LOGIX MAPPING
Page 28 of 36
HardwareMACaddress
SINT[6]
Ethernet MAC address
Analog Input - Voltage (0-10V)
REAL
Analog Input in Volts (when DIP SW3.2 =0)
Analog Input - Current (0-20mA)
REAL
Analog Input in mA (when DIP SW3.2 =1)
CurrentDO0
REAL
Current consumption of Sensor Healthy LED
(mA)
CurrentDO1
REAL
Current consumption of Trip/Fault LED (mA)
CurrentDO2
REAL
Current consumption of DO2 (Emitter Gate)
(mA)
CurrentDO0On
REAL
Last On Current consumption of Sensor Healthy
LED (mA)
CurrentDO1On
REAL
Last On Current consumption of Trip/Fault LED
(mA)
CurrentDO2On
REAL
Last On Current consumption of DO2 (Emitter
Gate) (mA)
Beam Unhealthy Counter
DINT
Beam Unhealthy Fault Counter
Trip Counter
DINT
Trip Counter
Fault Counter
DINT
Fault Current Fault Counter
Reset Counter
DINT
Reset Button Counter
Beam Self-Test Counter
DINT
Beam Self-Test Counter
ResetStatsCommand Readback
DINT
Echo of Output Assembly
Table 4.1
–
Pre-start Warning Logix 5000 input assembly parameters
4.1.1. O
UTPUT
A
SSEMBLY
The following parameters are used in the Output assembly of the Pre-start Warning
module.
Output
ResetStatsCommand
SINT
Transition from 0-1 triggers reset stats
Table 4.2
–
Pre-start Warning Logix 5000 Output Assembly Parameters