TRANSTIG 220AC/DC AND 300AC/DC POWER SOURCE
INSTALLATION, OPERATION AND SETUP
3-6
Manual 0-5293
A-12034
Figure 3-3: 14 Pin Remote Control Socket
Socket Pin
Part Number / Description
1
Trigger Switch Input
2
Trigger Switch Input
3
Remote Control 5k ohm Potentiometers Maximum
4
Remote Control 5k ohm Potentiometers Wiper
5
Remote Control 5k ohm Potentiometers Minimum
6
Remote Control Enable (Short to common to enable remote control)
7
Common
8
Remote 2T (short to common to select remote control active in 2T operation mode only)
9
Volt free relay contact, Weld Amps > 0A
10
Volt free relay contact, Weld Amps > 0A
11
Not used
12
Not used
13
Not used
14
Not used
Table 3-2: 14 Pin Interconnection Control Plug Configuration
A-12035
Figure 3-4: Control Panel Weld Mode & Meter Displays