Positioning User Manual
48
h)
Control Code Table
Code
Symbol
Function
Remark
Hex
Decimal
01H
1
ABS
Absolute position control
05H
5
INC
Incremental position control
09H
9
FEED
Incremental position control
after resetting current address
13H
19
FSC
Speed control (Forward)
17H
23
RSC
Speed control (Backward)
80H
128
NOP
No operation
81H
129
JUMP
Forced to change next step No.
Next step set value is stored in
‘target position address’
82H
130
LOOP
The first step of loop
Loop count is stored in ‘target
position address’
83H
131
LEND
The last step of loop
84H
132
POS
Forced to change the current
position address
New address is stored in ‘target