TRANSTIG 220AC/DC AND 300AC/DC POWER SOURCE
POWER SOURCE PROBLEMS AND ROUTINE SERVICE REQUIREMENTS 5-4 Manual 0-5293
C. Calibration Equipment
All equipment used for Power Source calibration shall be in proper working condition and be suitable for
conducting the measurement in question. Only test equipment with valid calibration certificates (NATA
certified laboratories) shall be utilized.
5.04 Cleaning the Welding Power Source
!
WARNING
There are dangerous voltage and power levels present inside this product. Do not attempt to open
or repair unless you are a qualified electrical tradesperson. Disconnect the Welding Power Source
from the Mains Supply Voltage before disassembling.
To clean the Welding Power Source, open the enclosure and use a vacuum cleaner to remove any accumulated
dirt, metal filings, slag and loose material. Keep the shunt and lead screw surfaces clean as accumulated foreign
material may reduce the welders output welding current.