41
OL-32830-01 Command Line Interface Reference Guide
797
Remote Network Monitoring (RMON)
Commands
1
41.1
rmon alarm
To configure alarm conditions, use the rmon alarm Global Configuration
modecommand. To remove an alarm, use the no form of this command.
Syntax
rmon alarm
index mib-object-id interval rising-threshold falling-threshold
rising-event falling-event [type {absolute | delta}] [startup {rising | rising-falling |
falling}] [owner name]
no rmon alarm
index
Parameters
•
index—Specifies the alarm index. (Range: 1–65535)
•
mib-object-id—Specifies the object identifier of the variable to be sampled.
(Valid OID)
•
interval—Specifies the interval in seconds during which the data is
sampled and compared with rising and falling thresholds. (Range:
1–2147483647)
•
rising-threshold—Specifies the rising threshold value. (Range:
0–2147483647)
•
falling-threshold—Specifies the falling threshold value. (Range:
0–2147483647)
•
rising-event—Specifies the index of the event triggered when a rising
threshold is crossed. (Range: 0–65535)
•
falling-event—Specifies the index of the event triggered when a falling
threshold is crossed. (Range: 0–65535)
Summary of Contents for 300 Series
Page 2: ......