40
CN 3960 Hardware Installation Guide
U
NIT
S
TATUS
LED
S
Unit Status LEDs
The unit status LEDs communicate system operational status. They are located to the left
of the faceplate as shown in
Figure 1-1, on page 5.
Figure A-1:
Unit status LEDs
Table A-1: Unit status LEDs, 3.0 System Software
LED
Indication
Description
PS A
Solid Green
Off
Power Supply A is active.
Power Supply inactive or not present.
PS B
Solid Green
Off
Power Supply B is active.
Power Supply inactive or not present.
STAT
Off
Solid Green
Blinking Green
System is not operating normally.
Indicates status normal/system ready.
System is initializing and performing self tests.
PWR
Solid Green
Turns on when power is applied and remains on until the system is
powered off.
ALRM
Off
Solid Yellow
Normal operating conditions.
An error has been detected.
TEMP
Off
Solid Yellow
System temperature is within the defined operating range.
Over temperature alarm condition present. The system
temperature has exceeded the operating temperature range.
PS A
STAT
ALRM
PS B
PWR
TEMP