20
Wallbox eNext Series Installation Manual
THREE-PHASE Charge Point
•
Connect to the
400VAC
.
•
If the Power Supply is Single-Phase,
connect L1 and N.
•
If the Power Supply is Single- Phase
but the charger is able to work with
three phase, connect only L1 and N
with a nominal voltage of 230V, it will
work as a single-phase charger with
any issue
2 B. W I R I N G D I AG R A M E X T E R N A L E L E C T R I C P R OT E C T I O N S
W I T H O U T F E E D BAC K I N CA S E O F W E L D E D C O N TAC T O R D C L E A K AG E
L
N
P
E
Protections
L1
L2
L3
N
P
E
Protections
SINGLE-PHASE Charge Point
•
Connect to the
230VAC
.
In case of
welded contact or DC leakage detection
the external
protections will trip, powering off the whole charger and the control
board will not be able to report the active error. The content of chapter
5 sections G and H are invalid when using this wiring scheme.