Positioning User Manual
21
1.6.5
Positioning Completed Flag
Positioning Completed Flag turns ON when a positioning operation is completed. Duration can be
configured by setting “Complete Output Signal Duration” in parameter.
1.6.6
OPR Completed Flag
OPR Completed Flag turns ON at the end of dwell time after OPR. Reset (OFF) condition is listed here.
When CPU changes to STOP mode.
When a new OPR operation begins.
When the axis gets disabled.
1.6.7
Direction Flag
Direction Flag indicates the rotation direction of the axis. (0 = Forward, 1 = Backward)
1.6.8
Disable Pulse Output
When an error occurs during the positioning operation, error code gets written in the memory offset 19.
At the same time, ‘Error’ and ‘Disable Pulse Output’ flags are set automatically. Pulse does not output
while the ‘Disable Pulse Output’ flag is set. To enable the pulse output, the source of the error should be
removed and the error code has to be cleared by setting the ‘Error Clear Request’ in the control flag.
1.6.9
Error Flag
If an error occurs during the operation of the corresponding axis, this ‘Error’ flag is set. The detailed
information on the error is found in the ‘Error Code.’ After removing the source of the error, this flag can
be cleared by using the POSCTRL instruction.