This manual provides commissioning information about Wallbox eNext series, which 
has been designed and tested to allow electric vehicle charging according to IEC 
61851-1:2017.

This document has different sections such as step-by-step installation procedure and 
technical data.

ELECTRICAL RISK

Necessary precautions shall be taken to prevent any electrical risk 
while the operations are carried out within the unit.

Unit must be disconnected from any power source during 
commissioning.

ATTENTION!

Indicates that damage to property can occur if appropriate 
precautions are not taken.

(*) These compliances only apply to eNext Elite Model

So, hello!

THE FOLLOWING SYMBOLS ARE USED FOR IMPORTANT 

SAFETY INFORMATION IN THIS DOCUMENT

• 

Complies with IEC 61851, Electric vehicle conductive charging 
system (IEC 61851-1:2017 and IEC 61851-21-2:2018).

• 

Complies with IEC 62196, Plugs, socket-outlets, vehicle 
couplers and vehicle inlets (IEC 62196-1  and IEC 62196-2). 

• 

Directives: 2014/35/UE, LVD;2014/30/UE, EMC.

• 

RFID complies with ISO/IEC 14443A/B *

• 

Modem 4G complies with IEC 60950-1 and CE/RED *

Summary of Contents for Wallbox eNext Series

Page 1: ...Installation Manual Wallbox eNext Series ...

Page 2: ...Wallbox eNext Series Installation Manual ...

Page 3: ... this manual can be reproduced copied translated or transmitted in any form or by any means without the prior written permission of the original manufacturer Information provided in this manual is intended to be accurate and reliable However the original manufacturer assumes no responsibility for its use or for any infringements upon the rights of third parties at hat may result from its use All o...

Page 4: ...Wallbox eNext Series Installation Manual ...

Page 5: ...ation 12 A Requirements 13 B Opening 14 C Positioning 15 D Fixing 16 E Wiring 17 F Home BeON 21 G DC current leakage detector 22 H Welded contactor detector 22 I Remote control function 23 J Closing 24 6 Technical data 26 7 Need help 29 8 Notes Here s your guide to install eNext 31 ...

Page 6: ...02 Wallbox eNext Series Installation Manual 1 ...

Page 7: ...isconnected from any power source during commissioning ATTENTION Indicates that damage to property can occur if appropriate precautions are not taken These compliances only apply to eNext Elite Model So hello THE FOLLOWING SYMBOLS ARE USED FOR IMPORTANT SAFETY INFORMATION IN THIS DOCUMENT Complies with IEC 61851 Electric vehicle conductive charging system IEC 61851 1 2017 and IEC 61851 21 2 2018 C...

Page 8: ...hbands when working with electrical equipment This rule is very easy to forget especially when you are showing some electrical part pointing with metallic pencil Enclose all electric contacts and conductors so that no one can accidentally come into contact When it is necessary to handle equipment that is plugged in be sure hands are dry and when possible wear nonconductive gloves protective clothe...

Page 9: ...charging modes as specified in IEC 61851 Do not modify this unit If modified Circontrol will reject all responsibility and the warranty will be void The Charge point does not support the ventilation optional function described in IEC 61851 1 2017 clause 6 3 2 2 Do not use any adapter except those approved by the EV manufacturer Only socket outlet EV plug adapter is allowed Donotperformanyrepairoma...

Page 10: ...o be guaranteed at all times POWER SUPPLY LINE DIMENSIONING The dimensioning of the input power supply line of the Charge Point must be checked by a qualified electrician Note that several factors such as cable length between distribution board and Charge Point or the maximum output current of the Charge Point may influence the criteria of cable selection In such cases increasing the cable cross s...

Page 11: ...07 ...

Page 12: ...08 Wallbox eNext Series Installation Manual 3 What s included Charge Point Installation Manual 2 5 mm Allen wrench Identification label Not in the eNext Elite Model ...

Page 13: ...n lights 2 Colour Screen 3 RFID reader 4 Logo 5 Cable glands 6 Socket outlet 7 Wall support holes 8 Closing box holes 9 MID meter Only in eNext Elite model Plugs may vary depending on the model 1 2 3 8 5 7 7 7 8 5 6 6 9 4 ...

Page 14: ...10 Wallbox eNext Series Installation Manual 4 Dimensions in mm 39 335 315 200 335 ...

Page 15: ...11 Dimensions 168 52 5 105 230 52 5 62 5 34 34 62 5 39 5 255 20 5 ...

Page 16: ...installed on a wall This system has been tested on a concrete wall to be securely fixed in such conditions is recommended to use 3 x Inox A2 wall screws DIN 7982 Ø4 8x3 3 x plastic anchors 6x40 or 8x40 If the wall surface has different properties the screws and plastic anchors must be defined by a qualified installer Screw driver Driller Ratchet 2 5mm Allen Ratchet tool can be used to open close t...

Page 17: ... some space shall be reserved for usability maintenance and safety reasons The picture below shows the recommended minimum distances Dimensions in mm 300 1100 300 300 Please comply with your country regulations If recommendations are not followed as described Circontrol will reject all responsibility and the warranty will be void ...

Page 18: ...s Installation Manual B Opening Open the Wallbox using an Allen wrench Use the ratchet tool to open close in conditions that hinder access Screw DIN 7380 2 M4x14 INOX Sealing washer DIN 7712 4 8 14MM INOX 2 5mm Allen wrench ...

Page 19: ...15 C Positioning Drill the wall Drill bit M 6 8 Dimensions in mm 1100 255 230 115 ...

Page 20: ...16 Wallbox eNext Series Installation Manual D Fixing Place the unit on the previous pierced points and fix it with screws ...

Page 21: ... at least Type A and with a sensitivity of 30 mA or RCD type B with the same rating The gauge of this electric protections must be according to the current setup of the charge controller C fault current shall be measured by a RCD type B or a appropriate equipment that ensures the disconnection of the supply in case of DC fault current above 6 mA eNext Elite may be equipped with and integrated 6mA ...

Page 22: ...onnect the ground cable to the ground terminal block Make sure all screws are securely tightened at 1 5 Nm Terminal block maximum cross section 10mm2 S Type of cable allowed by the terminal block Copper Cu The three possible schemes are shown below 1 WIRING DIAGRAM WITH INTERNAL ELECTRIC PROTECTIONS In case that the installation needs protections upstream we highly recommend the option 2A in order...

Page 23: ...a single phase charger with any issue 2A WIRING DIAGRAM EXTERNAL ELECTRIC PROTECTIONS WITH FEEDBACK IN CASE OF WELDED CONTACT OR DC LEAKAGE In case of welded contact or DC leakage detection the external protections of the Main Circuit will trip The protections of the control board Aux Circuit will not trip and the active error will be reported as described on chapter 5 sections G and H L1 L2 L3 N ...

Page 24: ... single phase charger with any issue 2B WIRING DIAGRAM EXTERNAL ELECTRIC PROTECTIONS WITHOUT FEEDBACK IN CASE OF WELDED CONTACT OR DC LEAKAGE L N PE Protections L1 L2 L3 N PE Protections SINGLE PHASE Charge Point Connect to the 230VAC In case of welded contact or DC leakage detection the external protections will trip powering off the whole charger and the control board will not be able to report ...

Page 25: ...arge Points BeON is connected downstream of the main power switch and upstream of the main loads The BeON shall be connected to the port BOR1 on the PCB of the Charge Point 1 Location of the BOR1 in the eNext Charge Point 2 Location of the BOR1 in the eNext Elite Charge Point For further information please refer to the eNext User Manual and Home BeON manual BOR1 A B SNAP FERRITE 2S2 2S1 1S2 1S1 Si...

Page 26: ...pply The detector sends a signal to the Charge Point main PCB which stops the charge transaction by opening the inner relays This error is notified by 6 blinking red lights In order to restart the charge transaction unplug the EV When the beacon lights turn back to green it is possible to start another charge transaction Three phase power supply The detector sends a signal to a trip coil that trip...

Page 27: ...PCB inside the Charge Point When the jumper is removed a device outside of the Charge Point can be placed to control the charge transaction This device should close the contact START to allow the charge transaction If the contact is open the charge transaction wont be able to start BOR4 BOR4 JUMPER J7 NO JUMPER J7 DISABLED ENABLED 1 2 1 Location of the BOR4 in the eNext Charge Point 2 Location of ...

Page 28: ...ore starting the unit ELECTRICAL PROTECTIONS If the unit includes electrical protections rearm all of them CLOSING Place the sealing washers on the screws and then place them in the 5 points indicated on the Charge Point next page to close it Do not tight the screws yet CHECK THE BEACON LIGHTS All beacon lights should light properly Here s the reference OPERATION Check that no abnormal noise appea...

Page 29: ...URE Tighten the screws crosswise in the sequence shown below As a guideline the recommended assembly torque is 0 8 1Nm PREVENTIVE MAINTENANCE It is recommended to perform one preventive maintenance per year 1 5 2 3 4 ...

Page 30: ...humidity 5 to 100 Non condensing GENERAL DATA Beacon lights Frontal LED bar Display 3 5 colour screen RFID reader ISO IEC 14443A B FelicA ISO 15693 ISO 18092 Available connectors Type 1 Cable Type 2 Cable Type 2 Socket Charging mode Mode 3 IK08 in some components appended to the body ie beacon lights Only for eNext Elite model Equipment to be installed outdoor shall be provided with the Low Temper...

Page 31: ...2 Socket 32A 22kW 10mm2 Please check availability with your local supplier It is recommended 10mm2 if the installation doesn t require more than one circuit passing through the same cable gland and 6 if there is more than one additional circuit The final cross section shall be calculated by a qualified technician taking into account the specific conditions of installation CONNECTIVITY eNext Wirele...

Page 32: ...28 Wallbox eNext Series Installation Manual 7 ...

Page 33: ...29 Need help In case of any query or if further information is required please contact our Post Sales Department 34 937 362 940 34 937 362 941 support circontrol com circontrol com ...

Page 34: ...30 Wallbox eNext Series Installation Manual 8 ...

Page 35: ...31 Notes ...

Page 36: ...lation Manual CIRCONTROL WALLBOX ENEXT SERIES INSTALLATION MANUAL A comprehensive guide on how to install and verify your Wallbox eNext V3 8 August 2021 Scan me to download the User Manual CIRCONTROL S A ALL RIGHTS RESERVED R398 ...

Reviews: