Technical data
ELECTRICAL DATA
Power supply
1P+N+PE / 3P+N+PE
Input/Output voltage
/- 10% / /-10%
Frequency
50Hz / 60Hz
Protections (optional)
DC 6mA leakage detector (MCB/RCBO with shunt trip
is required to open the circuit)
1
Optional: RCBO: RCD Type A + MCB - includes shunt
trip
Optional: RCBO: RCD Type B + MCB - includes shunt
trip
Protection against
electric shock
Class II
MODEL*
CONNECTORS
BY DEFAULT
OUTPUT
CURRENT
OUTPUT
POWER
MINIMUM
CABLE CROSS
SECTION**
eNext S
Type 2 Socket
32A
7,4kW
6/10mm
2
eNext T
Type 2 Socket
32A
22kW
10mm
2
(*) Please check availability with your local supplier
(**) It is recommended 10mm
2
if the installation doesn't require more than one circuit
passing through the same cable gland, and 6 if there is more than one additional circuit.
The final cross section shall be calculated by a qualified technician taking into account the
specific conditions of installation
CONNECTIVITY eNext
Wireless communication
Bluetooth v4.2 + BLE
CONNECTIVITY eNext Elite
Ethernet
10/100BaseTX (TCP-IP)
Wi-Fi
2.4GHz (IEEE 802.11b/g/n)
Cellular*
Modem 4G / 3G / GPRS / GSM
Interface protocol
OCPP 1.6J
(
1
) The DC 6mA leakage detector comes by default in the eNext Elite model.
MCB complies with IEC 60898-1
RCD complies with IEC 62955
Summary of Contents for Wallbox eNext Series
Page 1: ...Installation Manual Wallbox eNext Series ...
Page 2: ...Wallbox eNext Series Installation Manual ...
Page 4: ...Wallbox eNext Series Installation Manual ...
Page 6: ...02 Wallbox eNext Series Installation Manual 1 ...
Page 11: ...07 ...
Page 14: ...10 Wallbox eNext Series Installation Manual 4 Dimensions in mm 39 335 315 200 335 ...
Page 15: ...11 Dimensions 168 52 5 105 230 52 5 62 5 34 34 62 5 39 5 255 20 5 ...
Page 19: ...15 C Positioning Drill the wall Drill bit M 6 8 Dimensions in mm 1100 255 230 115 ...
Page 32: ...28 Wallbox eNext Series Installation Manual 7 ...
Page 34: ...30 Wallbox eNext Series Installation Manual 8 ...
Page 35: ...31 Notes ...