the module does not come online Off The port i...

Page 146: ...power 313 43 W AC heat dissipation 1070 35 BTU hour DC input power 337 02 W DC heat dissipation 1150 91 BTU hour Base module DFC3B daughter card WS F6K DFC3B Module current 5 07 A Module power 212 94 W AC input power 266 18 W AC heat dissipation 908 99 BTU hour DC input power 286 21 W DC heat dissipation 977 41 BTU hour Base module DFC3BXL daughter card WS F6K DFC3BXL Module current 4 87 A Module ...

Page 147: ...S F6K DFC3B Module current 5 29 A Module power 222 18 W AC input power 277 73 W AC heat dissipation 948 43 BTU hour DC input power 298 63 W DC heat dissipation 1019 82 BTU hour Base module DFC3BXL daughter card WS F6K DFC3BXL Module current 5 09 A Module power 213 78 W AC input power 267 23 W AC heat dissipation 912 57 BTU hour DC input power 287 34 W DC heat dissipation 981 26 BTU hour Environmen...

Page 148: ...45 copper depending on the SFP transceiver installed Cabling distance Depends on the SFP transceiver installed in the module port Refer to Appendix B for descriptions of the SFP transceiver types and supported cabling distances Buffer size Rx 166 kB per port Tx 1 17 MB per port QoS Number of egress queues 4 Number of ingress queues 1 2 if DFC3x daughter card is present Number of thresholds per egr...

Page 149: ...ield upgrade procedures Pluggable transceivers support SFP transceivers are supported Refer to your software release notes to determine which SFP transceivers are supported See the 1 GB Transceivers section on page B 3 in Appendix B for additional information on the SFP transceivers Digital Optical Monitoring DOM supported Not supported Module front panel LEDs STATUS Green All diagnostics pass the...

Page 150: ...s Base module CFC daughter card WS F6700 CFC Module current 2 98 A Module power 125 16 W AC input power 156 45 W AC heat dissipation 534 28 BTU hour DC input power 168 23 W DC heat dissipation 574 49 BTU hour Base module DFC3A daughter card WS F6700 DFC3A Module current 5 23 A Module power 219 66 W AC input power 274 58 W AC heat dissipation 937 67 BTU hour DC input power 295 24 W DC heat dissipat...

Page 151: ...tion 695 64 BTU hour DC input power 219 03 W DC heat dissipation 748 00 BTU hour Base module DFC3CXL daughter card WS F6700 DFC3CXL Module current 4 58 A Module power 192 36 W AC input power 240 45 W AC heat dissipation 821 14 BTU hour DC input power 258 55 W DC heat dissipation 882 94 BTU hour Environment Operating temperature Certified for operation 32 to 104 F 0 to 40 C Designed and tested for ...

Page 152: ...5 17 19 21 23 2 4 6 8 10 12 14 16 18 20 22 24 25 27 29 31 33 35 37 39 41 43 45 47 26 28 30 32 34 36 38 40 42 44 46 48 Port connector type LC optical or RJ 45 copper depending on the type of SFP transceiver installed in the port Cabling distance Depends on the SFP transceiver installed in the module port Refer to Appendix B for descriptions of the SFP transceiver types and supported cabling distanc...

Page 153: ...hannel 1 Ports 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 Fabric channel 2 Ports 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 Fabric channel speed 20Gb sec Module upgrades available PoE support Not supported Distributed forwarding support Ships with the WS F6700 CFC daughter card factory installed The module can be upgraded in the field to support dCE...

Page 154: ...mperature condition has occurred LINK Green The port is active the link is connected and operational Flashing orange The port failed diagnostics and is disabled Orange The port is disabled Red The module is resetting an overtemperature condition has occurred Note If the module fails to download code and configuration information successfully during the initial reset the LED stays red the module do...

Page 155: ... kg Power requirement at 42 VDC Base module CFC daughter card WS X6700 CFC Module current 6 07 A Module power 254 94 W AC input power 318 68 W AC heat dissipation 1088 28 BTU hour DC input power 342 66 W DC heat dissipation 1170 19 BTU hour Base module DFC3A daughter card WS F6700 DFCA Module current 8 32 A Module power 349 44 W AC input power 436 80 W AC heat dissipation 1491 67 BTU hour DC input...

Page 156: ...dissipation 1249 63 BTU hour DC input power 393 47 W DC heat dissipation 1343 69 BTU hour Base module DFC3CXL daughter card WS F6700 DFC3CXL Module current 7 67 A Module power 322 14 W AC input power 402 68 W AC heat dissipation 1375 14 BTU hour DC input power 432 98 W DC heat dissipation 1478 64 BTU hour Environment Operating temperature Certified for operation 32 to 104 F 0 to 40 C Designed and ...

Page 157: ...he module port Refer to Appendix B for supported GBIC transceiver types and supported cabling distances Buffer size Tx 1 17 MB per port Rx 166 kB per port QoS Number of egress queues 3 Number of ingress queues 2 Number of thresholds per egress queue 2 Number of thresholds per ingress queue 4 Maximum frame size Up to 9216 bytes per frame Module oversubscription rate Approximately 1 1 Supervisor eng...

Page 158: ... does not power up if it is installed in slots 1 8 Fabric connection Dual switch fabric connections Fabric channel 1 Ports 1 8 Fabric channel 2 Ports 9 16 Fabric channel speed 8Gb sec Module upgrades available PoE support Not supported Distributed forwarding support Can be upgraded in the field to support dCEF with the installation of a DFC daughter card WS F6K DFC3A WS F6K DFC3B or the WS F6K DFC...

Page 159: ...e is operational Orange The module is booting or running diagnostics an overtemperature condition has occurred LINK Green The port is active the link is connected and operational Flashing orange The port failed diagnostics and is disabled Orange The port is disabled Red The module is resetting an overtemperature condition has occurred Note If the module fails to download code and configuration inf...

Page 160: ...n 1145 13 BTU hour Base module DFC daughter card WS F6K DFC3B Module current 5 51 A Module power 231 42 W AC input power 289 28 W AC heat dissipation 987 87 BTU hour DC input power 311 05 W DC heat dissipation 1062 23 BTU hour Base module DFC daughter card WS F6K DFC3BXL Module current 6 22 A Module power 261 24 W AC input power 326 55 W AC heat dissipation 1115 17 BTU hour DC input power 351 13 W...

Page 161: ...l specifications Figure 2 24 WS X6704 10GE Ethernet Module Front Panel Table 2 52 WS X6704 10GE Ethernet Module Features Feature Description Ports per module 4 ports Ports are numbered from 1 left to 4 right 4 port groups Port ranges per port group 1 port in each group Port connector type SC or InfiniBand 4X depending on the type of XENPAK transceiver installed in the module Cabling distance Depen...

Page 162: ...on Dual switch fabric connections Fabric channel 1 Ports 3 and 4 Fabric channel 2 Ports 1 and 2 Fabric channel speed 20Gb sec Module upgrades available PoE support Not supported Distributed forwarding support Ships with the WS F6700 CFC daughter card factory installed Can be upgraded in the field to support dCEF with the installation of a DFC daughter card WS F6700 DFC3A WS F6700 DFC3B WS F6700 DF...

Page 163: ...dule is operational Orange The module is booting or running diagnostics an overtemperature condition has occurred LINK Green The port is active the link is connected and operational Flashing orange The port failed diagnostics and is disabled Orange The port is disabled Red The module is resetting an overtemperature condition has occurred Note If the module fails to download code and configuration ...

Page 164: ...at dissipation 1260 39 BTU hour DC input power 396 85 W DC heat dissipation 1355 26 BTU hour WS X6704 10GE base module DFC3A daughter card Module current 9 28 A Module power 389 76 W AC input power 487 20 W AC heat dissipation 1663 79 BTU hour DC input power 523 87 W DC heat dissipation 1789 02 BTU hour WS X6704 10GE base module DFC3B daughter card Module current 8 98 A Module power 377 16 W AC in...

Page 165: ...DFC3CXL daughter card Module current 8 63 A Module power 362 46 W AC input power 453 08 W AC heat dissipation 1547 25 BTU hour DC input power 487 18 W DC heat dissipation 1663 71 BTU hour Environment Operating temperature Certified for operation 32 to 104 F 0 to 40 C Designed and tested for operation 32 to 130 F 0 to 55 C Humidity RH ambient noncondensing 10 to 90 Operating altitude Certified for ...

Page 166: ...orts are numbered from 1 left to 8 right 1 port group Port ranges per port group 1 8 Port connector type SC or CX4 depending on the type of X2 transceiver installed in the module port Cabling distance Depends on the X2 transceiver installed in the module port Refer to Appendix B for supported X2 transceiver types and cabling distances Buffer size 200 MB per port QoS Number of egress queues 8 Numbe...

Page 167: ...D 09 fan trays Fabric connection Dual switch fabric connections Fabric channel 1 Ports 2 3 6 8 Fabric channel 2 Ports 1 4 5 7 Fabric channel speed 20Gb sec Module upgrades available PoE support Not supported Distributed forwarding support WS X6708 10G 3C comes factory equipped with a DFC3C daughter card WS X6708 10G 3CXL comes factory equipped with a DFC3CXL daughter card Pluggable transceivers su...

Page 168: ...nal Orange The module is booting or running diagnostics an overtemperature condition has occurred LINK Green The port is active the link is connected and operational Flashing orange The port failed diagnostics and is disabled Orange The port is disabled Red The module is resetting an overtemperature condition has occurred Note If the module fails to download code and configuration information succ...

Page 169: ...ule power 444 36 W AC input power 555 45 W AC heat dissipation 1896 86 BTU hour DC input power 597 26 W DC heat dissipation 2039 64 BTU hour WS X6708 10G 3CXL base module the DFC3CXL daughter card Module current 11 28 A Module power 473 76 W AC input power 592 20 W AC heat dissipation 2022 36 BTU hour DC input power 636 77 W DC heat dissipation 2174 58 BTU hour Environment Operating temperature Ce...

Page 170: ...net Module Features Feature Description Ports per module 16 ports Ports are numbered left to right Top row odd numbered ports 1 through 15 Bottom row even numbered ports 2 through 16 4 port groups Port ranges per port group 1 4 5 8 9 12 13 16 Port connector type SC or CX4 depending on the type of X2 transceiver installed in the module port Cabling distance Depends on the X2 transceiver installed i...

Page 171: ...series chassis or a Catalyst 6509 NEB A chassis the configuration is NEBS 3 compliant chassis supports operating temperatures up to 55 C When the WS X6716 10G module is installed in a Catalyst 6500 non E series chassis that is equipped with a fan tray 2 and a 2500 W or larger power supply the configuration is not NEBS 3 compliant chassis supports operating temperatures up to 40 C only Support in t...

Page 172: ... X6716 10GE became available provide EMI compliance with the WS X6716 10GE See the 10 GB Transceivers section on page B 8 in Appendix B for additional information Digital Optical Monitoring DOM support Supported on some X2 transceivers Note Refer to your software release notes for specific information on which X2 transceivers support DOM and the software release required for support Module front p...

Page 173: ...ent 10 90 A Module power 457 80 W AC input power 572 25 W AC heat dissipation 1954 23 BTU hour DC input power 615 32 W DC heat dissipation 2101 33 BTU hour WS X6716 10G 3CXL base module the DFC3CXL daughter card 11 6 A Module current 11 60 A Module power 487 20 W AC input power 609 00 W AC heat dissipation 2079 74 BTU hour DC input power 654 84 W DC heat dissipation 2236 27 BTU hour Environment Op...

Page 174: ...ations Figure 2 27 WS X6716 10T 3C and WS X6716 10T 3CXL Ethernet Module Front Panel Note Both of the orderable modules WS X6716 10T 3C and WS X6716 10T 3CXL are identified on the faceplate as WS X6716 10T Table 2 58 WS X6716 10T 3C and WS X6716 10T 3CXL Ethernet Module Features Feature Description Ports per module 4 ports Transparent mode Only port numbers 1 5 9 and 13 are used 16 ports MUX mode ...

Page 175: ...formance mode Tx 1p7q4t per port Rx 8q4t per port Chassis slot restrictions Not supported in the Catalyst 6503 chassis or the Catalyst 6509 NEB chassis Supported only in slots 9 13 in the Catalyst 6513 chassis and does not power up in slots 1 8 When the WS X6716 10G module is installed in a Catalyst 6500 E series chassis or a Catalyst 6509 NEB A chassis the configuration is NEBS 3 compliant chassi...

Page 176: ...gnostics pass the module is operational Orange The module is booting or running diagnostics an overtemperature condition has occurred LINK Green The port is active the link is connected and operational Flashing orange The port failed diagnostics and is disabled Orange The port is disabled Red The module is resetting an overtemperature condition has occurred Note If the module fails to download cod...

Page 177: ...dule power 484 26 W AC input power 605 33 W AC heat dissipation 2067 18 BTU hour DC input power 650 89 W DC heat dissipation 2222 78 BTU hour WS X6716 10T 3CXL base module the DFC3CXL daughter card 12 23 A Module current 12 23 A Module power 513 66 W AC input power 642 08 W AC heat dissipation 2192 69 BTU hour DC input power 690 40 W DC heat dissipation 2357 73 BTU hour Environment Operating tempe...

Page 178: ...2 104 Catalyst 6500 Series Ethernet Modules Installation Guide OL 6265 03 Chapter 2 Ethernet Switching Modules 10 Gigabit Ethernet Modules ...

Page 179: ...terface Cables page 3 22 Verifying the Installation page 3 25 What To Do After Installing Modules and Verifying Connectivity page 3 27 Safety Safety warnings appear throughout this publication in procedures that may harm you if performed incorrectly A warning symbol precedes each warning statement The warnings below are general warnings that are applicable to the entire publication Warning Class 1...

Page 180: ...n describes how to safely install and verify the operation of the Ethernet switching modules Required Tools These tools are required to install switching modules in the chassis Small flat blade screwdriver No 2 Phillips screwdriver Antistatic mat or foam pad to support an unpackaged module Your own ESD prevention equipment or the disposable grounding wrist strap included with the module Installing...

Page 181: ...cing the opening size and making it difficult to install the module Step 6 Remove the module filler plate covering the selected slot by removing the two Phillips pan head screws from the filler plate Note If you must remove an existing module refer to Removing an Ethernet Switching Module section on page 3 10 Step 7 Remove the new module from its shipping packaging and from the antistatic shipping...

Page 182: ...US 4 5 6 SUPERVISOR2 WS X6K SUP2 2GE ST AT US SY ST EM CO NS OL E PW R M GM T RE SE T CONSOLE CONSOLE PORT MODE PCMCIA EJECT PORT 1 PORT 2 Switch Load 100 1 24 PORT 100FX WS X6224 SE LE CT NE XT EMI gasket EMI gasket Insert module between slot guides Ejector lever fully extended ST AT US AC TI VE 4 3 5 5 4 6 6 SWITCH FABRIC MDL WS C6500 SFM STATUS ACTIV E SUPERVISOR2 WS X6K SUP2 2GE ST AT US SY ST...

Page 183: ...ector levers are fully closed when they are flush with the module faceplate See Figure 3 3 Note Failure to fully seat the module in the backplane connector can result in error messages e Tighten the two captive installation screws on the module Note Make sure the ejector levers are fully closed before tightening the captive installation screws 1 2 3 FAN STATUS 4 5 6 SUPERVISOR2 WS X6K SUP2 2GE STA...

Page 184: ... a Horizontal Slot Chassis Chassis with vertical slots a Posi t i on t hem odul ei n t hesl ot SeeFi gur e3 4 M akesur et hatyou al i gn t hesi desoft he swi t chi ng m odul ecar r i erwi t h t hesl otgui deson t het op and bot t om oft hechassi ssl ot b Car ef ul l y sl i det hem odul ei nt o t hesl otunt i lt heEM Igasketal ong t her i ghtedgeoft hem odul e m akescont actwi t h t hem odul eorcov...

Page 185: ...US Ejector lever fully extended SUPERVISOR2 WS X6K SUP2 2GE STA TUS SYS TEM CO NS OLE PW R MG MT RE SET CONSOLE CONSOLE PORT MODE PCMCIA EJECT PORT 1 PORT 2 Switch Load 100 1 SUPERVISOR2 WS X6K SUP2 2GE STA TU S SY STE M CO NS OL E PW R MG MT RE SE T CONSOLE CONSOLE PORT MODE PCMCIA EJECT PORT 1 PORT 2 Switch Load 100 1 SWITCH FABRIC MDL WS C6500 SFM STATUS ACTIV E 4 3 6 SE LE CT NE XT 24 PORT 100...

Page 186: ...W hi l egent l y pr essi ng down on t heej ect orl ever s si m ul t aneousl y cl osebot h l ever st o f ul l y seatt he m odul ei n t hebackpl aneconnect or Theej ect orl ever sar ef ul l y cl osed when t hey ar ef l ush wi t h t he m odul ef acepl at e SeeFi gur e3 6 INPUT OK FAN OK OUTPUT FAIL o INPUT OK FAN OK OUTPUT FAIL o FAN STATUS SE LE CT NE XT 24 PORT 100FX WS X6224 ST AT US AC TIV E SUPE...

Page 187: ... remains orange or turns red the module has not successfully completed the boot process and may have encountered an error For more information about the orange or red STATUS LED states see the LED table for your specific module in Chapter 2 Note You should install switching module filler plates Cisco part number 800 00292 01 in any empty slots to maintain consistent airflow through the switch chas...

Page 188: ...te This step ensures that the space created by the removed module is maintained If the captive installation screws are loose the EMI gaskets on the installed modules will push the modules toward the open slot reducing the opening size and making it difficult to remove the module Step 4 Loosen the two captive screws on the module Make sure that the two captive screws are completely unscrewed from t...

Page 189: ...uire that pluggable transceivers be installed in the module port sockets These transceivers are normally shipped separately from the module and must be installed after the module is installed in the chassis slot This section describes how to install the various kinds of pluggable transceivers in the module Note For additional transceiver installation information see the transceiver installation no...

Page 190: ...attach an ESD grounding strap see the Attaching Your ESD Grounding Strap section on page C 1 for instructions Step 2 Remove the GBIC transceiver from its protective packaging and verify that the GBIC transceiver is the correct type for your network Note If this is an optical GBIC transceiver do not remove optical bore plugs from the GBIC at this time Step 3 Grip the sides of the GBIC transceiver w...

Page 191: ...ching Modules Installing Pluggable Transceivers Figure 3 7 Installing an Optical GBIC Transceiver Plug Shown Removed for Clarity Figure 3 8 Installing a Copper 1000BASE T GBIC Transceiver LINK 51180 Plug GBIC Squeeze in clips and slide GBIC into slot LINK 85745 GBIC Squeeze in clips and slide GBIC into slot ...

Page 192: ...the module port socket Caution We strongly recommend that you do not install or remove the SFP transceiver with fiber optic cables attached to it because of the potential damage to the cables the cable connector or the optical interfaces in the SFP transceiver Disconnect the network interface cable before removing or installing an SFP transceiver SFP transceiver modules can have three types of lat...

Page 193: ...ceiver Wrist strap or other personal grounding device to prevent ESD occurrences Antistatic mat or an antistatic bag to set the unpackaged SFP transceiver on Fiber optic end face cleaning tools and inspection equipment For information on inspecting and cleaning fiber optic interfaces see the document at this URL http www cisco com en US tech tk482 tk607 technologies_white_paper09186a0080254eba sht...

Page 194: ...Grounding Strap section on page C 1 for instructions Step 2 Remove the SFP transceiver from its protective packaging and check the label on the SFP transceiver body to verify that you have the correct model for your network Find the send TX and receive RX markings that identify the top side of the SFP transceiver and position the SFP transceiver in front of the socket opening Note For optical SFP ...

Page 195: ...ot the bale clasp down unlocked position b Pivot the bale clasp down unlocked position c Slide the SFP transceiver completely into the module port socket until the SFP transceiver connector is fully seated d Pivot the bale clasp fully up to lock the SFP transceiver in the socket e Immediately replace the dust plug in the optical bores until you are ready to install the network interface cables Fig...

Page 196: ...into beams or view directly with optical instruments Statement 1051 To install a XENPAK transceiver in a 10 GBASE Ethernet module perform these steps Step 1 Attach an ESD grounding strap to your wrist and to ground Note If you are unsure about the correct way to attach an ESD grounding strap refer to the Attaching Your ESD Grounding Strap section on page C 1 for instructions Step 2 Loosen and remo...

Page 197: ...X2 transceiver port cover Wrist strap or other personal grounding device to prevent ESD occurrences Antistatic mat or an antistatic bag to set the X2 transceiver on Fiber optic end face cleaning tools and inspection equipment For complete information on inspecting and cleaning fiber optic connections see the document at this URL http www cisco com en US tech tk482 tk607 technologies_white_paper091...

Page 198: ...ver as guides for inserting the screwdriver blade Step 3 Remove the X2 transceiver from its protective packaging and check the label on the X2 transceiver body to verify that it is the correct model for your network Note The WS X6708 10G and the WS X6716 10G Ethernet modules have caveats associated with the use of certain types of X2 transceivers Refer to the module descriptions in Chapter 2 for d...

Page 199: ...er EMI gasket is flush against the system module faceplate The X2 transceiver connector is now mated to the socket connector Step 5 Verify that the X2 transceiver latches are fully engaged Secure the X2 transceiver by sliding the transceiver latching sleeve toward the system module faceplate See Figure 3 16 bottom view Caution If the latches are not fully engaged you might accidently disconnect th...

Page 200: ...ust before making any connections Refer to the Tip on inspecting and cleaning fiber optic connections for a pointer to a fiber optic inspection and cleaning document Always grasp the SC or the LC connector housing rather than the fiber optic cable to plug or unplug the fiber optic cable To install the optical interface cables perform the following steps Step 1 Remove the dust plugs from the networ...

Page 201: ... effect of DMD can be overcome by conditioning the launch characteristics of a laser source A practical means of performing this conditioning is to use a device called a mode conditioning patch cord A mode conditioning patch cord is an optical fiber cable assembly that consists of a pair of optical fibers terminated with connector hardware Specifically the mode conditioning patch cord is composed ...

Page 202: ...ch cord maximizes the power budget of multimode 1000BASE LX LH links Note The mode conditioning patch cord is required to comply with IEEE standards The IEEE found that link distances could not be met with certain types of fiber optic cable cores The solution is to launch light from the laser at a precise offset from the center which is accomplished by using the mode conditioning patch cord At the...

Page 203: ...connector on the transceiver Note When connecting to a 1000BASE T compatible switch or repeater use four twisted pair crossover Category 5 cabling Step 2 Insert the other end of the network cable into an RJ 45 connector on a 1000BASE T compatible target device Verifying the Installation This section describes how to verify the installation of a supervisor engine or switching module To verify the i...

Page 204: ...od Module Name Serial Num 1 SAD03392376 15 SAD03366264 3 JAB0343055Y 5 SAD03181291 Mod MAC Address es Hw Fw Sw 1 00 30 96 29 9f 84 to 00 30 96 29 9f 85 1 0 5 2 1 6 1 0 128 ORL 00 30 96 29 9f 86 to 00 30 96 29 9f 87 00 50 3e 8d 64 00 to 00 50 3e 8d 67 ff 15 00 d0 bc ed 6b 2c to 00 d0 bc ed 6b 6b 1 2 12 0 7T XE 12 0 7T XE1 2 07 3 00 90 2b 00 a7 ca to 00 90 2b 00 a7 cb 0 201 4B4LZ0XA 1 1 0 20 5 00 50...

Page 205: ...hing module port perform these tasks For example to ping a host named server1 enter this command Console ping server1 server1 is alive Console What To Do After Installing Modules and Verifying Connectivity After you verify the switching module installation and check connectivity you must configure the module For complete information on configuring the modules see the Catalyst 6500 Series Switch So...

Page 206: ...3 28 Catalyst 6500 Series Ethernet Modules Installation Guide OL 6265 03 Chapter 3 Installing Ethernet Switching Modules What To Do After Installing Modules and Verifying Connectivity ...

Page 207: ... on Catalyst 6500 series modules Table A 1 lists the PoE daughter cards and provides a brief description of their usage Table A 1 PoE Daughter Card Support PoE Daughter Card Description Supported on Ethernet Module Maximum Power per Port Watts WS F6K VPWR Cisco prestandard PoE daughter card for 10 100 and 10 100 1000 Ethernet modules Provides 48 VDC over Category 5 Category 5e or Category 6 UTP ca...

Page 208: ...8X2 AF IEEE 802 3af compliant PoE daughter card for 96 port 10 100 modules Provides 48 VDC over Category 5 Category 5e or Category 6 UTP cable up to 328 feet 100 meters WS X6148X2 RJ 45 WS X6148X2 45AF1 WS X6196 RJ 21 WS X6196 21AF1 15 4 WS F6K 48 AF IEEE 802 3af compliant PoE daughter card for 10 100 and 10 100 1000 Ethernet modules Provides 48 VDC over Category 5 Category 5e or Category 6 UTP ca...

Page 209: ...ed only by the Supervisor Engine 2 WS X6516 GBIC WS X6816 GBIC WS X6516 GE TX 128 MB 2 10 A at 42 VDC WS F6K DFC3A Distributed Forwarding Card DFC for use on CEF256 based modules WS X65xx and WS X6816 GBIC Ethernet modules This daughter card is supported only by the Supervisor Engine 720 WS X6516 GBIC WS X6816 GBIC 512 MB Memory is located on base module 2 57 A at 42 VDC WS F6K DFC3B Distributed F...

Page 210: ...S X6708 10G 3C and the WS X6716 10G 3C Ethernet modules It is an option for all other CEF720 linecards beginning with Cisco IOS Release 12 2 33 SXH This daughter card is supported only by the Supervisor Engine 720 WS X6704 10GE WS X6708 10G 3C WS X6716 10G 3C WS X6716 10T 3C WS X6724 SFP WS X6748 SFP WS X6748 GE TX 512 MB2 1 GB 1 GB 1 GB 512 MB2 512 MB2 512 MB2 1 65 A at 42 VDC WS F6700 DFC3CXL Th...

Page 211: ...y WS SUP720 3BXL PFC3A functionality PFC3B functionality PFC3BXL functionality VS S720 10G 3C PFC3A functionality PFC3B functionality PFC3B functionality VS S720 10G 3CXL PFC3A functionality PFC3B functionality PFC3BXL functionality Table A 4 WS F6700 DFC Daughter Card Functionality Levels Supervisor Engine 720 Model WS F6700 DFC3A WS F6700 DFC3B WS F6700 DFC3BXL WS F6700 DFC3C WS F6700 DFC3CXL WS...

Page 212: ...A 6 Catalyst 6500 Series Ethernet Modules Installation Guide OL 6265 03 Appendix A Ethernet Module Daughter Cards Centralized and Distributed Forwarding Daughter Cards ...

Page 213: ... B 8 WDM Transceivers page B 15 100 MB Transceivers 100 MB Small Form Factor Pluggable SFP transceivers are currently the only 100 MB transceivers that are supported on a Catalyst 6500 series Ethernet switching module They are supported only on the WS X6148 FE SFP Ethernet module The 100 MB SFP transceiver module is shown in Figure B 1 Table B 1 lists the types of 100 MB SFP transceivers and their...

Page 214: ...ual LC 1310 MMF 50 62 5 1 24 miles 2 km GLC FE 100LX 100BASE LX10 SFP for 100 Mb Fast Ethernet ports Dual LC 1310 SMF G 6523 3 ITU T G 652 SMF as specified by the IEEE 802 3z standard 6 21 miles 10 km GLC FE 100BX D 100BASE FX SFP for 100 Mb Fast Ethernet ports Single LC 1550 receive 1310 transmit Single strand SMF G 6523 6 21 miles 10 km GLC FE 100BX U 100BASE FX SFP for 100 Mb Fast Ethernet port...

Page 215: ...e B 3 100 MB SFP Transceiver Physical and Environmental Specifications Item Specification Dimensions H x W x D 0 04 x 0 53 x 2 22 in 8 5 x 13 4 x 56 5 mm Operating temperature Storage temperature 32 to 122 F 0 to 50 C 40 to 185 F 40 to 85 C Table B 4 1 GB Transceiver Types 1 GB Transceiver Type Supported on these Modules1 1 Not all GBIC transceiver types or SFP transceiver types may be supported o...

Page 216: ...GBIC Transceiver WS G5483 Figure B 3 1000BASE X GBIC Transceiver Modules WS G5484 WS G5486 and WS G5487 RJ 45 connector Plastic tab 49959 Table B 5 GBIC Transceiver Module Cabling Specifications GBIC Transceiver Model and Product Number Interface Connector Nominal Wavelength nm Network Cable Type Fiber Core Size1 micron Modal Bandwidth MHz km Cable Distance2 1000BASE T WS G5483 RJ 45 328 ft 100 m ...

Page 217: ...gths of MMF and reduces differential mode delay for long lengths of MMF 5 ITU T G 652 SMF as specified by the IEEE 802 3z standard 6 Use with SMF only 7 Dispersion shifted single mode fiber optic cable 8 The minimum link distance for ZX GBICs is 6 2 miles 10 km when an 8 dB attenuator is installed at each end of the link Without attenuators the minimum link distance is 24 9 miles 40 km Table B 5 G...

Page 218: ...rs Figure B 4 1000BASE T SFP Transceiver GLC T Figure B 5 1000BASE X SFP Transceivers Table B 7 1 GB GBIC Transceiver Physical and Environmental Specifications Item Specification Dimensions H x W x D 0 75 x 1 54 x 3 50 in 19 0 x 39 1 x 88 9 mm Operating temperature Storage temperature 32 to 122 F 0 to 50 C 40 to 185 F 40 to 85 C 1 RJ 45 connector 3 Bale clasp shown in the open unlocked position 2 ...

Page 219: ...ting in an elevated bit error rate BER When using the LX LH SFP transceiver with 62 5 micron diameter MMF you must also install a mode conditioning patch cord between the SFP transceiver and the MMF cable on both the sending and receiving ends of the link The mode conditioning patch cord is required for link distances greater than 984 ft 300 m 62 5 50 0 50 0 G 6523 3 ITU T G 652 SMF as specified b...

Page 220: ...transceivers and X2 transceivers differ in form factor they are not interchangeable Table B 11 lists both 10 GB transceiver types and the modules that support them Table B 10 1 GB SFP Transceiver Physical and Environmental Specifications Item Specification Dimensions H x W x D 0 04 x 0 53 x 2 22 in 8 5 x 13 4 x 56 5 mm Operating temperature Storage temperature 32 to 122 F 0 to 50 C 40 to 185 F 40 ...

Page 221: ... optical and the cabling distance specifications for the XENPAK transceivers Note The dual SC connector on the X2 transceivers support network interface cables with either Physical Contact PC or Ultra Physical Contact UPC polished face types The connectors do not support network interface cables with an Angle Polished Connector APC polished face type Figure B 6 10 Gigabit XENPACK Transceiver 1 Cap...

Page 222: ...t the transmitter output should be coupled through a mode conditioning patch cord Cisco offers two mode conditioning patch cords CAB GELX 625 mode conditioning patch cable 62 5 microns dual SC connectors and CAB MCP50 SC mode conditioning patch cable 50 microns dual SC connectors XENPAK 10GB LR XENPAK 10GB LR SC duplex 1310 nm SMF G 6524 4 ITU T G 652 SMF as specified by the IEEE 802 3z standard E...

Page 223: ... minimum XENPAK 10GB LX4 0 5 per lane maximum 6 75 per lane minimum 0 5 per lane maximum 14 25 per lane minimum XENPAK 10GB LR XENPAK 10GB LR 0 5 maximum 8 2 minimum 0 5 maximum 14 4 minimum XENPAK 10GB LRM 0 5 maximum 6 5 minimum 0 5 maximum 8 4 minimum in average 6 4 minimum in Optical Modulation Amplitude OMA 2 2 Both the average and the OMA specifications must be met simultaneously XENPAK 10GB...

Page 224: ... shifted fiber DSF X2 10GB LR transceivers labeled with a serial number that ends in 02 do not provide EMI compliance with the WS X6716 10GE module See Figure B 7 for the serial number location X2 10GB LRM 10GBASE LRM for FDDI grade multimode fiber MMF The X2 10GB LRM is not supported by the show idprom command X2 10GB LX4 10GBASE LX4 serial 1310 nm multimode fiber MMF X2 10GB LX4 transceivers tha...

Page 225: ...ied Table B 15 lists the cabling specifications for the X2 transceivers Figure B 8 10 GB X2 Transceiver 1 Transmit optical bore 6 Module connector 2 Receive optical bore 7 Latch extended 3 Latching sleeve retracted 8 Latching sleeve extended 4 EMI gasket 9 Latch retracted 5 Transceiver heat sink 5 6 120754 4 3 8 1 2 7 9 Latching sleeve retracted latch extended Latching sleeve extended latch retrac...

Page 226: ...87 4 ft 240 m 984 3 ft 300 m 3 The Cisco X2 10GB LX4 transceiver supports link lengths of 300 meters on standard Fiber Distributed Data Interface FDDI grade multimode fiber MMF To ensure that specifications are met the transmitter output should be coupled through a mode conditioning patch cord Cisco offers two mode conditioning patch cords CAB GELX 625 mode conditioning patch cable 62 5 microns du...

Page 227: ...er dBm X2 10GB LRM 0 5 max 6 5 min 0 5 max 8 4 min In average 1 6 4 min in Optical Modulation Amplitude OMA 1 Both the average and the OMA specifications must be met simultaneously X2 10GB SR 1 2 max 2 7 3 min 2 The launch power shall be the lesser of the class 1 safety limit or the maximum receive power Class 1 laser requirements are defined by IEC 60825 2001 1 0 max 9 9 min X2 10GB LR 0 5 max 8 ...

Page 228: ...vers are used as part of a DWDM optical network to provide high capacity bandwidth across an optical fiber network There are 32 fixed wavelength DWDM GBICs that support the International Telecommunications Union ITU 100 GHz wavelength grid The DWDM GBIC transceivers have a duplex SC connector WS X6408A GBIC WS X6416 GBIC WS X6516 GBIC WS X6516A GBIC WS X6816 GBIC Figure B 10 Table B 20 R O WDM GBI...

Page 229: ... fiber network There are 32 fixed wavelength DWDM XENPAK transceivers that support the International Telecommunications Union ITU 100 GHz wavelength grid The DWDM XENPAK transceivers have a duplex SC connector WS X6704 10GE Figure B 12 Table B 22 R O WDM XENPAK The R O WDM XENPAK receiver WDM XENPAK REC operates as a pluggable receiver on any unidirectional link in a CWDM or DWDM transport network...

Page 230: ...Transceivers Wavelengths Model Number Color Code CWDM GBIC Wavelength CWDM GBIC 1470 Gray 1470 nm laser single mode CWDM GBIC 1490 Violet 1490 nm laser single mode CWDM GBIC 1510 Blue 1510 nm laser single mode CWDM GBIC 1530 Green 1530 nm laser single mode CWDM GBIC 1550 Yellow 1550 nm laser single mode CWDM GBIC 1570 Orange 1570 nm laser single mode CWDM GBIC 1590 Red 1590 nm laser single mode CW...

Page 231: ...000BASE DWDM 1550 12 nm GBIC 34 DWDM GBIC 48 51 1000BASE DWDM 1548 51 nm GBIC 36 DWDM GBIC 47 72 1000BASE DWDM 1547 72 nm GBIC 37 DWDM GBIC 46 92 1000BASE DWDM 1546 92 nm GBIC 38 DWDM GBIC 46 12 1000BASE DWDM 1546 12 nm GBIC 39 DWDM GBIC 44 53 1000BASE DWDM 1544 53 nm GBIC 41 DWDM GBIC 43 73 1000BASE DWDM 1543 73 nm GBIC 42 DWDM GBIC 42 94 1000BASE DWDM 1542 94 nm GBIC 43 DWDM GBIC 42 14 1000BASE ...

Page 232: ...ngle mode CWDM SFP 1610 Brown 1610 nm laser single mode Table B 22 DWDM XENPAK Transceiver Module Product Numbers and ITU Channel Numbers DWDM XENPAK Product Number Description ITU Channel DWDM XENPAK 60 61 1000BASE DWDM 1560 61 nm XENPAK 21 DWDM XENPAK 59 79 1000BASE DWDM 1559 79 nm XENPAK 22 DWDM XENPAK 58 98 1000BASE DWDM 1558 98 nm XENPAK 23 DWDM XENPAK 58 17 1000BASE DWDM 1558 17 nm XENPAK 24...

Page 233: ... 46 12 1000BASE DWDM 1546 12 nm XENPAK 39 DWDM XENPAK 44 53 1000BASE DWDM 1544 53 nm XENPAK 41 DWDM XENPAK 43 73 1000BASE DWDM 1543 73 nm XENPAK 42 DWDM XENPAK 42 94 1000BASE DWDM 1542 94 nm XENPAK 43 DWDM XENPAK 42 14 1000BASE DWDM 1542 14 nm XENPAK 44 DWDM XENPAK 40 56 1000BASE DWDM 1540 56 nm XENPAK 46 DWDM XENPAK 39 77 1000BASE DWDM 1539 77 nm XENPAK 47 DWDM XENPAK 39 98 1000BASE DWDM 1539 98 ...

Page 234: ...000BASE DWDM 1532 68 nm XENPAK 56 DWDM XENPAK 31 90 1000BASE DWDM 1531 90 nm XENPAK 57 DWDM XENPAK 31 12 1000BASE DWDM 1531 12 nm XENPAK 58 DWDM XENPAK 30 33 1000BASE DWDM 1530 33 nm XENPAK 59 Table B 22 DWDM XENPAK Transceiver Module Product Numbers and ITU Channel Numbers continued DWDM XENPAK Product Number Description ITU Channel 1 Captive installation screw 2 Dustplug 3 Transmit optical bore ...

Page 235: ...th a banana plug connector identified by the ground symbol next to the connector somewhere on the front panel If you have an older Catalyst 6500 series chassis equipped with a plastic banana plug connector we recommend that you use either the supplied ESD grounding wrist strap with a metal clip or an ESD grounding wrist strap equipped with an alligator clip If you have a newer Catalyst 6500 series...

Page 236: ...or alligator clip on the ESD wrist strap and momentarily touch the clip to a bare metal spot unpainted surface on the rack We recommend that you touch the clip to an unpainted rack rail so that any built up static charge is then safely dissipated to the entire rack Step 3 Attach either the spring clip or the alligator clip to the ground lug screw as follows See Figure C 1 a If you are using the ES...

Page 237: ... of the antistatic strap The measurement should be between 1 and 10 megohm Mohm SUPERVISOR2 WS X6K SUP2 2GE STATUS SYSTEM CO NSO LE PW R M G M T RESET CONSOLE CONSOLE PORT MODE PCMCIA EJECT PORT 1 PORT 2 Switch Load 100 1 LI NK LI NK OSM 4OC12 POS SI 4 PORT OC 12 POS SM IR STATUS 1 1 2 2 3 3 4 4 RESET LIN K LIN K LIN K LIN K CARRIE R ALARM CARRIE R ALARM CARRIE R ALARM CARRIE R ALARM ACTIV E TX RX...

Page 238: ...C 4 Catalyst 6500 Series Ethernet Modules Installation Guide OL 6265 03 Appendix C ESD Precautions Attaching Your ESD Grounding Strap ...

Page 239: ...C 2 92 to 2 95 WS X6708 10G 3CXL 2 92 to 2 95 WS X6716 10G 3C 2 96 to 2 99 WS X6716 10G 3CXL 2 96 to 2 99 WS X6716 10T 3C 2 100 to 2 103 WS X6716 10T 3CXL 2 100 to 2 103 10 GB transceivers B 8 to B 15 X2 transceivers B 8 to B 15 modules supported on B 8 optical transmit and receive specifications B 15 physical and environmental specifications table B 15 XENPAK transceivers B 8 to B 11 modules supp...

Page 240: ...tches airflow 1 14 altitude operating 1 14 chassis dimensions 1 14 environmental specifications 1 14 fan trays supported 1 14 features table 1 11 form factor front view figure 1 11 form factor rear view figure 1 11 humidity operating 1 14 physical characteristics 1 14 port densities supported 1 13 slot numbering 1 12 specifications table 1 11 supervisor engines supported 1 12 temperature operating...

Page 241: ... 44 weight 1 44 Catalyst 6509 NEB switches airflow 1 39 altitude operating 1 39 chassis dimensions 1 39 environmental specifications 1 39 fan trays supported 1 39 features table 1 35 form factor figure 1 35 humidity operating 1 39 physical characteristics 1 39 port densities supported 1 38 slot numbering 1 36 specifications 1 35 supervisor engines supported 1 37 temperature operating 1 39 weight 1...

Page 242: ...1 52 slot numbering 1 50 specifications table 1 49 supervisor engines supported 1 51 temperature operating 1 53 weight 1 53 chassis Catalyst 6509 E switches 1 34 commands show module 3 26 show port 3 26 connectivity checking 3 27 conventions documentation 1 vi CWDM GBIC transceivers description B 16 modules supported on B 16 physical form figure B 18 wavelength table B 18 CWDM SFP transceivers des...

Page 243: ... WS X6148 FE SFP 2 4 WS X6148 GE TX 2 15 WS X6148 RJ21 2 19 WS X6148 RJ 45 2 24 WS X6148X2 RJ 45 2 30 WS X6196 RJ 21 2 34 WS X6324 100FX MM 2 7 WS X6324 100FX SM 2 7 WS X6348 RJ21V 2 38 WS X6348 RJ45 2 41 WS X6408A GBIC 2 63 WS X6416 GBIC 2 66 WS X6516A GBIC 2 69 WS X6516 GBIC 2 69 WS X6516 GE TX 2 44 WS X6524 100FX MM 2 10 WS X6548 GE TX 2 47 WS X6548 RJ 21 2 51 WS X6548 RJ 45 2 54 WS X6704 10GE ...

Page 244: ...48 RJ 21 2 53 WS X6548 RJ 45 2 56 WS X6704 10GE 2 90 WS X6708 10G 3C 2 95 WS X6708 10G 3CXL 2 95 2 99 WS X6716 10G 3C 2 99 WS X6716 10T 3C 2 103 WS X6716 10T 3CXL 2 103 WS X6724 SFP 2 76 WS X6748 GE TX 2 61 WS X6748 SFP 2 81 WS X6816 GBIC 2 86 physical characteristics Catalyst 6503 E switches 1 10 Catalyst 6503 switches 1 6 Catalyst 6504 E switches 1 14 Catalyst 6506 E switches 1 24 Catalyst 6506 ...

Page 245: ...yst 6509 switches 1 25 Catalyst 6509 V E switches 1 45 Catalyst 6513 E switches 1 54 Catalyst 6513 switches 1 49 splitter panel WS F6K 48X2 SPLTR splitter panel See WS X6148X2 RJ 45 T tools required for installation 3 2 transceivers 1 GB transceivers B 3 to B 8 Also see specific transceiver type V verifying installation 3 26 W warnings conventions viii translations viii warning definition viii WDM...

Page 246: ...2 4 transceivers supported 2 3 upgrades available 2 3 weight 2 4 WS X6148 21AF See WS X6148 RJ21 WS X6148 45AF See WS X6148 RJ 45 WS X6148A 45AF See WS X6148 RJ 45 WS X6148A GE 45AF See WS X6148A GE TX WS X6148A GE TX 2 14 to 2 19 altitude operating 2 19 dimensions 2 17 features table 2 15 front panel figure 2 14 humidity operating 2 19 LEDs 2 17 network connector type 2 15 physical and environmen...

Page 247: ...ransceivers supported 2 21 upgrades supported 2 21 weight 2 22 WS X6148 RJ21V See WS X6148 RJ21 WS X6148 RJ 45 2 23 to 2 28 altitude operating 2 28 dimensions 2 27 features table 2 24 front panel figure 2 23 humidity operating 2 28 LEDs 2 26 module variants 2 23 network connector type 2 24 physical and environmental specifications table 2 27 ports 2 24 power requirement 2 27 2 28 restrictions slot...

Page 248: ... 9 ports 2 7 power requirement 2 9 restrictions slot and chassis 2 8 supervisor engine support 2 7 temperature operating 2 9 transceivers supported 2 8 upgrades available 2 8 weight 2 9 WS X6324 100FX SM 2 7 to 2 9 altitiude operating 2 9 dimensions 2 9 features table 2 7 front panel figure 2 7 humidity operating 2 9 LEDs 2 8 network connector type 2 7 physical and environmental specifications tab...

Page 249: ... operating 2 68 dimensions 2 68 features table 2 66 front panel figure 2 66 humidity operating 2 68 LEDs 2 68 network connector type 2 66 physical and environmental specifications table 2 68 ports 2 66 power requirement 2 68 supervisor engine support 2 67 temperature operating 2 68 transceivers supported 2 67 upgrades available 2 67 weight 2 68 WS X6516A GBIC 2 69 to 2 73 altitude operating 2 73 d...

Page 250: ...11 supervisor engine support 2 10 temperature operating 2 13 transceivers supported 2 11 upgrades available 2 11 weight 2 12 WS X6548 GE 45AF See WS X6548 GE TX WS X6548 GE TX 2 47 to 2 50 altitude operating 2 50 dimensions 2 50 environmental specifications table 2 50 features table 2 47 front panel figure 2 47 humidity operating 2 50 LEDs 2 49 network connector type 2 47 ports 2 47 power requirem...

Page 251: ...ng 2 95 dimensions 2 95 features table 2 92 front panel figure table 2 92 humidity operating 2 95 LEDs 2 94 network connector type 2 92 physical and environmental specifications table 2 95 ports 2 92 power requirement 2 95 restrictions slot and chassis 2 93 supervisor engines supported 2 92 temperature operating 2 95 transceivers supported 2 93 upgrades available 2 93 weight 2 95 WS X6708 10G 3CXL...

Page 252: ... slot and chassis 2 101 supervisor engines supported 2 101 temperature operating 2 103 transceivers supported 2 102 upgrades available 2 102 weight 2 103 WS X6716 10T 3CXL 2 100 to 2 103 altitude operating 2 103 dimensions 2 103 features table 2 100 front panel figure 2 100 humidity operating 2 103 LEDs 2 102 network connector type 2 100 physical and environmental specifications table 2 103 ports ...

Page 253: ... 2 78 temperature operating 2 82 transceivers supported 2 79 upgrades available 2 79 weight 2 81 WS X6816 GBIC 2 83 to 2 86 altitude operating 2 86 dimensions 2 86 features table 2 83 front panel figure 2 83 humidity operating 2 86 LEDs 2 85 network connector type 2 83 physical and environmental specifications table 2 86 ports 2 83 power requirement 2 86 restrictions slot and chassis 2 84 supervis...

Page 254: ...Index IN 16 Catalyst 6500 Series Ethernet Modules Installation Guide OL 6265 03 ...