background image

INSTRUCTION MANUAL

Power quality analyser

VLOG-10

(M091B01-03-18A)

Summary of Contents for VLOG-10

Page 1: ...INSTRUCTION MANUAL Power quality analyser VLOG 10 M091B01 03 18A...

Page 2: ...2 VLOG 10 Instruction Manual...

Page 3: ...ly prior to connecting the unit Follow all installation and maintenance instructions throughout the unit s working life Pay special attention to the installation stan dards of the National Electrical...

Page 4: ...1 1 VOLTAGE ANALYSIS 11 4 1 2 FREQUENCY ANALYSIS 12 4 2 MEASUREMENT PARAMETERS 12 4 2 1 LOGS 13 4 2 2 EVENTS 13 4 3 RESET BUTTON 13 4 4 LED INDICATORS 14 4 4 1 MAINS ANALYSIS 14 4 4 2 UPLOADING DATA...

Page 5: ...g Date Revision Description 06 18 M091B01 03 18A Initial Version Note The images of the devices are for illustrative purposes only and may differ from the orig inal device SYMBOLS Table 2 Symbols Symb...

Page 6: ...mmediately contact the carrier and or CIRCUTOR s after sales service if you detect any problem in the device upon reception 2 PRODUCT DESCRIPTION The VLOG 10 power quality analyser is a programmable m...

Page 7: ...o avoid accidents personal injury and damage to installations Limit the operation of the device to measuring the specified current or voltage values The manufacturer of the device shall not be held re...

Page 8: ...s at the same time There is a risk of electrocution and or destruction of the connected devices VLOG 10 and PC Check the following points before connecting the device Power supply and voltage measurem...

Page 9: ...Remove the seal from the internal battery To do this pull the seal in the direction of the arrow as shown in Figure 3 USB N L POWER SUPPLY POWER SAMPLING EVENT LOG RESET Precinto Seal Figure 3 Seal fr...

Page 10: ...k on Yes and configure the device see 5 3 CONFIGURATION Figure 4 Information screen when a new device is connected The device is now prepared to operate autonomously after it has been connected to the...

Page 11: ...0 or 60 Hz respectively This results in the device performing 200 voltage measurements per period irrespective of the mains frequency The mains voltage RMS is calculated using the following mathematic...

Page 12: ...1 2 FREQUENCY ANALYSIS The frequency is calculated by measuring the time that has elapsed between five successive zero crossings changes from positive to negative voltages or vice versa of the input...

Page 13: ...logged in the memory when the voltage level is above the thresh old defined in the device s pre configuration Voltage interrupt Event logged in the memory when the voltage level is below 85 V Frequen...

Page 14: ...alysis mode the steady SAMPLING LED indicates that the device is analysing the mains and storing Logs according to the set parameters Meanwhile the EVENT LED indicates that some form of incident has o...

Page 15: ...no preconfigured time x1 Battery drained 1 7 V x2 RAM full if memory configured to non circular x3 Error starting RAM hardware x4 Error starting FLASH hardware x5 Note In the EVENT column the number...

Page 16: ...7 V Battery drained impeding the operation of the device The device indicates this status through the alternate flashing of the SAM PLING and EVENT LEDs Connect the device to the VLOG 10 Software and...

Page 17: ...ttp docs circutor com docs VLOG Application http docs circutor com docs VLOG 10 1 5 zip When the driver and software have been installed the screen in Figure 8 is displayed when running the configurat...

Page 18: ...h the device is connected When the connection port has been properly configured the application automatically recognis es the device displaying its data on the screen In this state the SAMPLING LED fl...

Page 19: ...Indicates the voltage of the battery inside the device 5 2 2 PARTIAL ENERGY METERS Figure 12 Partial energy meters These parameters indicate the number of mains incidents detected since the last rese...

Page 20: ...since the last reset 5 2 3 TOTAL ENERGY METERS Figure 13 Total energy meters The parameters in this section are the same as for the partial energy meters but the values cannot be reset So it stores a...

Page 21: ...e 87 V Maximum configuration value 265 V Umbral de hueco de tensi n Voltage gap threshold Voltage level below which a Voltage gap event is generated Minimum configuration value 85 V Maximum configurat...

Page 22: ...tion If you choose to delete the memory of the device all of the partial energy meters and all events and logs recorded by the VLOG 10 will be deleted When you have finished configuring the device cli...

Page 23: ...upt 16 09 2015 10 16 55 Device start up 16 09 2015 10 17 23 Voltage gap 16 09 2015 10 29 00 Voltage interrupt Figure 19 Example of an events_ddmmaaaa csv file 2 logs_ddmmaaaa csv The file containing t...

Page 24: ...icator LEDs Connectivity USB Internal battery Type Li MnO2 Lithium Manganese Dioxide Voltage 3 V Capacity 220 mAh Autonomy 10 years Environmental features Operating temperature 10 C 55 C Storage tempe...

Page 25: ...25 Instruction Manual VLOG 10 116 26 43 Figure 21 VLOG 10 dimensions...

Page 26: ...le failure improper installation or improper usage of the unit Consequently this guarantee does not apply to failures occurring in the following cases Overvoltages and or electrical disturbances in th...

Page 27: ...27 Instruction Manual VLOG 10 9 CE CERTIFICATE...

Page 28: ...28 VLOG 10 Instruction Manual...

Page 29: ...29 Instruction Manual VLOG 10...

Page 30: ...CIRCUTOR SA Vial Sant Jordi s n 08232 Viladecavalls Barcelona Tel 34 93 745 29 00 Fax 34 93 745 29 14 www circutor es central circutor com...