TRANSTIG 300 AC/DC
SERVICE MANUAL
4-2
June 30, 2008
3. Positive Terminal:
Welding current flows from
the Power Source via heavy duty Dinse type
terminal. It is essential, however, that the male
plug is inserted and turned securely to achieve a
sound electrical connection.
4. Negative Terminal:
Welding current flows from
the Power Source via heavy duty Dinse type
terminal. It is essential, however, that the male
plug is inserted and turned securely to achieve a
sound electrical connection.
CAUTION
Loose welding terminal connections can
cause overheating and result in the male
plug being fused in the bayonet terminal.
5. Gas Outlet:
Torch / Gas Terminal is an all-in-one
design of the Gas Outlet and the Negative Terminal.
Gas Outlet is a 5/8-18 UNF female gas fitting.
6. ON/OFF Switch:
This switch connects the Primary
supply voltage to the inverter when in the ON
position. This enables the Power Supply.
!
WARNING
When the welder is connected to the
Primary supply voltage, the internal
electrical components may be at 240V
potential with respect to earth.
7. Input Cable:
The input cable connects the Primary
supply voltage to the equipment.
8
.
Gas Inlet:
The Gas Inlet is a 5/8-18 UNF female gas
fitting.
Summary of Contents for TRANSTIG 300 AC/DC
Page 8: ......
Page 20: ...TRANSTIG 300 AC DC SERVICE MANUAL 2 6 June 30 2008 THIS PAGE LEFT INTENTIONALLY BLANK...
Page 34: ...TRANSTIG 300 AC DC SERVICE MANUAL 5 2 June 30 2008 NOTES...
Page 56: ...TRANSTIG 300 AC DC SERVICE MANUAL 11 2 June 30 2008 NOTES...
Page 78: ...THIS PAGE LEFT INTENTIONALLY BLANK TRANSTIG 300 AC DC SERVICE MANUAL 13 18 June 30 2008...
Page 125: ...THIS PAGE LEFT INTENTIONALLY BLANK TRANSTIG 300 AC DC SERVICE MANUAL June 30 2008 A 7...